Measurement and quality control issues in multiplex protein assays: a case study - PubMed (original) (raw)
Measurement and quality control issues in multiplex protein assays: a case study
Allison A Ellington et al. Clin Chem. 2009 Jun.
Abstract
Background: Multiplex arrays are increasingly used for measuring protein biomarkers. Advantages of this approach include specimen conservation, limited sample handling, and decreased time and cost, but the challenges of optimizing assay format for each protein, selecting common dilution factors, and establishing robust quality control algorithms are substantial. Here, we use measurements of 15 protein biomarkers from a large study to illustrate processing, analytic, and quality control issues with multiplexed immunoassays.
Methods: We contracted with ThermoScientific for duplicate measurements of 15 proteins in 2322 participants from a community-based cohort, a plasma control, and recombinant protein controls using 2 custom planar microarrays with 6 (panel A) or 9 (panel B) capture antibodies printed in each well. We selected constituent analytes in each panel based on endogenous concentrations and assay availability. Protocols were standardized for sample processing, storage, and freeze-thaw exposures. We analyzed data for effects of deviations from processing protocols, precision, and bias.
Results: Measurements were within reportable ranges for each of the assays; however, concentrations for 7 of the 15 proteins were not centered on the dose-response curves. An additional freeze-thaw cycle and erroneous sample dilution for a subset of samples produced significantly different results. Measurements with large differences between duplicates were seen to cluster by analyte, plate, and participant. Conventional univariate quality control algorithms rejected many plates. Plate-specific medians of cohort and plasma control data significantly covaried, an observation important for development of alternative quality control algorithms.
Conclusions: Multiplex measurements present difficult challenges that require further analytical and statistical developments.
Figures
Fig. 1. Representative dose–response curves
Vertical dotted lines demark the 5th and 95th percentiles of cohort data. Arrows, squares, triangles, and diamonds depict the median values of the plasma control, recombinant protein quality control 1 (QC1), recombinant protein QC2, and recombinant protein QC3, respectively.
Fig. 2. (A), (B), and (C) illustrate the covariance of plate-specific population-normalized cohort means and plasma control means across 66 microplates for 3 representative proteins
Comment in
- Quality control and protein microarrays.
Kricka LJ, Master SR. Kricka LJ, et al. Clin Chem. 2009 Jun;55(6):1053-5. doi: 10.1373/clinchem.2009.126557. Epub 2009 Apr 24. Clin Chem. 2009. PMID: 19395435 No abstract available.
Similar articles
- Performance of multiplex cytokine assays in serum and saliva among community-dwelling postmenopausal women.
Browne RW, Kantarci A, LaMonte MJ, Andrews CA, Hovey KM, Falkner KL, Cekici A, Stephens D, Genco RJ, Scannapieco FA, Van Dyke TE, Wactawski-Wende J. Browne RW, et al. PLoS One. 2013;8(4):e59498. doi: 10.1371/journal.pone.0059498. Epub 2013 Apr 5. PLoS One. 2013. PMID: 23577067 Free PMC article. - Antibody-based protein multiplex platforms: technical and operational challenges.
Ellington AA, Kullo IJ, Bailey KR, Klee GG. Ellington AA, et al. Clin Chem. 2010 Feb;56(2):186-93. doi: 10.1373/clinchem.2009.127514. Epub 2009 Dec 3. Clin Chem. 2010. PMID: 19959625 Free PMC article. Review. - Analytical performance of a commercial multiplex Luminex-based cytokine panel in the rat.
Erkens T, Goeminne N, Kegels A, Byloos M, Vinken P. Erkens T, et al. J Pharmacol Toxicol Methods. 2018 May-Jun;91:43-49. doi: 10.1016/j.vascn.2018.01.005. Epub 2018 Jan 31. J Pharmacol Toxicol Methods. 2018. PMID: 29371052 - Recommendations for Use and Fit-for-Purpose Validation of Biomarker Multiplex Ligand Binding Assays in Drug Development.
Jani D, Allinson J, Berisha F, Cowan KJ, Devanarayan V, Gleason C, Jeromin A, Keller S, Khan MU, Nowatzke B, Rhyne P, Stephen L. Jani D, et al. AAPS J. 2016 Jan;18(1):1-14. doi: 10.1208/s12248-015-9820-y. Epub 2015 Sep 16. AAPS J. 2016. PMID: 26377333 Free PMC article. Review. - An evaluation of multiplex bead-based analysis of cytokines and soluble proteins in archived lithium heparin plasma, EDTA plasma and serum samples.
Brøndum L, Sørensen BS, Eriksen JG, Mortensen LS, Lønbro S, Overgaard J, Alsner J. Brøndum L, et al. Scand J Clin Lab Invest. 2016 Dec;76(8):601-611. doi: 10.1080/00365513.2016.1230882. Epub 2016 Sep 26. Scand J Clin Lab Invest. 2016. PMID: 27666533
Cited by
- Advancing Microfluidic Immunity Testing Systems: New Trends for Microbial Pathogen Detection.
Wang Y, Chen J, Zhang Y, Yang Z, Zhang K, Zhang D, Zheng L. Wang Y, et al. Molecules. 2024 Jul 15;29(14):3322. doi: 10.3390/molecules29143322. Molecules. 2024. PMID: 39064900 Free PMC article. Review. - ELISA in the multiplex era: potentials and pitfalls.
Tighe PJ, Ryder RR, Todd I, Fairclough LC. Tighe PJ, et al. Proteomics Clin Appl. 2015 Apr;9(3-4):406-22. doi: 10.1002/prca.201400130. Epub 2015 Mar 25. Proteomics Clin Appl. 2015. PMID: 25644123 Free PMC article. Review. - Performance of multiplex cytokine assays in serum and saliva among community-dwelling postmenopausal women.
Browne RW, Kantarci A, LaMonte MJ, Andrews CA, Hovey KM, Falkner KL, Cekici A, Stephens D, Genco RJ, Scannapieco FA, Van Dyke TE, Wactawski-Wende J. Browne RW, et al. PLoS One. 2013;8(4):e59498. doi: 10.1371/journal.pone.0059498. Epub 2013 Apr 5. PLoS One. 2013. PMID: 23577067 Free PMC article. - Antibody-based protein multiplex platforms: technical and operational challenges.
Ellington AA, Kullo IJ, Bailey KR, Klee GG. Ellington AA, et al. Clin Chem. 2010 Feb;56(2):186-93. doi: 10.1373/clinchem.2009.127514. Epub 2009 Dec 3. Clin Chem. 2010. PMID: 19959625 Free PMC article. Review. - Development and validation of protein microarray technology for simultaneous inflammatory mediator detection in human sera.
Selvarajah S, Negm OH, Hamed MR, Tubby C, Todd I, Tighe PJ, Harrison T, Fairclough LC. Selvarajah S, et al. Mediators Inflamm. 2014;2014:820304. doi: 10.1155/2014/820304. Epub 2014 Oct 14. Mediators Inflamm. 2014. PMID: 25382942 Free PMC article.
References
- van’t Veer LJDH, van de Vijver MJ, He YD, Hart AA, Mao M, Peterse HL, et al. Gene expression profiling predicts clinical outcome of breast cancer. Nature (Lond) 2002;415:530–6. - PubMed
- Rifai N, Gillette MA, Carr SA. Protein biomarker discovery and validation: the long and uncertain path to clinical utility. Nat Biotechnol. 2006;24:971–83. - PubMed
- Schweitzer B, Kingsmore SF. Measuring proteins on microarrays. Curr Opin Biotechnol. 2002;13:14–9. - PubMed
- Endogen SearchLight. [Accessed November 2008]. http://www.endogen.com/services/
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources