Abstract
Due to expanding clinical indications and an aging society there has been an increase in the use of implantable pacemakers. At the same time, due to increased diagnostic yield over other imaging modalities and the absence of ionizing radiation, there has been a surge in demand for magnetic resonance imaging (MRI) assessment, of both cardiac and noncardiac conditions. Patients with an implantable device have a 50-75% chance of having a clinical indication for MRI during the lifetime of their device. The presence of an implantable cardiac device has been seen as a relative contraindication to MRI assessment, limiting the prognostic and diagnostic utility of MRI in many patients with these devices. The introduction of MRI conditional pacemakers will enable more patients to undergo routine MRI assessment without risk of morbidity or device malfunction. This review gives a general overview of the principles and current evidence for the use of MRI conditional implantable cardiac devices. Furthermore, we appraise the differences between those pacemakers currently released to market.
Keywords: implantable cardiac device; implantable cardioverter defibrillator; magnetic resonance imaging (MRI); pacemaker.
© 2013 Wiley Periodicals, Inc.
Similar articles
- [Pacemaker or ICD and MRI: is MRI safety the new standard?].
Amara W. Amara W. Ann Cardiol Angeiol (Paris). 2011 Nov;60(5):279-81. doi: 10.1016/j.ancard.2011.08.005. Epub 2011 Aug 26. Ann Cardiol Angeiol (Paris). 2011. PMID: 21907320 Review. French. - Determining the risks of magnetic resonance imaging at 1.5 tesla for patients with pacemakers and implantable cardioverter defibrillators.
Cohen JD, Costa HS, Russo RJ. Cohen JD, et al. Am J Cardiol. 2012 Dec 1;110(11):1631-6. doi: 10.1016/j.amjcard.2012.07.030. Epub 2012 Aug 23. Am J Cardiol. 2012. PMID: 22921995 - Impact of expanding indications on the safety of pacemakers and defibrillators.
Maisel WH; American Cardiology College; American Heart Association; North American Society of Pacing and Electrophysiology (NASPE). Maisel WH, et al. Card Electrophysiol Rev. 2003 Jan;7(1):30-2. doi: 10.1023/a:1023678620678. Card Electrophysiol Rev. 2003. PMID: 12766513 Review. - Real world MRI experience with nonconditional and conditional cardiac rhythm devices after MagnaSafe.
Mason S, Osborn JS, Dhar R, Tonkin A, Ethington JD, Le V, Benuzillo J, Lappe DL, Knowlton KU, Bunch TJ, Anderson JL. Mason S, et al. J Cardiovasc Electrophysiol. 2017 Dec;28(12):1468-1474. doi: 10.1111/jce.13351. Epub 2017 Nov 1. J Cardiovasc Electrophysiol. 2017. PMID: 28960745 Clinical Trial.
Cited by
- Thermo-Acoustic Ultrasound for Detection of RF-Induced Device Lead Heating in MRI.
Dixit N, Stang PP, Pauly JM, Scott GC. Dixit N, et al. IEEE Trans Med Imaging. 2018 Feb;37(2):536-546. doi: 10.1109/TMI.2017.2764425. Epub 2017 Oct 18. IEEE Trans Med Imaging. 2018. PMID: 29053449 Free PMC article. - Diagnosing malignant distal bile duct obstruction using artificial intelligence based on clinical biomarkers.
Sugimoto Y, Kurita Y, Kuwahara T, Satou M, Meguro K, Hosono K, Kubota K, Hara K, Nakajima A. Sugimoto Y, et al. Sci Rep. 2023 Feb 24;13(1):3262. doi: 10.1038/s41598-023-28058-5. Sci Rep. 2023. PMID: 36828831 Free PMC article. - MRI and cardiac implantable electronic devices; current status and required safety conditions.
van der Graaf AW, Bhagirath P, Götte MJ. van der Graaf AW, et al. Neth Heart J. 2014 Jun;22(6):269-76. doi: 10.1007/s12471-014-0544-x. Neth Heart J. 2014. PMID: 24733688 Free PMC article. - Detection of Pacemaker and Identification of MRI-conditional Pacemaker Based on Deep-learning Convolutional Neural Networks to Improve Patient Safety.
Do Y, Ahn SH, Kim S, Kim JK, Choi BW, Kim H, Lee YH. Do Y, et al. J Med Syst. 2023 Jul 31;47(1):80. doi: 10.1007/s10916-023-01981-w. J Med Syst. 2023. PMID: 37522981 - Performance and Physician Experience of INGEVITY+ Active Fixation Leads: Prospective INGEVITY+ Lead Clinical Study in Korea.
Joung B, Bae MH, Oh IY, Park HS, Shim J, Cho MS, Lee JM, Choi EK, Lee YS. Joung B, et al. Cardiol Res Pract. 2024 Jan 11;2024:2172306. doi: 10.1155/2024/2172306. eCollection 2024. Cardiol Res Pract. 2024. PMID: 38239431 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical