Variability and reproducibility of flow-mediated dilatation in a multicentre clinical trial - PubMed (original) (raw)
Randomized Controlled Trial
. 2013 Dec;34(45):3501-7.
doi: 10.1093/eurheartj/eht223. Epub 2013 Jul 2.
Affiliations
- PMID: 23821401
- DOI: 10.1093/eurheartj/eht223
Randomized Controlled Trial
Variability and reproducibility of flow-mediated dilatation in a multicentre clinical trial
Marietta Charakida et al. Eur Heart J. 2013 Dec.
Abstract
Aims: The aim of this study was to assess the reproducibility of flow-mediated dilatation (FMD) in a multicentre setting.
Methods and results: This study was performed as part of the dal-VESSEL trial in which FMD was measured in 19 vascular imaging centres in six European countries. A subgroup of patients who were allocated in the placebo group and scanned twice at each trial time point (substudy) was analysed. Intra-sonographer variability was calculated from FMD measurements 48 h apart. Centre variability and short-, medium-, and long-term reproducibility of FMD were calculated at 48 h and at 3 and 9 months intervals, respectively. Intra- and inter-reader variability was assessed by re-analysing the FMD images by three certified readers at two time intervals, 7 days apart. Sixty-seven patients were included. Variability between centres was comparable at 48 h and 3 months interval but almost doubled at 9 months. The mean absolute difference in %FMD was 1.04, 0.99, and 1.45% at the three time intervals, respectively. Curves were generated to indicate the number of patients required for adequate power in crossover and parallel study designs.
Conclusion: This study demonstrates for the first time that in a multicentre setting reproducible FMD measurements can be achieved for short- and medium-term evaluation, which are comparable with those reported from specialized laboratories. These findings justify the use of FMD as an outcome measure for short- and medium-term assessment of pharmacological interventions.
Keywords: Coronary artery disease; FMD; Power curve; Reproducibility.
Similar articles
- Interobserver and intraobserver variability of flow-mediated vasodilatation of the brachial artery.
Simova I, Nossikoff A, Denchev S. Simova I, et al. Echocardiography. 2008 Jan;25(1):77-83. doi: 10.1111/j.1540-8175.2007.00552.x. Echocardiography. 2008. PMID: 18186783 - Intrasubject variability of radial artery flow-mediated dilatation in healthy subjects and implications for use in prospective clinical trials.
Brook R, Grau M, Kehrer C, Dellegrottaglie S, Khan B, Rajagopalan S. Brook R, et al. Am J Cardiol. 2005 Nov 1;96(9):1345-8. doi: 10.1016/j.amjcard.2005.06.086. Epub 2005 Sep 16. Am J Cardiol. 2005. PMID: 16253612 - New methodological approach to improve reproducibility of brachial artery flow-mediated dilatation.
Kanahara M, Harada H, Katoh A, Ikeda H. Kanahara M, et al. Echocardiography. 2014 Feb;31(2):197-202. doi: 10.1111/echo.12307. Epub 2013 Jul 30. Echocardiography. 2014. PMID: 23909753 - Assessment of flow-mediated vasodilatation (FMD) of the brachial artery: effects of technical aspects of the FMD measurement on the FMD response.
Bots ML, Westerink J, Rabelink TJ, de Koning EJ. Bots ML, et al. Eur Heart J. 2005 Feb;26(4):363-8. doi: 10.1093/eurheartj/ehi017. Epub 2004 Dec 1. Eur Heart J. 2005. PMID: 15618057 Review. - [Brachial arterial flow mediated dilation: utility in clinical and experimental practice].
Santos-García D, Rodríguez-Yáñez M, Arias-Rivas S, Blanco M. Santos-García D, et al. Rev Neurol. 2011 Sep 16;53(6):351-60. Rev Neurol. 2011. PMID: 21894606 Review. Spanish.
Cited by
- Variability of flow-mediated dilation across lower and upper limb conduit arteries.
Daniele A, Lucas SJE, Rendeiro C. Daniele A, et al. Eur J Appl Physiol. 2024 Nov;124(11):3265-3278. doi: 10.1007/s00421-024-05517-z. Epub 2024 Jun 15. Eur J Appl Physiol. 2024. PMID: 38878074 Free PMC article. - Effect of an eight-week high-intensity interval training programme on circulating sphingolipid levels in middle-aged adults at elevated cardiometabolic risk (SphingoFIT)-Protocol for a randomised controlled exercise trial.
Carrard J, Hofer M, Prechtl L, Fleischlin E, Huber M, Gallart-Ayala H, Teav T, Infanger D, Höchsmann C, Koehler K, Hinrichs T, Hanssen H, Ivanisevic J, Schmidt-Trucksäss A. Carrard J, et al. PLoS One. 2024 May 8;19(5):e0302477. doi: 10.1371/journal.pone.0302477. eCollection 2024. PLoS One. 2024. PMID: 38717997 Free PMC article. Clinical Trial. - The effect of cardiorespiratory fitness and habitual physical activity on cardiovascular responses to 2 h of uninterrupted sitting.
Paterson C, Stone K, Turner L, Moinuddin A, Stoner L, Fryer S. Paterson C, et al. J Appl Physiol (1985). 2024 May 1;136(5):1087-1096. doi: 10.1152/japplphysiol.00361.2023. Epub 2024 Mar 14. J Appl Physiol (1985). 2024. PMID: 38482575 - Intra and inter-rater repeatability of brachial artery ultrasound estimates of flow-mediated slowing and flow-mediated dilation.
Marôco JL, Silvestre T, Arrais I, Pinto M, Santa-Clara H, Fernhall B, Melo X. Marôco JL, et al. PLoS One. 2023 Jun 28;18(6):e0287759. doi: 10.1371/journal.pone.0287759. eCollection 2023. PLoS One. 2023. PMID: 37379344 Free PMC article. - Endothelial Function Assessment by Flow-Mediated Dilation Method: A Valuable Tool in the Evaluation of the Cardiovascular System.
Mućka S, Miodońska M, Jakubiak GK, Starzak M, Cieślar G, Stanek A. Mućka S, et al. Int J Environ Res Public Health. 2022 Sep 7;19(18):11242. doi: 10.3390/ijerph191811242. Int J Environ Res Public Health. 2022. PMID: 36141513 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources