Fatigue is more damaging than creep in ligament revealed by modulus reduction and residual strength - PubMed (original) (raw)
. 2007 Oct;35(10):1713-21.
doi: 10.1007/s10439-007-9349-z. Epub 2007 Jul 14.
Affiliations
- PMID: 17629791
- DOI: 10.1007/s10439-007-9349-z
Fatigue is more damaging than creep in ligament revealed by modulus reduction and residual strength
Gail M Thornton et al. Ann Biomed Eng. 2007 Oct.
Abstract
Following injury of a complementary joint restraint, ligaments can be subjected to higher than normal stresses. Normal ligaments are exposed to static (creep) and cyclic (fatigue) loading from which damage can accumulate at these higher than normal stresses. This study tracked damage accumulation during creep and fatigue loading of normal rabbit medial collateral ligaments (MCLs) over a range of stresses, using modulus reduction as a marker of damage. Creep tests were interrupted occasionally with unloading/reloading cycles to measure modulus. Test stresses were normalized to ultimate tensile strength (UTS): 60%, 30%, and 15% UTS. Not all creep and fatigues tests progressed until rupture but were stopped and followed by an assessment of the residual strength of that partially damaged ligament using a monotonic failure test. Fatigue loading caused earlier modulus reduction than creep. Modulus reduction occurred at lower increases in strain (strain relative to initial strain) for fatigue than creep. In other words, at the same time or increase in strain, fatigue is more damaging than creep because the modulus ratio reduction is greater. These findings suggest that creep and fatigue have different strain and damage mechanisms. Ligaments exposed to creep or fatigue loading which produced a modulus reduction had decreased residual strength and increased toe-region strain in a subsequent monotonic failure test. This finding confirmed that modulus reduction during creep and fatigue is a suitable marker of partial damage in ligament. Cyclic loading caused damage earlier than static loading, likely an important consideration when ligaments are loaded to higher than normal magnitudes following injury of a complementary joint restraint.
Similar articles
- Cyclic loading causes faster rupture and strain rate than static loading in medial collateral ligament at high stress.
Thornton GM, Schwab TD, Oxland TR. Thornton GM, et al. Clin Biomech (Bristol). 2007 Oct;22(8):932-40. doi: 10.1016/j.clinbiomech.2007.05.004. Epub 2007 Jun 28. Clin Biomech (Bristol). 2007. PMID: 17602807 - Sensory-motor control of ligaments and associated neuromuscular disorders.
Solomonow M. Solomonow M. J Electromyogr Kinesiol. 2006 Dec;16(6):549-67. doi: 10.1016/j.jelekin.2006.08.004. Epub 2006 Oct 11. J Electromyogr Kinesiol. 2006. PMID: 17045488 Review. - [Cardiovascular physiology. Elasticity and viscoelasticity of the circulatory system. I. Physical basis. II. Arteries].
Bettencourt MJ. Bettencourt MJ. Rev Port Cardiol. 1994 Apr;13(4):337-54,292. Rev Port Cardiol. 1994. PMID: 7917383 Review. Portuguese.
Cited by
- Static loading of the knee joint results in modified single leg landing biomechanics.
Olson MW. Olson MW. PLoS One. 2020 Feb 21;15(2):e0219648. doi: 10.1371/journal.pone.0219648. eCollection 2020. PLoS One. 2020. PMID: 32084138 Free PMC article. - Subrupture tendon fatigue damage.
Fung DT, Wang VM, Laudier DM, Shine JH, Basta-Pljakic J, Jepsen KJ, Schaffler MB, Flatow EL. Fung DT, et al. J Orthop Res. 2009 Feb;27(2):264-273. doi: 10.1002/jor.20722. J Orthop Res. 2009. PMID: 18683881 Free PMC article. - Time-dependent damage in predictions of fatigue behaviour of normal and healing ligaments.
Thornton GM, Bailey SJ, Schwab TD. Thornton GM, et al. Mech Time Depend Mater. 2015;19(3):335-349. doi: 10.1007/s11043-015-9267-7. Epub 2015 Jun 10. Mech Time Depend Mater. 2015. PMID: 30174542 Free PMC article. - Fatigue damage of collagenous tissues: experiment, modeling and simulation studies.
Martin C, Sun W. Martin C, et al. J Long Term Eff Med Implants. 2015;25(1-2):55-73. doi: 10.1615/jlongtermeffmedimplants.2015011749. J Long Term Eff Med Implants. 2015. PMID: 25955007 Free PMC article. Review. - Development and evaluation of ligament phantoms targeted for shear wave tensiometry.
Arant LR, Roth JD. Arant LR, et al. J Mech Behav Biomed Mater. 2022 Feb;126:104984. doi: 10.1016/j.jmbbm.2021.104984. Epub 2021 Nov 24. J Mech Behav Biomed Mater. 2022. PMID: 34857491 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources