Comparative effectiveness and safety of methods of insulin delivery and glucose monitoring for diabetes mellitus: a systematic review and meta-analysis - PubMed (original) (raw)
Meta-Analysis
Comparative effectiveness and safety of methods of insulin delivery and glucose monitoring for diabetes mellitus: a systematic review and meta-analysis
Hsin-Chieh Yeh et al. Ann Intern Med. 2012.
Free article
Abstract
Background: Patients with diabetes mellitus need information about the effectiveness of innovations in insulin delivery and glucose monitoring.
Purpose: To review how intensive insulin therapy (multiple daily injections [MDI] vs. rapid-acting analogue-based continuous subcutaneous insulin infusion [CSII]) or method of monitoring (self-monitoring of blood glucose [SMBG] vs. real-time continuous glucose monitoring [rt-CGM]) affects outcomes in types 1 and 2 diabetes mellitus.
Data sources: MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials through February 2012 without language restrictions.
Study selection: 33 randomized, controlled trials in children or adults that compared CSII with MDI (n=19), rt-CGM with SMBG (n=10), or sensor-augmented insulin pump use with MDI and SMBG (n=4).
Data extraction: 2 reviewers independently evaluated studies for eligibility and quality and serially abstracted data.
Data synthesis: In randomized, controlled trials, MDI and CSII showed similar effects on hemoglobin A1c (HbA1c) levels and severe hypoglycemia in children or adults with type 1 diabetes mellitus and adults with type 2 diabetes mellitus. In adults with type 1 diabetes mellitus, HbA1c levels decreased more with CSII than with MDI, but 1 study heavily influenced these results. Compared with SMBG, rt-CGM achieved a lower HbA1c level (between-group difference of change, 0.26% [95% CI, 0.33% to 0.19%]) without any difference in severe hypoglycemia. Sensor-augmented insulin pump use decreased HbA1c levels more than MDI and SMBG did in persons with type 1 diabetes mellitus (between-group difference of change, 0.68% [CI, 0.81% to 0.54%]). Little evidence was available on other outcomes.
Limitation: Many studies were small, of short duration, and limited to white persons with type 1 diabetes mellitus.
Conclusion: Continuous subcutaneous insulin infusion and MDI have similar effects on glycemic control and hypoglycemia, except CSII has a favorable effect on glycemic control in adults with type 1 diabetes mellitus. For glycemic control, rt-CGM is superior to SMBG and sensor-augmented insulin pumps are superior to MDI and SMBG without increasing the risk for hypoglycemia.
Primary funding source: Agency for Healthcare Research and Quality.
Comment in
- ACP Journal Club. Review: continuous glucose monitoring reduces HbA1c more than self-monitoring in type 1 diabetes.
Burden AC. Burden AC. Ann Intern Med. 2013 Mar 19;158(6):JC9. doi: 10.7326/0003-4819-158-6-201303190-02009. Ann Intern Med. 2013. PMID: 23552900 No abstract available.
Similar articles
- Methods for insulin delivery and glucose monitoring in diabetes: summary of a comparative effectiveness review.
Golden SH, Sapir T. Golden SH, et al. J Manag Care Pharm. 2012 Aug;18(6 Suppl):S1-17. doi: 10.18553/jmcp.2012.18.s6-a.1. J Manag Care Pharm. 2012. PMID: 22984955 Free PMC article. - Continuous glucose monitoring systems for type 1 diabetes mellitus.
Langendam M, Luijf YM, Hooft L, Devries JH, Mudde AH, Scholten RJ. Langendam M, et al. Cochrane Database Syst Rev. 2012 Jan 18;1(1):CD008101. doi: 10.1002/14651858.CD008101.pub2. Cochrane Database Syst Rev. 2012. PMID: 22258980 Free PMC article. - Integrated sensor-augmented pump therapy systems [the MiniMed® Paradigm™ Veo system and the Vibe™ and G4® PLATINUM CGM (continuous glucose monitoring) system] for managing blood glucose levels in type 1 diabetes: a systematic review and economic evaluation.
Riemsma R, Corro Ramos I, Birnie R, Büyükkaramikli N, Armstrong N, Ryder S, Duffy S, Worthy G, Al M, Severens J, Kleijnen J. Riemsma R, et al. Health Technol Assess. 2016 Feb;20(17):v-xxxi, 1-251. doi: 10.3310/hta20170. Health Technol Assess. 2016. PMID: 26933827 Free PMC article. - Clinical and cost-effectiveness of continuous subcutaneous insulin infusion for diabetes.
Colquitt JL, Green C, Sidhu MK, Hartwell D, Waugh N. Colquitt JL, et al. Health Technol Assess. 2004 Oct;8(43):iii, 1-171. doi: 10.3310/hta8430. Health Technol Assess. 2004. PMID: 15488165 - Continuous subcutaneous insulin infusion versus multiple daily injections of insulin for pregnant women with diabetes.
Farrar D, Tuffnell DJ, West J, West HM. Farrar D, et al. Cochrane Database Syst Rev. 2016 Jun 7;2016(6):CD005542. doi: 10.1002/14651858.CD005542.pub3. Cochrane Database Syst Rev. 2016. PMID: 27272351 Free PMC article.
Cited by
- HypoDE: Research Design and Methods of a Randomized Controlled Study Evaluating the Impact of Real-Time CGM Usage on the Frequency of CGM Glucose Values <55 mg/dl in Patients With Type 1 Diabetes and Problematic Hypoglycemia Treated With Multiple Daily Injections.
Heinemann L, Deiss D, Hermanns N, Graham C, Kaltheuner M, Liebl A, Price D. Heinemann L, et al. J Diabetes Sci Technol. 2015 May;9(3):651-62. doi: 10.1177/1932296815575999. Epub 2015 Mar 9. J Diabetes Sci Technol. 2015. PMID: 25759183 Free PMC article. Clinical Trial. - Continuous Subcutaneous Insulin Infusion Characteristics in Type 1 Diabetes Children and Adolescents in Qatar.
Petrovski G, Al Khalaf F, Hussain K, Campbell J, El Awwa A. Petrovski G, et al. Diabetes Ther. 2018 Oct;9(5):2091-2098. doi: 10.1007/s13300-018-0510-5. Epub 2018 Sep 15. Diabetes Ther. 2018. PMID: 30220038 Free PMC article. - Association Between Poor Sleep Quality and Glycemic Control in Adult Patients with Diabetes Referred to Endocrinology Clinic of Guilan: A Cross-sectional Study.
Mehrdad M, Azarian M, Sharafkhaneh A, Alavi A, Zare R, Hassanzadeh Rad A, Dalili S. Mehrdad M, et al. Int J Endocrinol Metab. 2021 Dec 5;20(1):e118077. doi: 10.5812/ijem.118077. eCollection 2022 Jan. Int J Endocrinol Metab. 2021. PMID: 35432555 Free PMC article. - The evidence base for diabetes technology: appropriate and inappropriate meta-analysis.
Pickup JC. Pickup JC. J Diabetes Sci Technol. 2013 Nov 1;7(6):1567-74. doi: 10.1177/193229681300700617. J Diabetes Sci Technol. 2013. PMID: 24351183 Free PMC article. Review. - Continuous Glucose Monitoring with Multiple Daily Insulin Treatment: Outcome Studies.
McGill JB, Ahmann A. McGill JB, et al. Diabetes Technol Ther. 2017 Jun;19(S3):S3-S12. doi: 10.1089/dia.2017.0090. Diabetes Technol Ther. 2017. PMID: 28585875 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical