Mind the gap: Micro-expansion joints drastically decrease the bending of FIB-milled cryo-lamellae - PubMed (original) (raw)
. 2019 Dec 1;208(3):107389.
doi: 10.1016/j.jsb.2019.09.006. Epub 2019 Sep 16.
Affiliations
- PMID: 31536774
- DOI: 10.1016/j.jsb.2019.09.006
Free article
Mind the gap: Micro-expansion joints drastically decrease the bending of FIB-milled cryo-lamellae
Georg Wolff et al. J Struct Biol. 2019.
Free article
Abstract
Cryo-focused ion beam (FIB)-milling of biological samples can be used to generate thin electron-transparent slices from cells grown or deposited on EM grids. These so called cryo-lamellae allow high-resolution structural studies of the natural cellular environment by in situ cryo-electron tomography. However, the cryo-lamella workflow is a low-throughput technique and can easily be hindered by technical issues like the bending of the lamellae during the final cryo-FIB-milling steps. The severity of lamella bending seems to correlate with crinkling of the EM grid support film at cryogenic temperatures, which could generate tensions that may be transferred onto the thin lamella, leading to its bending and breakage. To protect the lamellae from such forces, we milled "micro-expansion joints" alongside the lamellae, creating gaps in the support that can act as physical buffers to safely absorb material motion. We demonstrate that the presence of micro-expansion joints drastically decreases bending of lamellae milled from eukaryotic cells grown and frozen on EM grids. Furthermore, we show that this adaptation does not create additional instabilities that could impede subsequent parts of the cryo-lamella workflow, as we obtained high-quality Volta phase plate tomograms revealing macromolecules in their natural structural context. The minimal additional effort required to implement micro-expansion joints in the cryo-FIB-milling workflow makes them a straightforward solution against cryo-lamella bending to increase the throughput of in situ structural biology studies.
Keywords: Cellular cryotomography; Cryo-FIB-milling; Cryo-electron tomography; Cryo-lamella; Frozen-hydrated cells; Lamella bending.
Copyright © 2019 The Authors. Published by Elsevier Inc. All rights reserved.
Similar articles
- Robust workflow and instrumentation for cryo-focused ion beam milling of samples for electron cryotomography.
Medeiros JM, Böck D, Weiss GL, Kooger R, Wepf RA, Pilhofer M. Medeiros JM, et al. Ultramicroscopy. 2018 Jul;190:1-11. doi: 10.1016/j.ultramic.2018.04.002. Epub 2018 Apr 6. Ultramicroscopy. 2018. PMID: 29655973 - Automated cryo-lamella preparation for high-throughput in-situ structural biology.
Buckley G, Gervinskas G, Taveneau C, Venugopal H, Whisstock JC, de Marco A. Buckley G, et al. J Struct Biol. 2020 May 1;210(2):107488. doi: 10.1016/j.jsb.2020.107488. Epub 2020 Feb 29. J Struct Biol. 2020. PMID: 32126263 - An improved cryo-FIB method for fabrication of frozen hydrated lamella.
Zhang J, Ji G, Huang X, Xu W, Sun F. Zhang J, et al. J Struct Biol. 2016 May;194(2):218-23. doi: 10.1016/j.jsb.2016.02.013. Epub 2016 Feb 12. J Struct Biol. 2016. PMID: 26876148 - Cryo-focused-ion-beam applications in structural biology.
Rigort A, Plitzko JM. Rigort A, et al. Arch Biochem Biophys. 2015 Sep 1;581:122-30. doi: 10.1016/j.abb.2015.02.009. Epub 2015 Feb 20. Arch Biochem Biophys. 2015. PMID: 25703192 Review. - Cryo-electron tomography on focused ion beam lamellae transforms structural cell biology.
Berger C, Premaraj N, Ravelli RBG, Knoops K, López-Iglesias C, Peters PJ. Berger C, et al. Nat Methods. 2023 Apr;20(4):499-511. doi: 10.1038/s41592-023-01783-5. Epub 2023 Mar 13. Nat Methods. 2023. PMID: 36914814 Review.
Cited by
- In situ structural determination of cyanobacterial phycobilisome-PSII supercomplex by STAgSPA strategy.
Zhang X, Xiao Y, You X, Sun S, Sui SF. Zhang X, et al. Nat Commun. 2024 Aug 22;15(1):7201. doi: 10.1038/s41467-024-51460-0. Nat Commun. 2024. PMID: 39169020 Free PMC article. - Waffle Method: A general and flexible approach for improving throughput in FIB-milling.
Kelley K, Raczkowski AM, Klykov O, Jaroenlak P, Bobe D, Kopylov M, Eng ET, Bhabha G, Potter CS, Carragher B, Noble AJ. Kelley K, et al. Nat Commun. 2022 Apr 6;13(1):1857. doi: 10.1038/s41467-022-29501-3. Nat Commun. 2022. PMID: 35387991 Free PMC article. - In situ structure of the red algal phycobilisome-PSII-PSI-LHC megacomplex.
You X, Zhang X, Cheng J, Xiao Y, Ma J, Sun S, Zhang X, Wang HW, Sui SF. You X, et al. Nature. 2023 Apr;616(7955):199-206. doi: 10.1038/s41586-023-05831-0. Epub 2023 Mar 15. Nature. 2023. PMID: 36922595 - Isolation, cryo-laser scanning confocal microscope imaging and cryo-FIB milling of mouse glutamatergic synaptosomes.
Gogoi P, Shiozaki M, Gouaux E. Gogoi P, et al. PLoS One. 2022 Aug 12;17(8):e0271799. doi: 10.1371/journal.pone.0271799. eCollection 2022. PLoS One. 2022. PMID: 35960737 Free PMC article. - Considerations of Antibody Geometric Constraints on NK Cell Antibody Dependent Cellular Cytotoxicity.
Murin CD. Murin CD. Front Immunol. 2020 Jul 30;11:1635. doi: 10.3389/fimmu.2020.01635. eCollection 2020. Front Immunol. 2020. PMID: 32849559 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous