Abstract
Attempts to optimize the quality of magnetic resonance images must balance the competing needs for high spatial resolution, high signal-to-noise ratio, a large number of sections, and a reasonable imaging time. These factors, which determine the ultimate image quality, are affected by a number of variables, including the field of view, the matrix and pixel size, choice of repetition time and echo time, section thickness, and the number of signals averaged. The manner in which these variables interrelate and their effect on the ultimate image quality are important in order to craft the most appropriate examination for each individual patient. A second major effect on soft-tissue contrast is the use of paramagnetic agents. The spectrum of utility of these agents within the central nervous system and the body is increasing. A large number of new agents are also being investigated, primarily for use outside the central nervous system.
Similar articles
- Fast multiplanar spoiled gradient-recalled imaging of the liver: pulse sequence optimization and comparison with spin-echo MR imaging.
Low RN, Francis IR, Herfkens RJ, Jeffrey RB Jr, Glazer GM, Foo TK, Shimakawa A, Pelc NJ. Low RN, et al. AJR Am J Roentgenol. 1993 Mar;160(3):501-9. doi: 10.2214/ajr.160.3.8381572. AJR Am J Roentgenol. 1993. PMID: 8381572 - [Methodologic variants on rapid MR imaging of the liver].
Langkowski JH, Heller M, Maas R, Kooijman H, Bücheler E. Langkowski JH, et al. Rofo. 1987 Nov;147(5):546-9. doi: 10.1055/s-2008-1048696. Rofo. 1987. PMID: 2825292 German. - Magnetic resonance imaging of musculoskeletal lesions: comparison of three fat-saturation pulse sequences.
Pui MH, Goh PS, Choo HF, Fok EC. Pui MH, et al. Australas Radiol. 1997 May;41(2):99-102. Australas Radiol. 1997. PMID: 9153802 - MR imaging of the breast. Imaging and tissue characterization without intravenous contrast.
Santyr GE. Santyr GE. Magn Reson Imaging Clin N Am. 1994 Nov;2(4):673-90. Magn Reson Imaging Clin N Am. 1994. PMID: 7489316 Review. - Technical advances in magnetic resonance imaging.
Bydder GM. Bydder GM. Curr Opin Neurol Neurosurg. 1992 Dec;5(6):854-8. Curr Opin Neurol Neurosurg. 1992. PMID: 1467578 Review.