Upper limit of normal titer for detection of antibodies to Legionella pneumophila by the microagglutination test - PubMed (original) (raw)

Upper limit of normal titer for detection of antibodies to Legionella pneumophila by the microagglutination test

G C Klein et al. J Clin Microbiol. 1979 Nov.

Abstract

An upper limit of normal microagglutination titer for the Knoxville strain of Legionella pneumophila was determined by testing 830 sera. The upper limit of normal titer was found to be 8; however, we suggest that when applied to single serum specimens a titer of 32 be considered the lowest titer suggestive of infection (not necessarily disease).

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Clin Microbiol. 1978 Sep;8(3):329-38 - PubMed
    1. Appl Microbiol. 1971 Jun;21(6):999-1001 - PubMed
    1. J Clin Microbiol. 1978 Apr;7(4):327-31 - PubMed

MeSH terms

Substances

LinkOut - more resources