A dual echo approach to removing motion artefacts in fMRI time series
Pieter F Buur et al. NMR Biomed. 2009 Jun.
Abstract
In fMRI, subject motion can severely affect data quality. This is a particular problem when movement is correlated with the experimental paradigm as this potentially causes artefactual activation. A method is presented that uses linear regression, to utilise the time course of an image acquired at very short echo time (TE) as a voxel-wise regressor for a second image in the same echo train, that is acquired with high BOLD sensitivity. The value of this approach is demonstrated using task-locked motion combined with visual stimulation. Results obtained at both 1.5 and 3 T show improvements in functional activation maps for individual subjects. The method is straightforward to implement, does not require extra scan time and can easily be embedded in a multi-echo acquisition framework.
2009 John Wiley & Sons, Ltd.
Similar articles
- Image distortion correction in fMRI: A quantitative evaluation.
Hutton C, Bork A, Josephs O, Deichmann R, Ashburner J, Turner R. Hutton C, et al. Neuroimage. 2002 May;16(1):217-40. doi: 10.1006/nimg.2001.1054. Neuroimage. 2002. PMID: 11969330 - Investigating the benefits of multi-echo EPI for fMRI at 7 T.
Poser BA, Norris DG. Poser BA, et al. Neuroimage. 2009 May 1;45(4):1162-72. doi: 10.1016/j.neuroimage.2009.01.007. Epub 2009 Jan 21. Neuroimage. 2009. PMID: 19349231 - Movement artefacts and MR BOLD signal increase during different paradigms for mapping the sensorimotor cortex.
Hoeller M, Krings T, Reinges MH, Hans FJ, Gilsbach JM, Thron A. Hoeller M, et al. Acta Neurochir (Wien). 2002 Mar;144(3):279-84; discussion 284. doi: 10.1007/s007010200036. Acta Neurochir (Wien). 2002. PMID: 11956941 - Improved functional mapping of the human amygdala using a standard functional magnetic resonance imaging sequence with simple modifications.
Morawetz C, Holz P, Lange C, Baudewig J, Weniger G, Irle E, Dechent P. Morawetz C, et al. Magn Reson Imaging. 2008 Jan;26(1):45-53. doi: 10.1016/j.mri.2007.04.014. Epub 2007 Jun 18. Magn Reson Imaging. 2008. PMID: 17574366
Cited by
- Denoising task-correlated head motion from motor-task fMRI data with multi-echo ICA.
Reddy NA, Zvolanek KM, Moia S, Caballero-Gaudes C, Bright MG. Reddy NA, et al. Imaging Neurosci (Camb). 2024;2:10.1162/imag_a_00057. doi: 10.1162/imag_a_00057. Epub 2024 Jan 5. Imaging Neurosci (Camb). 2024. PMID: 39328846 Free PMC article. - Denoising task-correlated head motion from motor-task fMRI data with multi-echo ICA.
Reddy NA, Zvolanek KM, Moia S, Caballero-Gaudes C, Bright MG. Reddy NA, et al. bioRxiv [Preprint]. 2023 Nov 1:2023.07.19.549746. doi: 10.1101/2023.07.19.549746. bioRxiv. 2023. PMID: 37503125 Free PMC article. Updated. Preprint. - Resting State fMRI: Going Through the Motions.
Maknojia S, Churchill NW, Schweizer TA, Graham SJ. Maknojia S, et al. Front Neurosci. 2019 Aug 13;13:825. doi: 10.3389/fnins.2019.00825. eCollection 2019. Front Neurosci. 2019. PMID: 31456656 Free PMC article. Review. - A deconvolution algorithm for multi-echo functional MRI: Multi-echo Sparse Paradigm Free Mapping.
Caballero-Gaudes C, Moia S, Panwar P, Bandettini PA, Gonzalez-Castillo J. Caballero-Gaudes C, et al. Neuroimage. 2019 Nov 15;202:116081. doi: 10.1016/j.neuroimage.2019.116081. Epub 2019 Aug 13. Neuroimage. 2019. PMID: 31419613 Free PMC article. - Attention-Related Brain Activation Is Altered in Older Adults With White Matter Hyperintensities Using Multi-Echo fMRI.
Atwi S, Metcalfe AWS, Robertson AD, Rezmovitz J, Anderson ND, MacIntosh BJ. Atwi S, et al. Front Neurosci. 2018 Oct 18;12:748. doi: 10.3389/fnins.2018.00748. eCollection 2018. Front Neurosci. 2018. PMID: 30405336 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical