Single Molecule Arrays for ultra-sensitive detection of rat cytokines in serum - PubMed (original) (raw)
Single Molecule Arrays for ultra-sensitive detection of rat cytokines in serum
Limor Cohen et al. J Immunol Methods. 2018 Jan.
Abstract
Rats are used as animal models for many human diseases. Cytokines can serve as biomarkers indicative of these diseases or disease states. Techniques for measuring cytokine expression levels often do not provide the sensitivity needed to measure these biomarkers in biological fluids because the concentrations of many cytokines are below the detection limits of conventional methods. In this paper, we present ultra-sensitive digital immunoassays using Single Molecule Arrays (Simoa) for seven rat cytokines: TNF-α, IL-10, IL-17F, GM-CSF, IFN-γ, IL-4, and IL-1α. These ultra-sensitive immunoassays have limits of detection (LODs) in the femtomolar range and provide the ability to measure rat cytokines in serum below the LODs of conventional immunoassays. We also measured these cytokines in healthy rat serum to obtain baseline levels. The ability to measure cytokines present at low concentrations in rat serum will facilitate future studies of disease using rats as animal models.
Keywords: Cytokine; Rat; Serum; Single Molecule Arrays.
Copyright © 2017 Elsevier B.V. All rights reserved.
Similar articles
- Single molecule array (Simoa) assay with optimal antibody pairs for cytokine detection in human serum samples.
Wu D, Milutinovic MD, Walt DR. Wu D, et al. Analyst. 2015 Sep 21;140(18):6277-82. doi: 10.1039/c5an01238d. Analyst. 2015. PMID: 26270328 - Optimization of multiplexed bead-based cytokine immunoassays for rat serum and brain tissue.
Hulse RE, Kunkler PE, Fedynyshyn JP, Kraig RP. Hulse RE, et al. J Neurosci Methods. 2004 Jun 15;136(1):87-98. doi: 10.1016/j.jneumeth.2003.12.023. J Neurosci Methods. 2004. PMID: 15126049 Free PMC article. - A fully-automated, six-plex single molecule immunoassay for measuring cytokines in blood.
Rivnak AJ, Rissin DM, Kan CW, Song L, Fishburn MW, Piech T, Campbell TG, DuPont DR, Gardel M, Sullivan S, Pink BA, Cabrera CG, Fournier DR, Duffy DC. Rivnak AJ, et al. J Immunol Methods. 2015 Sep;424:20-7. doi: 10.1016/j.jim.2015.04.017. Epub 2015 May 7. J Immunol Methods. 2015. PMID: 25960176 Free PMC article. - Advances in single molecule arrays (SIMOA) for ultra-sensitive detection of biomolecules.
Dong R, Yi N, Jiang D. Dong R, et al. Talanta. 2024 Apr 1;270:125529. doi: 10.1016/j.talanta.2023.125529. Epub 2023 Dec 10. Talanta. 2024. PMID: 38091745 Review. - The immunoassay of cytokines and growth factors in biological fluids.
Kopp W, Reynolds C, Ruscetti F. Kopp W, et al. Dev Biol Stand. 1999;97:29-37. Dev Biol Stand. 1999. PMID: 10463528 Review.
Cited by
- Is liquid biopsy mature enough for the diagnosis of Alzheimer's disease?
Gong X, Zhang H, Liu X, Liu Y, Liu J, Fapohunda FO, Lü P, Wang K, Tang M. Gong X, et al. Front Aging Neurosci. 2022 Aug 5;14:977999. doi: 10.3389/fnagi.2022.977999. eCollection 2022. Front Aging Neurosci. 2022. PMID: 35992602 Free PMC article. Review. - Simultaneous detection of small molecules, proteins and microRNAs using single molecule arrays.
Wang X, Walt DR. Wang X, et al. Chem Sci. 2020 Jul 8;11(30):7896-7903. doi: 10.1039/d0sc02552f. Chem Sci. 2020. PMID: 34094160 Free PMC article. - Ultrasensitive Detection of Enzymatic Activity Using Single Molecule Arrays.
Wang X, Ogata AF, Walt DR. Wang X, et al. J Am Chem Soc. 2020 Sep 2;142(35):15098-15106. doi: 10.1021/jacs.0c06599. Epub 2020 Aug 20. J Am Chem Soc. 2020. PMID: 32797755 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources