Cryo-Electron Tomography and Subtomogram Averaging - PubMed (original) (raw)
Review
Cryo-Electron Tomography and Subtomogram Averaging
W Wan et al. Methods Enzymol. 2016.
Abstract
Cryo-electron tomography (cryo-ET) allows 3D volumes to be reconstructed from a set of 2D projection images of a tilted biological sample. It allows densities to be resolved in 3D that would otherwise overlap in 2D projection images. Cryo-ET can be applied to resolve structural features in complex native environments, such as within the cell. Analogous to single-particle reconstruction in cryo-electron microscopy, structures present in multiple copies within tomograms can be extracted, aligned, and averaged, thus increasing the signal-to-noise ratio and resolution. This reconstruction approach, termed subtomogram averaging, can be used to determine protein structures in situ. It can also be applied to facilitate more conventional 2D image analysis approaches. In this chapter, we provide an introduction to cryo-ET and subtomogram averaging. We describe the overall workflow, including tomographic data collection, preprocessing, tomogram reconstruction, subtomogram alignment and averaging, classification, and postprocessing. We consider theoretical issues and practical considerations for each step in the workflow, along with descriptions of recent methodological advances and remaining limitations.
Keywords: Cryo-electron microscopy; Cryo-electron tomography; Image processing; In situ structural biology; Subtomogram averaging.
© 2016 Elsevier Inc. All rights reserved.
Similar articles
- Subtomogram averaging from cryo-electron tomograms.
Leigh KE, Navarro PP, Scaramuzza S, Chen W, Zhang Y, Castaño-Díez D, Kudryashev M. Leigh KE, et al. Methods Cell Biol. 2019;152:217-259. doi: 10.1016/bs.mcb.2019.04.003. Epub 2019 May 15. Methods Cell Biol. 2019. PMID: 31326022 Review. - Efficient 3D-CTF correction for cryo-electron tomography using NovaCTF improves subtomogram averaging resolution to 3.4Å.
Turoňová B, Schur FKM, Wan W, Briggs JAG. Turoňová B, et al. J Struct Biol. 2017 Sep;199(3):187-195. doi: 10.1016/j.jsb.2017.07.007. Epub 2017 Jul 22. J Struct Biol. 2017. PMID: 28743638 Free PMC article. - Current data processing strategies for cryo-electron tomography and subtomogram averaging.
Pyle E, Zanetti G. Pyle E, et al. Biochem J. 2021 May 28;478(10):1827-1845. doi: 10.1042/BCJ20200715. Biochem J. 2021. PMID: 34003255 Free PMC article. Review. - Dynamo Catalogue: Geometrical tools and data management for particle picking in subtomogram averaging of cryo-electron tomograms.
Castaño-Díez D, Kudryashev M, Stahlberg H. Castaño-Díez D, et al. J Struct Biol. 2017 Feb;197(2):135-144. doi: 10.1016/j.jsb.2016.06.005. Epub 2016 Jun 8. J Struct Biol. 2017. PMID: 27288866 - Structural biology in situ--the potential of subtomogram averaging.
Briggs JA. Briggs JA. Curr Opin Struct Biol. 2013 Apr;23(2):261-7. doi: 10.1016/j.sbi.2013.02.003. Epub 2013 Mar 4. Curr Opin Struct Biol. 2013. PMID: 23466038 Review.
Cited by
- Structure and dynamics of photoreceptor sensory cilia.
Wensel TG, Potter VL, Moye A, Zhang Z, Robichaux MA. Wensel TG, et al. Pflugers Arch. 2021 Sep;473(9):1517-1537. doi: 10.1007/s00424-021-02564-9. Epub 2021 May 28. Pflugers Arch. 2021. PMID: 34050409 Free PMC article. Review. - In vitro reconstitution reveals membrane clustering and RNA recruitment by the enteroviral AAA+ ATPase 2C.
Shankar K, Sorin MN, Sharma H, Skoglund O, Dahmane S, Ter Beek J, Tesfalidet S, Nenzén L, Carlson LA. Shankar K, et al. PLoS Pathog. 2024 Aug 5;20(8):e1012388. doi: 10.1371/journal.ppat.1012388. eCollection 2024 Aug. PLoS Pathog. 2024. PMID: 39102425 Free PMC article. - Advances in cryo-electron tomography and subtomogram averaging and classification.
Zhang P. Zhang P. Curr Opin Struct Biol. 2019 Oct;58:249-258. doi: 10.1016/j.sbi.2019.05.021. Epub 2019 Jul 5. Curr Opin Struct Biol. 2019. PMID: 31280905 Free PMC article. Review. - Coming of Age: Cryo-Electron Tomography as a Versatile Tool to Generate High-Resolution Structures at Cellular/Biological Interfaces.
Wang Z, Zhang Q, Mim C. Wang Z, et al. Int J Mol Sci. 2021 Jun 8;22(12):6177. doi: 10.3390/ijms22126177. Int J Mol Sci. 2021. PMID: 34201105 Free PMC article. Review. - The Dynamo package for tomography and subtomogram averaging: components for MATLAB, GPU computing and EC2 Amazon Web Services.
Castaño-Díez D. Castaño-Díez D. Acta Crystallogr D Struct Biol. 2017 Jun 1;73(Pt 6):478-487. doi: 10.1107/S2059798317003369. Epub 2017 Apr 20. Acta Crystallogr D Struct Biol. 2017. PMID: 28580909 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources