Interactions at the blood/material interface
H P Greisler. Ann Vasc Surg. 1990 Jan.
Abstract
The complex interactions occurring at the blood/material interface of implanted blood-contacting biomaterials largely determine the clinical efficacy of small diameter vascular grafts. Physical characteristics of the material such as chemical composition, electrical charge, surface texture, elastic modulus, and porosity all affect many responses at the interfaces with blood, surrounding tissues, and adjacent artery. Some responses begin instantaneously (deposition of plasma proteins and platelets) while other reactions are somewhat delayed (deposition of leukocytes and monocytes, and migration of endothelial cells and smooth muscle cells). Each of these elements may become activated and release bioactive substances which further affect the behavior of the other entities in this complex and dynamic microenvironment. It is precisely these tissue reactions that regulate thrombogenicity and the development of pseudointimal hyperplasia.
Similar articles
- Luminal surface microgeometry affects platelet adhesion in small-diameter synthetic grafts.
Losi P, Lombardi S, Briganti E, Soldani G. Losi P, et al. Biomaterials. 2004 Aug;25(18):4447-55. doi: 10.1016/j.biomaterials.2003.11.025. Biomaterials. 2004. PMID: 15046935 - Matching the diameter of ePTFE bypass prosthesis with a native artery improves neoendothelialization.
Cikirikcioglu M, Pektok E, Cikirikcioglu YB, Osorio-da Cruz S, Tille JC, Kalangos A, Walpoth BH. Cikirikcioglu M, et al. Eur Surg Res. 2008;40(4):333-40. doi: 10.1159/000118029. Epub 2008 Feb 26. Eur Surg Res. 2008. PMID: 18303269 - Endothelialization of small-diameter vascular prostheses.
van der Zijpp YJ, Poot AA, Feijen J. van der Zijpp YJ, et al. Arch Physiol Biochem. 2003 Dec;111(5):415-27. doi: 10.3109/13813450312331342274. Arch Physiol Biochem. 2003. PMID: 16026029 - Haemocompatibility testing of biomaterials using human platelets.
Jung F, Braune S, Lendlein A. Jung F, et al. Clin Hemorheol Microcirc. 2013;53(1-2):97-115. doi: 10.3233/CH-2012-1579. Clin Hemorheol Microcirc. 2013. PMID: 22954639 Review. - Problems in the construction of a small diameter graft.
Callow AD. Callow AD. Int Angiol. 1988 Jul-Sep;7(3):246-53. Int Angiol. 1988. PMID: 3058835 Review.
Cited by
- Biomaterials for vascular tissue engineering.
Ravi S, Chaikof EL. Ravi S, et al. Regen Med. 2010 Jan;5(1):107-20. doi: 10.2217/rme.09.77. Regen Med. 2010. PMID: 20017698 Free PMC article. Review. - A hybrid biomimetic nanomatrix composed of electrospun polycaprolactone and bioactive peptide amphiphiles for cardiovascular implants.
Andukuri A, Kushwaha M, Tambralli A, Anderson JM, Dean DR, Berry JL, Sohn YD, Yoon YS, Brott BC, Jun HW. Andukuri A, et al. Acta Biomater. 2011 Jan;7(1):225-33. doi: 10.1016/j.actbio.2010.08.013. Epub 2010 Aug 20. Acta Biomater. 2011. PMID: 20728588 Free PMC article. - Quantitative Proteomic Characterization of Foreign Body Response towards Silicone Breast Implants Identifies Chronological Disease-Relevant Biomarker Dynamics.
Schoberleitner I, Faserl K, Sarg B, Egle D, Brunner C, Wolfram D. Schoberleitner I, et al. Biomolecules. 2023 Feb 6;13(2):305. doi: 10.3390/biom13020305. Biomolecules. 2023. PMID: 36830674 Free PMC article. - Hemocompatibility of Super-Repellent surfaces: Current and Future.
Movafaghi S, Wang W, Bark DL Jr, Dasi LP, Popat KC, Kota AK. Movafaghi S, et al. Mater Horiz. 2019 Oct 1;6(8):1596-1610. doi: 10.1039/C9MH00051H. Epub 2019 May 15. Mater Horiz. 2019. PMID: 31903188 Free PMC article. - Surface modification of uniaxial cyclic strain cell culture platform with temperature-responsive polymer for cell sheet detachment.
Lee EL, Bendre HH, Kalmykov A, Wong JY. Lee EL, et al. J Mater Chem B. 2015 Oct 28;3(40):7899-7902. doi: 10.1039/c5tb01171j. Epub 2015 Aug 19. J Mater Chem B. 2015. PMID: 26660468 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical