Continuous fluorescence monitoring of rapid cycle DNA amplification - PubMed (original) (raw)
. 1997 Jan;22(1):130-1, 134-8.
doi: 10.2144/97221bi01.
Affiliations
- PMID: 8994660
- DOI: 10.2144/97221bi01
Free article
Continuous fluorescence monitoring of rapid cycle DNA amplification
C T Wittwer et al. Biotechniques. 1997 Jan.
Free article
Abstract
Rapid cycle DNA amplification was continuously monitored by three different fluorescence techniques. Fluorescence was monitored by (i) the double-strand-specific dye SYBR Green I, (ii) a decrease in fluorescein quenching by rhodamine after exonuclease cleavage of a dual-labeled hydrolysis probe and (iii) resonance energy transfer of fluorescein to Cy5 by adjacent hybridization probes. Fluorescence data acquired once per cycle provides rapid absolute quantification of initial template copy number. The sensitivity of SYBR Green I detection is limited by nonspecific product formation. Use of a single exonuclease hydrolysis probe or two adjacent hybridization probes offers increasing levels of specificity. In contrast to fluorescence measurement once per cycle, continuous monitoring throughout each cycle monitors the temperature dependence of fluorescence. The cumulative, irreversible signal of hydrolysis probes can be distinguished easily from the temperature-dependent, reversible signal of hybridization probes. By using SYBR Green I, product denaturation, annealing and extension can be followed within each cycle. Substantial product-to-product annealing occurs during later amplification cycles, suggesting that product annealing is a major cause of the plateau effect. Continuous within-cycle monitoring allows rapid optimization of amplification conditions and should be particularly useful in developing new, standardized clinical assays.
Comment in
- "Making it real" time.
Vrana KE. Vrana KE. Biotechniques. 2013 Jun;54(6):312-3. doi: 10.2144/000114042. Biotechniques. 2013. PMID: 23905171
Similar articles
- "Making it real" time.
Vrana KE. Vrana KE. Biotechniques. 2013 Jun;54(6):312-3. doi: 10.2144/000114042. Biotechniques. 2013. PMID: 23905171 - iFRET: an improved fluorescence system for DNA-melting analysis.
Howell WM, Jobs M, Brookes AJ. Howell WM, et al. Genome Res. 2002 Sep;12(9):1401-7. doi: 10.1101/gr.297202. Genome Res. 2002. PMID: 12213777 Free PMC article. - Quantification of low-copy transcripts by continuous SYBR Green I monitoring during amplification.
Morrison TB, Weis JJ, Wittwer CT. Morrison TB, et al. Biotechniques. 1998 Jun;24(6):954-8, 960, 962. Biotechniques. 1998. PMID: 9631186 - [Quantitative PCR in the diagnosis of Leishmania].
Mortarino M, Franceschi A, Mancianti F, Bazzocchi C, Genchi C, Bandi C. Mortarino M, et al. Parassitologia. 2004 Jun;46(1-2):163-7. Parassitologia. 2004. PMID: 15305709 Review. Italian. - Real-time multiplex PCR assays.
Wittwer CT, Herrmann MG, Gundry CN, Elenitoba-Johnson KS. Wittwer CT, et al. Methods. 2001 Dec;25(4):430-42. doi: 10.1006/meth.2001.1265. Methods. 2001. PMID: 11846612 Review.
Cited by
- The source of SYBR green master mix determines outcome of nucleic acid amplification reactions.
Yang J, Kemps-Mols B, Spruyt-Gerritse M, Anholts J, Claas F, Eikmans M. Yang J, et al. BMC Res Notes. 2016 Jun 4;9:292. doi: 10.1186/s13104-016-2093-4. BMC Res Notes. 2016. PMID: 27259280 Free PMC article. - Quantitative real-time PCR (qPCR) for Eimeria tenella replication--Implications for experimental refinement and animal welfare.
Nolan MJ, Tomley FM, Kaiser P, Blake DP. Nolan MJ, et al. Parasitol Int. 2015 Oct;64(5):464-70. doi: 10.1016/j.parint.2015.06.010. Epub 2015 Jul 2. Parasitol Int. 2015. PMID: 26141544 Free PMC article. - Development of a PCR Assay for Diagnosing Trematode (Opisthorchis and Haplorchis) Infections in Human Stools.
Lamaningao P, Kanda S, Laimanivong S, Shimono T, Darcy AW, Phyaluanglath A, Mishima N, Nishiyama T. Lamaningao P, et al. Am J Trop Med Hyg. 2017 Jan 11;96(1):221-228. doi: 10.4269/ajtmh.16-0165. Epub 2016 Nov 7. Am J Trop Med Hyg. 2017. PMID: 27821695 Free PMC article. - Fully automated, internally controlled quantification of hepatitis B Virus DNA by real-time PCR by use of the MagNA Pure LC and LightCycler instruments.
Leb V, Stöcher M, Valentine-Thon E, Hölzl G, Kessler H, Stekel H, Berg J. Leb V, et al. J Clin Microbiol. 2004 Feb;42(2):585-90. doi: 10.1128/JCM.42.2.585-590.2004. J Clin Microbiol. 2004. PMID: 14766820 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources