Prospective and retrospective high order eddy current mitigation for diffusion weighted echo planar imaging - PubMed (original) (raw)
. 2013 Nov;70(5):1293-305.
doi: 10.1002/mrm.24589. Epub 2013 Jan 16.
Affiliations
- PMID: 23325564
- DOI: 10.1002/mrm.24589
Free article
Prospective and retrospective high order eddy current mitigation for diffusion weighted echo planar imaging
Dan Xu et al. Magn Reson Med. 2013 Nov.
Free article
Abstract
Purpose: The proposed method is aimed at reducing eddy current (EC) induced distortion in diffusion weighted echo planar imaging, without the need to perform further image coregistration between diffusion weighted and T2 images. These ECs typically have significant high order spatial components that cannot be compensated by preemphasis.
Theory and methods: High order ECs are first calibrated at the system level in a protocol independent fashion. The resulting amplitudes and time constants of high order ECs can then be used to calculate imaging protocol specific corrections. A combined prospective and retrospective approach is proposed to apply correction during data acquisition and image reconstruction.
Results: Various phantom, brain, body, and whole body diffusion weighted images with and without the proposed method are acquired. Significantly reduced image distortion and misregistration are consistently seen in images with the proposed method compared with images without.
Conclusion: The proposed method is a powerful (e.g., effective at 48 cm field of view and 30 cm slice coverage) and flexible (e.g., compatible with other image enhancements and arbitrary scan plane) technique to correct high order ECs induced distortion and misregistration for various diffusion weighted echo planar imaging applications, without the need for further image post processing, protocol dependent prescan, or sacrifice in signal-to-noise ratio.
Keywords: EPI; artifacts; diffusion MRI; distortion; eddy currents.
Copyright © 2013 Wiley Periodicals, Inc.
Similar articles
- Geometric distortion correction of high-resolution 3 T diffusion tensor brain images.
Ardekani S, Sinha U. Ardekani S, et al. Magn Reson Med. 2005 Nov;54(5):1163-71. doi: 10.1002/mrm.20651. Magn Reson Med. 2005. PMID: 16187289 Clinical Trial. - Accelerated point spread function mapping using signal modeling for accurate echo-planar imaging geometric distortion correction.
Dragonu I, Lange T, Baxan N, Snyder J, Hennig J, Zaitsev M. Dragonu I, et al. Magn Reson Med. 2013 Jun;69(6):1650-6. doi: 10.1002/mrm.24396. Epub 2012 Jul 17. Magn Reson Med. 2013. PMID: 22807105 - Diffusion-weighted 3D multislab echo planar imaging for high signal-to-noise ratio efficiency and isotropic image resolution.
Engström M, Skare S. Engström M, et al. Magn Reson Med. 2013 Dec;70(6):1507-14. doi: 10.1002/mrm.24594. Epub 2013 Jan 28. Magn Reson Med. 2013. PMID: 23359357 - Practical aspects of assessing tumors using clinical diffusion-weighted imaging in the body.
Koh DM, Takahara T, Imai Y, Collins DJ. Koh DM, et al. Magn Reson Med Sci. 2007;6(4):211-24. doi: 10.2463/mrms.6.211. Magn Reson Med Sci. 2007. PMID: 18239358 Review. - [Selected clinically established and scientific techniques of diffusion-weighted MRI. In the context of imaging in oncology].
Freitag MT, Bickelhaupt S, Ziener C, Meier-Hein K, Radtke JP, Mosebach J, Kuder TA, Schlemmer HP, Laun FB. Freitag MT, et al. Radiologe. 2016 Feb;56(2):137-47. doi: 10.1007/s00117-015-0066-6. Radiologe. 2016. PMID: 26801187 Review. German.
Cited by
- Pre-excitation gradients for eddy current nulled convex optimized diffusion encoding (Pre-ENCODE).
Middione MJ, Loecher M, Cao X, Setsompop K, Ennis DB. Middione MJ, et al. Magn Reson Med. 2024 Aug;92(2):573-585. doi: 10.1002/mrm.30068. Epub 2024 Mar 19. Magn Reson Med. 2024. PMID: 38501914 - Mapping the human connectome using diffusion MRI at 300 mT/m gradient strength: Methodological advances and scientific impact.
Fan Q, Eichner C, Afzali M, Mueller L, Tax CMW, Davids M, Mahmutovic M, Keil B, Bilgic B, Setsompop K, Lee HH, Tian Q, Maffei C, Ramos-Llordén G, Nummenmaa A, Witzel T, Yendiki A, Song YQ, Huang CC, Lin CP, Weiskopf N, Anwander A, Jones DK, Rosen BR, Wald LL, Huang SY. Fan Q, et al. Neuroimage. 2022 Jul 1;254:118958. doi: 10.1016/j.neuroimage.2022.118958. Epub 2022 Feb 23. Neuroimage. 2022. PMID: 35217204 Free PMC article. Review. - Quantitative diffusion MRI of the abdomen and pelvis.
Hernando D, Zhang Y, Pirasteh A. Hernando D, et al. Med Phys. 2022 Apr;49(4):2774-2793. doi: 10.1002/mp.15246. Epub 2021 Oct 8. Med Phys. 2022. PMID: 34554579 Free PMC article. - The effect of spiral trajectory correction on pseudo-continuous arterial spin labeling with high-performance gradients on a compact 3T scanner.
Kang D, Yarach U, In MH, Gray EM, Trzasko JD, Jo HJ, Shu Y, Huston J 3rd, Bernstein MA. Kang D, et al. Magn Reson Med. 2020 Jul;84(1):192-205. doi: 10.1002/mrm.28110. Epub 2019 Dec 4. Magn Reson Med. 2020. PMID: 31799747 Free PMC article. - Optimized Diffusion-Weighting Gradient Waveform Design (ODGD) formulation for motion compensation and concomitant gradient nulling.
Peña-Nogales Ó, Zhang Y, Wang X, de Luis-Garcia R, Aja-Fernández S, Holmes JH, Hernando D. Peña-Nogales Ó, et al. Magn Reson Med. 2019 Feb;81(2):989-1003. doi: 10.1002/mrm.27462. Epub 2018 Nov 5. Magn Reson Med. 2019. PMID: 30394568 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources