Comparison of Common Retinal Vessel Caliber Measurement Software and a Conversion Algorithm - PubMed (original) (raw)

Comparison of Common Retinal Vessel Caliber Measurement Software and a Conversion Algorithm

WanFen Yip et al. Transl Vis Sci Technol. 2016.

Abstract

Purpose: To compare three commonly used retinal vessel caliber measurement software systems, and propose an algorithm for conversion between measurement systems.

Methods: We used 120 retinal photographs to evaluate the agreement between three commonly used software (Retinal Analysis [RA], Integrative Vessel Analysis [IVAN], and Singapore I Vessel Assessment [SIVA]). Bland-Altman plots were used to evaluate agreement of retinal arteriolar (central retinal artery equivalent, CRAE) and venular (central retinal vein equivalent, CRVE) calibers. Pearson's correlation was used to assess the associations between systemic factors and retinal vessel calibers, and Z-test was used to compare the strength of the correlation coefficients across the three software systems. An algorithm was created to convert measurements, with paired _t_-test performed to evaluate the differences between SIVA-measured retinal calibers and SIVA-approximates converted from RA- and IVAN-measurements using the algorithm.

Results: Differences between SIVA- and RA-measured calibers (CRAE: mean difference [MD] = -21.8 μm, 95% limits of agreement [LOA], -47.3 to 3.7 μm; CRVE: MD = -7.7 μm, 95% LOA, -28.0 to 12.6 μm), SIVA- and IVAN-measured calibers (CRAE: MD = -6.7 μm, 95% LOA, -23.8 to 10.4 μm; CRVE: MD = -18.2 μm 95% LOA, -36.7 to 0.4 μm) were large. However, the strength of correlations between systemic factors with SIVA-measured retinal calibers was not significantly different to that measured using RA and IVAN (P ≥ 0.332). SIVA-approximates converted from RA and IVAN measurements using the proposed algorithm was not significantly different from SIVA-measured calibers (P ≥ 0.20).

Conclusion: Absolute measurements of retinal vessel calibers vary between three common software systems but associations with systemic factors were similar.

Translational relevance: The proposed algorithm allowed conversions of RA and IVAN measurements to SIVA-approximates. This conversion is important for future data pooling and establishment of normative values for retinal vascular caliber measurements.

Keywords: epidemiology; retinal vasculature; retinal vessels.

PubMed Disclaimer

Figures

Figure 1

Figure 1

(A) A screenshot of RA interface; (B) a screenshot of IVAN interface; (C) a screenshot of SIVA interface using the same fundus photo.

Figure 2

Figure 2

Bland Altman plot of agreement between SIVA and Retinal Analysis (n = 120): (A) retinal arteriolar caliber (CRAE); (B) retinal venular caliber (CRVE).

Figure 3

Figure 3

Bland Altman plot of agreement between SIVA and IVAN (n = 120): (A) retinal arteriolar caliber (CRAE); (B) retinal venular caliber (CRVE).

Figure 4

Figure 4

Bland Altman plot of agreement between RA and IVAN (n = 120): (A) retinal arteriolar caliber (CRAE); (B) retinal venular caliber (CRVE).

Figure 5

Figure 5

Correlation of MABP with retinal arteriolar caliber measured by (A) RA; (B) IVAN; (C) SIVA.

Figure 6

Figure 6

Correlation of total cholesterol with retinal venular caliber measured (A) RA; (B) IVAN; (C) SIVA.

References

    1. Ikram MK,, Ong YT,, Cheung CY,, Wong TY. Retinal vascular caliber measurements: clinical significance current knowledge and future perspectives. Ophthalmologica. 2013; 229: 125–136. - PubMed
    1. Cheung CY,, Ikram MK,, Sabanayagam C,, Wong TY. Retinal microvasculature as a model to study the manifestations of hypertension. Hypertension. 2012; 60: 1094–1103. - PubMed
    1. Walsh JB. Hypertensive retinopathy. Description, classification and prognosis. Ophthalmology. 1982; 89: 1127–1131. - PubMed
    1. Wong TY,, Klein R,, Klein BE,, Tielsch JM,, Hubbard L,, Nieto FJ. Retinal microvascular abnormalities and their relationship with hypertension, cardiovascular disease and mortality. Surv Ophthalmol. 2001; 46: 59–80. - PubMed
    1. Keith NM,, Wagener HP,, Barker NW. Some different types of essential hypertension: their course and prognosis. Am J Med Sci. 1974; 268: 336–345. - PubMed