Indoor/Outdoor relationships, trends, and carbonaceous content of fine particulate matter in retirement homes of the Los Angeles Basin - PubMed (original) (raw)
Indoor/Outdoor relationships, trends, and carbonaceous content of fine particulate matter in retirement homes of the Los Angeles Basin
Andrea Polidori et al. J Air Waste Manag Assoc. 2007 Mar.
Abstract
Hourly indoor and outdoor fine particulate matter (PM2.5), organic and elemental carbon (OC and EC, respectively), particle number (PN), ozone (O3), carbon monoxide (CO), and nitrogen oxide (NOx) concentrations were measured at two different retirement communities in the Los Angeles, CA, area as part of the Cardiovascular Health and Air Pollution Study. Site A (group 1 [G1]) was operated from July 6 to August 20, 2005 (phase 1 [P1]) and from October 19 to December 10, 2005 (P2), whereas site B (group 2 [G2]) was operated from August 24 to October 15, 2005 (P1), and from January 4 to February 18, 2006 (P2). Overall, the magnitude of indoor and outdoor measurements was similar, probably because of the major influence of outdoor sources on indoor particle and gas levels. However, G2 showed a substantial increase in indoor OC, PN, and PM2.5 between 6:00 and 9:00 a.m., probably from cooking. The contributions of primary and secondary OC (SOA) to measured outdoor OC were estimated from collected OC and EC concentrations using EC as a tracer of primary combustion-generated OC (i.e., "EC tracer method"). The study average outdoor SOA accounted for 40% of outdoor particulate OC (40-45% in the summer and 32-40% in the winter). Air exchange rates (hr(-1)) and infiltration factors (Finf; dimensionless) at each site were also determined. Estimated Finf and measured particle concentrations were then used in a single compartment mass balance model to assess the contributions of indoor and/or outdoor sources to measured indoor OC, EC, PM2.5, and PN. The average percentage contributions of indoor SOA of outdoor origin to measured indoor OC were approximately 35% (during G1P1 and G1P2) and approximately 45% (for G2P1 and G2P2). On average, 36% (G2P1) to 44% (G1P1) of measured indoor OC was composed of outdoor-generated primary OC.
Similar articles
- Relationships of Indoor, Outdoor, and Personal Air (RIOPA): part II. Analyses of concentrations of particulate matter species.
Turpin BJ, Weisel CP, Morandi M, Colome S, Stock T, Eisenreich S, Buckley B. Turpin BJ, et al. Res Rep Health Eff Inst. 2007 Aug;(130 Pt 2):1-77; discussion 79-92. Res Rep Health Eff Inst. 2007. PMID: 18064946 - Chemical characterization and source apportionment of indoor and outdoor fine particulate matter (PM(2.5)) in retirement communities of the Los Angeles Basin.
Hasheminassab S, Daher N, Shafer MM, Schauer JJ, Delfino RJ, Sioutas C. Hasheminassab S, et al. Sci Total Environ. 2014 Aug 15;490:528-37. doi: 10.1016/j.scitotenv.2014.05.044. Epub 2014 May 28. Sci Total Environ. 2014. PMID: 24880542 Free PMC article. - Fine organic particulate matter dominates indoor-generated PM2.5 in RIOPA homes.
Polidori A, Turpin B, Meng QY, Lee JH, Weisel C, Morandi M, Colome S, Stock T, Winer A, Zhang J, Kwon J, Alimokhtari S, Shendell D, Jones J, Farrar C, Maberti S. Polidori A, et al. J Expo Sci Environ Epidemiol. 2006 Jul;16(4):321-31. doi: 10.1038/sj.jes.7500476. Epub 2006 Mar 15. J Expo Sci Environ Epidemiol. 2006. PMID: 16538235 - The Adverse Effects of Air Pollution on the Eye: A Review.
Lin CC, Chiu CC, Lee PY, Chen KJ, He CX, Hsu SK, Cheng KC. Lin CC, et al. Int J Environ Res Public Health. 2022 Jan 21;19(3):1186. doi: 10.3390/ijerph19031186. Int J Environ Res Public Health. 2022. PMID: 35162209 Free PMC article. Review. - Indoor PM2.5 removal efficiency of two different non-thermal plasma systems.
Hernández-Díaz D, Martos-Ferreira D, Hernández-Abad V, Villar-Ribera R, Tarrés Q, Rojas-Sola JI. Hernández-Díaz D, et al. J Environ Manage. 2021 Jan 15;278(Pt 1):111515. doi: 10.1016/j.jenvman.2020.111515. Epub 2020 Oct 24. J Environ Manage. 2021. PMID: 33113396 Review.
Cited by
- Air pollution exposures and circulating biomarkers of effect in a susceptible population: clues to potential causal component mixtures and mechanisms.
Delfino RJ, Staimer N, Tjoa T, Gillen DL, Polidori A, Arhami M, Kleinman MT, Vaziri ND, Longhurst J, Sioutas C. Delfino RJ, et al. Environ Health Perspect. 2009 Aug;117(8):1232-8. doi: 10.1289/ehp.0800194. Epub 2009 Apr 29. Environ Health Perspect. 2009. PMID: 19672402 Free PMC article. - Electrocardiographic ST-segment depression and exposure to traffic-related aerosols in elderly subjects with coronary artery disease.
Delfino RJ, Gillen DL, Tjoa T, Staimer N, Polidori A, Arhami M, Sioutas C, Longhurst J. Delfino RJ, et al. Environ Health Perspect. 2011 Feb;119(2):196-202. doi: 10.1289/ehp.1002372. Epub 2010 Oct 21. Environ Health Perspect. 2011. PMID: 20965803 Free PMC article. - Relation of whole blood carboxyhemoglobin concentration to ambient carbon monoxide exposure estimated using regression.
Rudra CB, Williams MA, Sheppard L, Koenig JQ, Schiff MA, Frederick IO, Dills R. Rudra CB, et al. Am J Epidemiol. 2010 Apr 15;171(8):942-51. doi: 10.1093/aje/kwq022. Epub 2010 Mar 22. Am J Epidemiol. 2010. PMID: 20308199 Free PMC article. - Estimating mortality derived from indoor exposure to particles of outdoor origin.
Ji W, Zhao B. Ji W, et al. PLoS One. 2015 Apr 10;10(4):e0124238. doi: 10.1371/journal.pone.0124238. eCollection 2015. PLoS One. 2015. PMID: 25860147 Free PMC article. Review. - Development and performance evaluation of online monitors for near real-time measurement of total and water-soluble organic carbon in fine and coarse ambient PM.
Aghaei Y, Aldekheel M, Tohidi R, Badami MM, Farahani VJ, Sioutas C. Aghaei Y, et al. Atmos Environ (1994). 2024 Feb 15;319:120316. doi: 10.1016/j.atmosenv.2023.120316. Epub 2023 Dec 23. Atmos Environ (1994). 2024. PMID: 38250566
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous