Comparative SNR for high-throughput mouse embryo MR microscopy - PubMed (original) (raw)
Comparative Study
doi: 10.1002/mrm.22352.
Affiliations
- PMID: 20512875
- DOI: 10.1002/mrm.22352
Free article
Comparative Study
Comparative SNR for high-throughput mouse embryo MR microscopy
Xiaoli Zhang et al. Magn Reson Med. 2010 Jun.
Free article
Abstract
MR microscopy is being explored as a useful imaging tool to phenotype mouse embryos due to its volume coverage with three-dimensional isotropic resolution. However, the main limitation for mouse embryo MR microscopy is the signal-to-noise ratio. Large numbers of embryos are needed for phenotypic screening, making high throughput essential. Two high-throughput imaging approaches, multi-embryo shared-coil (shared) and multi-embryo individual-coil (individual), have been developed for phenotyping mouse embryos. This study quantitatively compares the signal-to-noise ratio at equivalent times between these two established methods by compensating for differences that result from field strength. While the individual method provides 3.3 times as much signal-to-noise ratio as the shared method at equivalent conditions, it is more difficult and expensive to implement. Furthermore, the number of embryos that can be imaged concurrently is limited by the number of receiver channels. The objective of this study is to provide measured comparative data to guide choices for high-throughput mouse embryo MR microscopy and other similar applications.
(c) 2010 Wiley-Liss, Inc.
Similar articles
- Cardiac phenotyping in ex vivo murine embryos using microMRI.
Cleary JO, Price AN, Thomas DL, Scambler PJ, Kyriakopoulou V, McCue K, Schneider JE, Ordidge RJ, Lythgoe MF. Cleary JO, et al. NMR Biomed. 2009 Oct;22(8):857-66. doi: 10.1002/nbm.1400. NMR Biomed. 2009. PMID: 19598179 - Morphologic phenotyping with MR microscopy: the visible mouse.
Johnson GA, Cofer GP, Gewalt SL, Hedlund LW. Johnson GA, et al. Radiology. 2002 Mar;222(3):789-93. doi: 10.1148/radiol.2223010531. Radiology. 2002. PMID: 11867802 - Phenotyping the central nervous system of the embryonic mouse by magnetic resonance microscopy.
Martínez-Martínez MA, Pacheco-Torres J, Borrell V, Canals S. Martínez-Martínez MA, et al. Neuroimage. 2014 Aug 15;97:95-106. doi: 10.1016/j.neuroimage.2014.04.043. Epub 2014 Apr 22. Neuroimage. 2014. PMID: 24769183 - 3-dimensional imaging modalities for phenotyping genetically engineered mice.
Powell KA, Wilson D. Powell KA, et al. Vet Pathol. 2012 Jan;49(1):106-15. doi: 10.1177/0300985811429814. Epub 2011 Dec 6. Vet Pathol. 2012. PMID: 22146851 Free PMC article. Review. - Embryonic and neonatal phenotyping of genetically engineered mice.
Kulandavelu S, Qu D, Sunn N, Mu J, Rennie MY, Whiteley KJ, Walls JR, Bock NA, Sun JC, Covelli A, Sled JG, Adamson SL. Kulandavelu S, et al. ILAR J. 2006;47(2):103-17. doi: 10.1093/ilar.47.2.103. ILAR J. 2006. PMID: 16547367 Review.
Cited by
- A volume birdcage coil with an adjustable sliding tuner ring for neuroimaging in high field vertical magnets: ex and in vivo applications at 21.1T.
Qian C, Masad IS, Rosenberg JT, Elumalai M, Brey WW, Grant SC, Gor'kov PL. Qian C, et al. J Magn Reson. 2012 Aug;221:110-6. doi: 10.1016/j.jmr.2012.05.016. Epub 2012 May 30. J Magn Reson. 2012. PMID: 22750638 Free PMC article. - Deciphering the Mechanisms of Developmental Disorders (DMDD): a new programme for phenotyping embryonic lethal mice.
Mohun T, Adams DJ, Baldock R, Bhattacharya S, Copp AJ, Hemberger M, Houart C, Hurles ME, Robertson E, Smith JC, Weaver T, Weninger W. Mohun T, et al. Dis Model Mech. 2013 May;6(3):562-6. doi: 10.1242/dmm.011957. Epub 2013 Mar 18. Dis Model Mech. 2013. PMID: 23519034 Free PMC article. - Automated pipeline for anatomical phenotyping of mouse embryos using micro-CT.
Wong MD, Maezawa Y, Lerch JP, Henkelman RM. Wong MD, et al. Development. 2014 Jun;141(12):2533-41. doi: 10.1242/dev.107722. Epub 2014 May 21. Development. 2014. PMID: 24850858 Free PMC article. - Diffusion tensor imaging using multiple coils for mouse brain connectomics.