Serum anion gap: its uses and limitations in clinical medicine - PubMed (original) (raw)
Review
doi: 10.2215/CJN.03020906. Epub 2006 Dec 6.
Affiliations
- PMID: 17699401
- DOI: 10.2215/CJN.03020906
Review
Serum anion gap: its uses and limitations in clinical medicine
Jeffrey A Kraut et al. Clin J Am Soc Nephrol. 2007 Jan.
Abstract
The serum anion gap, calculated from the electrolytes measured in the chemical laboratory, is defined as the sum of serum chloride and bicarbonate concentrations subtracted from the serum sodium concentration. This entity is used in the detection and analysis of acid-base disorders, assessment of quality control in the chemical laboratory, and detection of such disorders as multiple myeloma, bromide intoxication, and lithium intoxication. The normal value can vary widely, reflecting both differences in the methods that are used to measure its constituents and substantial interindividual variability. Low values most commonly indicate laboratory error or hypoalbuminemia but can denote the presence of a paraproteinemia or intoxication with lithium, bromide, or iodide. Elevated values most commonly indicate metabolic acidosis but can reflect laboratory error, metabolic alkalosis, hyperphosphatemia, or paraproteinemia. Metabolic acidosis can be divided into high anion and normal anion gap varieties, which can be present alone or concurrently. A presumed 1:1 stoichiometry between change in the serum anion gap (DeltaAG) and change in the serum bicarbonate concentration (DeltaHCO(3)(-)) has been used to uncover the concurrence of mixed metabolic acid-base disorders in patients with high anion gap acidosis. However, recent studies indicate variability in the DeltaAG/DeltaHCO(3)(-) in this disorder. This observation undercuts the ability to use this ratio alone to detect complex acid-base disorders, thus emphasizing the need to consider additional information to obtain the appropriate diagnosis. Despite these caveats, calculation of the serum anion gap remains an inexpensive and effective tool that aids detection of various acid-base disorders, hematologic malignancies, and intoxications.
Similar articles
- Use of the DeltaAG/DeltaHCO3- ratio in the diagnosis of mixed acid-base disorders.
Rastegar A. Rastegar A. J Am Soc Nephrol. 2007 Sep;18(9):2429-31. doi: 10.1681/ASN.2006121408. Epub 2007 Jul 26. J Am Soc Nephrol. 2007. PMID: 17656477 Review. - [What is the contribution of Stewart's concept in acid-base disorders analysis?].
Quintard H, Hubert S, Ichai C. Quintard H, et al. Ann Fr Anesth Reanim. 2007 May;26(5):423-33. doi: 10.1016/j.annfar.2007.02.012. Epub 2007 Apr 25. Ann Fr Anesth Reanim. 2007. PMID: 17462852 Review. French. - Gaps in the anion gap.
Salem MM, Mujais SK. Salem MM, et al. Arch Intern Med. 1992 Aug;152(8):1625-9. Arch Intern Med. 1992. PMID: 1497396 Review. - Approach to patients with acid-base disorders.
Kraut JA, Madias NE. Kraut JA, et al. Respir Care. 2001 Apr;46(4):392-403. Respir Care. 2001. PMID: 11262558 Review. - Diagnosing metabolic acidosis in the critically ill: bridging the anion gap, Stewart, and base excess methods.
Fidkowski C, Helstrom J. Fidkowski C, et al. Can J Anaesth. 2009 Mar;56(3):247-56. doi: 10.1007/s12630-008-9037-y. Epub 2009 Feb 13. Can J Anaesth. 2009. PMID: 19247746 Review.
Cited by
- The association between serum anion gap and acute kidney injury after coronary artery bypass grafting in patients with acute coronary syndrome.
Pan Q, Mu Z, Li Y, Gu C, Liu T, Wang B, Kang X. Pan Q, et al. BMC Cardiovasc Disord. 2023 Nov 8;23(1):542. doi: 10.1186/s12872-023-03588-y. BMC Cardiovasc Disord. 2023. PMID: 37940847 Free PMC article. - The serum anion gap is altered in early kidney disease and associates with mortality.
Abramowitz MK, Hostetter TH, Melamed ML. Abramowitz MK, et al. Kidney Int. 2012 Sep;82(6):701-9. doi: 10.1038/ki.2012.196. Epub 2012 May 23. Kidney Int. 2012. PMID: 22622500 Free PMC article. - Ion-selective electrode and anion gap range: What should the anion gap be?
Sadjadi SA, Manalo R, Jaipaul N, McMillan J. Sadjadi SA, et al. Int J Nephrol Renovasc Dis. 2013 Jun 7;6:101-5. doi: 10.2147/IJNRD.S44689. Print 2013. Int J Nephrol Renovasc Dis. 2013. PMID: 23776389 Free PMC article. - Automatic real-time analysis and interpretation of arterial blood gas sample for Point-of-care testing: Clinical validation.
Rodríguez-Villar S, Poza-Hernández P, Freigang S, Zubizarreta-Ormazabal I, Paz-Martín D, Holl E, Pérez-Pardo OC, Tovar-Doncel MS, Wissa SM, Cimadevilla-Calvo B, Tejón-Pérez G, Moreno-Fernández I, Escario-Méndez A, Arévalo-Serrano J, Valentín A, Do-Vale BM, Fletcher HM, Lorenzo-Fernández JM. Rodríguez-Villar S, et al. PLoS One. 2021 Mar 10;16(3):e0248264. doi: 10.1371/journal.pone.0248264. eCollection 2021. PLoS One. 2021. PMID: 33690724 Free PMC article. - The Δ Anion Gap/Δ Bicarbonate Ratio in Lactic Acidosis: Time for a New Baseline?
Lu D, Song H, Amy Liu IL, Shi J, Treger RM. Lu D, et al. Kidney360. 2024 Sep 1;5(9):1251-1261. doi: 10.34067/KID.0000000000000513. Epub 2024 Jul 22. Kidney360. 2024. PMID: 39037810 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous