Relationship between intracortical electrode design and chronic recording function
Lohitash Karumbaiah et al. Biomaterials. 2013 Nov.
Abstract
Intracortical electrodes record neural signals directly from local populations of neurons in the brain, and conduct them to external electronics that control prosthetics. However, the relationship between electrode design, defined by shape, size and tethering; and long-term (chronic) stability of the neuron-electrode interface is poorly understood. Here, we studied the effects of various commercially available intracortical electrode designs that vary in shape (cylindrical, planar), size (15 μm, 50 μm and 75 μm), and tethering [electrode connections to connector with (tethered) and without tethering cable (untethered)] using histological, transcriptomic, and electrophysiological analyses over acute (3 day) and chronic (12 week) timepoints. Quantitative analysis of histological sections indicated that Michigan 50 μm (M50) and Michigan tethered (MT) electrodes induced significantly (p < 0.01) higher glial scarring, and lesser survival of neurons in regions of blood-brain barrier (BBB) breach when compared to microwire (MW) and Michigan 15 μm (M15) electrodes acutely and chronically. Gene expression analysis of the neurotoxic cytokines interleukin (Il)1 (Il1α, Il1β), Il6, Il17 (Il17a, Il17b, Il17f), and tumor necrosis factor alpha (Tnf) indicated that MW electrodes induced significantly (p < 0.05) reduced expression of these transcripts when compared to M15, M50 and FMAA electrodes chronically. Finally, electrophysiological assessment of electrode function indicated that MW electrodes performed significantly (p < 0.05) better than all other electrodes over a period of 12 weeks. These studies reveal that intracortical electrodes with smaller size, cylindrical shape, and without tethering cables produce significantly diminished inflammatory responses when compared to large, planar and tethered electrodes. These studies provide a platform for the rational design and assessment of chronically functional intracortical electrode implants in the future.
Keywords: Brain–computer interface; Cytokines; Foreign body response; Inflammation; Intracortical electrodes; Neuroprosthetics.
© 2013 Elsevier Ltd. All rights reserved.
Similar articles
- The impact of chronic blood-brain barrier breach on intracortical electrode function.
Saxena T, Karumbaiah L, Gaupp EA, Patkar R, Patil K, Betancur M, Stanley GB, Bellamkonda RV. Saxena T, et al. Biomaterials. 2013 Jul;34(20):4703-13. doi: 10.1016/j.biomaterials.2013.03.007. Epub 2013 Apr 2. Biomaterials. 2013. PMID: 23562053 - Ultrasoft microwire neural electrodes improve chronic tissue integration.
Du ZJ, Kolarcik CL, Kozai TDY, Luebben SD, Sapp SA, Zheng XS, Nabity JA, Cui XT. Du ZJ, et al. Acta Biomater. 2017 Apr 15;53:46-58. doi: 10.1016/j.actbio.2017.02.010. Epub 2017 Feb 6. Acta Biomater. 2017. PMID: 28185910 Free PMC article. - The impact of modulating the blood-brain barrier on the electrophysiological and histological outcomes of intracortical electrodes.
Falcone JD, Sohal HS, Kyriakides TR, Bellamkonda RV. Falcone JD, et al. J Neural Eng. 2019 Aug;16(4):046005. doi: 10.1088/1741-2552/ab1ef9. Epub 2019 May 2. J Neural Eng. 2019. PMID: 31048574 - Physiological challenges for intracortical electrodes.
Groothuis J, Ramsey NF, Ramakers GM, van der Plasse G. Groothuis J, et al. Brain Stimul. 2014 Jan-Feb;7(1):1-6. doi: 10.1016/j.brs.2013.07.001. Epub 2013 Aug 2. Brain Stimul. 2014. PMID: 23941984 Review. - Biological, mechanical, and technological considerations affecting the longevity of intracortical electrode recordings.
Harris JP, Tyler DJ. Harris JP, et al. Crit Rev Biomed Eng. 2013;41(6):435-56. Crit Rev Biomed Eng. 2013. PMID: 24940658 Review.
Cited by
- Enhancing biocompatibility of the brain-machine interface: A review.
Villa J, Cury J, Kessler L, Tan X, Richter CP. Villa J, et al. Bioact Mater. 2024 Sep 11;42:531-549. doi: 10.1016/j.bioactmat.2024.08.034. eCollection 2024 Dec. Bioact Mater. 2024. PMID: 39308547 Free PMC article. Review. - Design, Fabrication, and Implantation of Invasive Microelectrode Arrays as in vivo Brain Machine Interfaces: A Comprehensive Review.
Yi D, Yao Y, Wang Y, Chen L. Yi D, et al. J Manuf Process. 2024 Sep 30;126:185-207. doi: 10.1016/j.jmapro.2024.07.100. Epub 2024 Jul 31. J Manuf Process. 2024. PMID: 39185373 - Glial scarring around intra-cortical MEA implants with flexible and free microwires inserted using biodegradable PLGA needles.
Darlot F, Villard P, Salam LA, Rousseau L, Piret G. Darlot F, et al. Front Bioeng Biotechnol. 2024 Jul 22;12:1408088. doi: 10.3389/fbioe.2024.1408088. eCollection 2024. Front Bioeng Biotechnol. 2024. PMID: 39104630 Free PMC article. - Harnessing the Stem Cell Niche in Regenerative Medicine: Innovative Avenue to Combat Neurodegenerative Diseases.
Velikic G, Maric DM, Maric DL, Supic G, Puletic M, Dulic O, Vojvodic D. Velikic G, et al. Int J Mol Sci. 2024 Jan 12;25(2):993. doi: 10.3390/ijms25020993. Int J Mol Sci. 2024. PMID: 38256066 Free PMC article. Review. - Exploring CVD Method for Synthesizing Carbon-Carbon Composites as Materials to Contact with Nerve Tissue.
Fraczek-Szczypta A, Kondracka N, Zambrzycki M, Gubernat M, Czaja P, Pawlyta M, Jelen P, Wielowski R, Jantas D. Fraczek-Szczypta A, et al. J Funct Biomater. 2023 Aug 28;14(9):443. doi: 10.3390/jfb14090443. J Funct Biomater. 2023. PMID: 37754857 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous