A quality assurance phantom for the performance evaluation of volumetric micro-CT systems
Louise Y Du et al. Phys Med Biol. 2007.
Abstract
Small-animal imaging has recently become an area of increased interest because more human diseases can be modeled in transgenic and knockout rodents. As a result, micro-computed tomography (micro-CT) systems are becoming more common in research laboratories, due to their ability to achieve spatial resolution as high as 10 microm, giving highly detailed anatomical information. Most recently, a volumetric cone-beam micro-CT system using a flat-panel detector (eXplore Ultra, GE Healthcare, London, ON) has been developed that combines the high resolution of micro-CT and the fast scanning speed of clinical CT, so that dynamic perfusion imaging can be performed in mice and rats, providing functional physiological information in addition to anatomical information. This and other commercially available micro-CT systems all promise to deliver precise and accurate high-resolution measurements in small animals. However, no comprehensive quality assurance phantom has been developed to evaluate the performance of these micro-CT systems on a routine basis. We have designed and fabricated a single comprehensive device for the purpose of performance evaluation of micro-CT systems. This quality assurance phantom was applied to assess multiple image-quality parameters of a current flat-panel cone-beam micro-CT system accurately and quantitatively, in terms of spatial resolution, geometric accuracy, CT number accuracy, linearity, noise and image uniformity. Our investigations show that 3D images can be obtained with a limiting spatial resolution of 2.5 mm(-1) and noise of +/-35 HU, using an acquisition interval of 8 s at an entrance dose of 6.4 cGy.
Similar articles
- Combined system of fluorescence diffuse optical tomography and microcomputed tomography for small animal imaging.
Yang X, Gong H, Quan G, Deng Y, Luo Q. Yang X, et al. Rev Sci Instrum. 2010 May;81(5):054304. doi: 10.1063/1.3422252. Rev Sci Instrum. 2010. PMID: 20515159 - Physical evaluation of the weighted Feldkamp algorithms applied to the 256-detector row CT scanner for volumetric cine imaging.
Mori S, Endo M, Kondo C, Tanada S. Mori S, et al. Acad Radiol. 2006 Jun;13(6):701-12. doi: 10.1016/j.acra.2006.03.002. Acad Radiol. 2006. PMID: 16679272 - Flat panel detector-based cone-beam volume CT angiography imaging: system evaluation.
Ning R, Chen B, Yu R, Conover D, Tang X, Ning Y. Ning R, et al. IEEE Trans Med Imaging. 2000 Sep;19(9):949-63. doi: 10.1109/42.887842. IEEE Trans Med Imaging. 2000. PMID: 11127608 - X-ray computed tomography.
Kalender WA. Kalender WA. Phys Med Biol. 2006 Jul 7;51(13):R29-43. doi: 10.1088/0031-9155/51/13/R03. Epub 2006 Jun 20. Phys Med Biol. 2006. PMID: 16790909 Review. - Molecular imaging in small animals--roles for micro-CT.
Ritman EL. Ritman EL. J Cell Biochem Suppl. 2002;39:116-24. doi: 10.1002/jcb.10415. J Cell Biochem Suppl. 2002. PMID: 12552611 Review.
Cited by
- Ex vivo coronary calcium volume quantification using a high-spatial-resolution clinical photon-counting-detector computed tomography.
Marsh JF Jr, VanMeter PD, Rajendran K, Leng S, McCollough CH. Marsh JF Jr, et al. J Med Imaging (Bellingham). 2023 Jul;10(4):043501. doi: 10.1117/1.JMI.10.4.043501. Epub 2023 Jul 4. J Med Imaging (Bellingham). 2023. PMID: 37408984 Free PMC article. - From Nanothermometry to Bioimaging: Lanthanide-Activated KY3F10 Nanostructures as Biocompatible Multifunctional Tools for Nanomedicine.
Cressoni C, Vurro F, Milan E, Muccilli M, Mazzer F, Gerosa M, Boschi F, Spinelli AE, Badocco D, Pastore P, Delgado NF, Collado MH, Marzola P, Speghini A. Cressoni C, et al. ACS Appl Mater Interfaces. 2023 Mar 8;15(9):12171-12188. doi: 10.1021/acsami.2c22000. Epub 2023 Feb 24. ACS Appl Mater Interfaces. 2023. PMID: 36826830 Free PMC article. - GeoBioMed perspectives on kidney stone recurrence from the reactive surface area of SWL-derived particles.
Todorov LG, Sivaguru M, Krambeck AE, Lee MS, Lieske JC, Fouke BW. Todorov LG, et al. Sci Rep. 2022 Nov 1;12(1):18371. doi: 10.1038/s41598-022-23331-5. Sci Rep. 2022. PMID: 36319741 Free PMC article. - Cost-effective micro-CT system for non-destructive testing of titanium 3D printed medical components.
Cobos SF, Norley CJ, Pollmann SI, Holdsworth DW. Cobos SF, et al. PLoS One. 2022 Oct 10;17(10):e0275732. doi: 10.1371/journal.pone.0275732. eCollection 2022. PLoS One. 2022. PMID: 36215251 Free PMC article. - Antiosteoporosis effect of tanshinol in osteoporosis animal models: A systematic review and meta-analysis.
Wang S, Yuan Y, Lin Q, Zhou H, Tang B, Liu Y, Huang H, Liang B, Mao Y, Liu K, Shi X. Wang S, et al. Front Pharmacol. 2022 Aug 10;13:937538. doi: 10.3389/fphar.2022.937538. eCollection 2022. Front Pharmacol. 2022. PMID: 36034813 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous