Abstract
Background: Anastomotic bile duct stricture (ABS) is one of the most common complications after liver transplantation. Current practice of endoscopic retrograde cholangiopancreatography (ERCP) with multiple plastic stent (MPS) insertion often requires multiple sessions before achieving stricture resolution. We aimed to compare the efficacy of fully covered self-expandable metallic stent (FCSEMS) with MPS method while simultaneously analyzing the relative healthcare cost between the two methods in the management of ABS.
Methods: Liver transplant patients with ABS who received ERCP with stent placement were identified by query of our endoscopic database. Comparative analyses between the group of patients treated with ERCP with MPS and the group treated with FCSEMS were performed. The costs to achieve stricture resolution, and the rates of stricture resolution, recurrence and complications were also compared.
Results: A total of 158 patients underwent ERCP with stent insertion for the management of ABS. Of those, 49 patient received FCSEMS for their ABS while 109 patients were treated with MPS only. Our cost analysis showed early utilization of FCSEMS can deliver up to 25% savings in the total procedure cost while providing comparable rates of stricture resolution. The rates of technical success, stricture recurrence and adverse outcomes, and stricture free durations were also comparable between the two groups.
Conclusion: While providing efficacy and safety rates comparable to ERCP-MPS, the incorporation of FCSEMS at early stage of ABS management could provide a substantial savings by reducing the number of ERCP session to achieve stricture resolution. Optimization of the timing and duration of FCSEMS indwelling time needs further validation.
Keywords: Biliary stricture; Endoscopic retrograde cholangiopancreatography; Liver transplant; Stent.
Comment in
- Concise Commentary: Penny Wise and Pound Foolish-Why SEMS Makes More Sense When Treating Post-anastomotic Biliary Strictures.
Khoury T, Kumar M, Mizrahi M. Khoury T, et al. Dig Dis Sci. 2020 Feb;65(2):609-610. doi: 10.1007/s10620-019-05810-4. Dig Dis Sci. 2020. PMID: 31555947 No abstract available.
Similar articles
- Clinical efficacy of anti-migration features in fully covered metallic stents for anastomotic biliary strictures after liver transplantation: comparison of conventional and anti-migration stents.
Bordaçahar B, Perdigao F, Leblanc S, Barret M, Duchmann JC, Guillaumot MA, Chaussade S, Scatton O, Prat F. Bordaçahar B, et al. Gastrointest Endosc. 2018 Oct;88(4):655-664. doi: 10.1016/j.gie.2018.06.035. Epub 2018 Jul 10. Gastrointest Endosc. 2018. PMID: 30003877 - Efficacy and Optimal Duration of Metallic Stent in the Management of Refractory Anastomotic Stricture After Liver Transplantation.
Jang S, Parsi MA, Lopez R, Bhatt A, Vargo JJ. Jang S, et al. Clin Gastroenterol Hepatol. 2017 Nov;15(11):1776-1781. doi: 10.1016/j.cgh.2017.06.015. Epub 2017 Jun 15. Clin Gastroenterol Hepatol. 2017. PMID: 28624651 - Metal versus plastic stents for anastomotic biliary strictures after liver transplantation: a randomized controlled trial.
Martins FP, De Paulo GA, Contini MLC, Ferrari AP. Martins FP, et al. Gastrointest Endosc. 2018 Jan;87(1):131.e1-131.e13. doi: 10.1016/j.gie.2017.04.013. Epub 2017 Apr 25. Gastrointest Endosc. 2018. PMID: 28455159 Clinical Trial. - Managing the post-liver transplantation anastomotic biliary stricture: multiple plastic versus metal stents: a systematic review.
Kao D, Zepeda-Gomez S, Tandon P, Bain VG. Kao D, et al. Gastrointest Endosc. 2013 May;77(5):679-91. doi: 10.1016/j.gie.2013.01.015. Epub 2013 Mar 6. Gastrointest Endosc. 2013. PMID: 23473000 Review. - Endoscopic treatment of anastomotic biliary stricture after adult deceased donor liver transplantation with multiple plastic stents versus self-expandable metal stents: a systematic review and meta-analysis.
Landi F, de'Angelis N, Sepulveda A, Martínez-Pérez A, Sobhani I, Laurent A, Soubrane O. Landi F, et al. Transpl Int. 2018 Feb;31(2):131-151. doi: 10.1111/tri.13089. Epub 2017 Nov 16. Transpl Int. 2018. PMID: 29090502 Review.
Cited by
- Antimigration versus conventional fully covered metal stents in the endoscopic treatment of anastomotic biliary strictures after deceased-donor liver transplantation.
Fuentes-Valenzuela E, de Benito Sanz M, García-Pajares F, Estradas J, Peñas-Herrero I, Durá-Gil M, Carbajo AY, de la Serna-Higuera C, Sanchez-Ocana R, Alonso-Martín C, Almohalla C, Sánchez-Antolín G, Perez-Miranda M. Fuentes-Valenzuela E, et al. Surg Endosc. 2023 Sep;37(9):6975-6982. doi: 10.1007/s00464-023-10199-3. Epub 2023 Jun 21. Surg Endosc. 2023. PMID: 37344754 - Fully covered metallic stents for anastomotic biliary strictures after living donor liver transplantation.
Komatsu N, Ozawa E, Fukushima M, Sawase H, Nagata K, Miuma S, Miyaaki H, Soyama A, Hidaka M, Eguchi S, Nakao K. Komatsu N, et al. DEN Open. 2023 Mar 27;3(1):e225. doi: 10.1002/deo2.225. eCollection 2023 Apr. DEN Open. 2023. PMID: 36998348 Free PMC article. - Post-ERCP pancreatitis occurs more frequently in self-expandable metallic stents than multiple plastic stents on benign biliary strictures: a meta-analysis.
Yang H, Yang Z, Hong J. Yang H, et al. Ann Med. 2022 Dec;54(1):2439-2449. doi: 10.1080/07853890.2022.2105395. Ann Med. 2022. PMID: 36799364 Free PMC article. - [Endoscopic management of complications in the hepatobiliary and pancreatic system and the tracheobronchial tree].
Kouladouros K, Kähler G. Kouladouros K, et al. Chirurgie (Heidelb). 2023 May;94(5):469-484. doi: 10.1007/s00104-022-01735-3. Epub 2022 Oct 21. Chirurgie (Heidelb). 2023. PMID: 36269350 German. - Brachytherapy Drainage Catheter and Chemotherapy for Unresectable Pancreatic Carcinoma Combined with Obstructive Jaundice.
Jiao D, Xu K, Mukhiya G, Liu Y, Wu K, Li Z, Ren J, Han X. Jiao D, et al. Front Oncol. 2022 Jul 14;12:941336. doi: 10.3389/fonc.2022.941336. eCollection 2022. Front Oncol. 2022. PMID: 35912255 Free PMC article.
References
- Gastrointest Endosc. 2018 Jan;87(1):131.e1-131.e13 - PubMed
- Endoscopy. 2013 Jul;45(7):567-70 - PubMed
- Liver Transpl. 2013 Jun;19(6):586-93 - PubMed
- Liver Transpl. 2008 Jan;14(1):73-80 - PubMed
- Endoscopy. 2005 Sep;37(9):857-63 - PubMed
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical