Possible application of transmitted laser light for the assessment of human pulpal vitality
T Sasano et al. Endod Dent Traumatol. 1997 Apr.
Abstract
The purpose of this study was to determine whether use of transmitted laser light would enable a better assessment of human pulpal vitality than back-scattered light does (LDF: laser Doppler flowmetry). The experiments were carried out on ten upper central incisors in six subjects aged 23-28 years; five of the teeth were vital with no restoration, and five were non-vital. For use with transmitted laser light, the fibers within the probe of a conventional LDF apparatus were used, one for transmitting light onto the buccal surface, the other for receiving it at the palatal surface of the same tooth. For LDF, the probe was fixed at the buccal surface. Blood flow was measured at three different locations on each experimental tooth: the incisal third, the center and the cervical third of the tooth crown. In non-vital teeth, 1) output signals with transmitted laser light all registered zero, and no oscillation could be seen in recordings from any location on the tooth, but 2) LDF signals were above zero, there were regular oscillations related to heart rate, and passive increases in blood flow (corresponding to blood pressure increases) were recorded from both the center and the cervical third of the tooth, indicating that LDF registered blood flow of non-pulpal origin. In vital teeth, LDF signals were significantly higher than in non-vital teeth at each location on the tooth. At the central site on vital teeth, the output signals for transmitted laser light were about twice those seen with LDF, and passive blood flow changes corresponding to blood pressure increases were more clearly observed. These results indicated that transmitted laser light would be useful for the assessment of tooth pulp vitality both because the blood flow signals did not include flow of non-pulpal origin, and because its output signals and response to blood flow changes were clear and could easily be monitored.
Similar articles
- Possible application of transmitted laser light for the assessment of human pulp vitality. Part 2. Increased laser power for enhanced detection of pulpal blood flow.
Sasano T, Onodera D, Hashimoto K, Iikubo M, Satoh-Kuriwada S, Shoji N, Miyahara T. Sasano T, et al. Dent Traumatol. 2005 Feb;21(1):37-41. doi: 10.1111/j.1600-9657.2004.00280.x. Dent Traumatol. 2005. PMID: 15660755 - Efficacy of laser Doppler flowmetry in determining pulp vitality of human teeth.
Ingólfsson AR, Tronstad L, Hersh EV, Riva CE. Ingólfsson AR, et al. Endod Dent Traumatol. 1994 Apr;10(2):83-7. doi: 10.1111/j.1600-9657.1994.tb00065.x. Endod Dent Traumatol. 1994. PMID: 8062812 - The effect of wavelength, bandwidth, and probe design and position on assessing the vitality of anterior teeth with laser Doppler flowmetry.
Roebuck EM, Evans DJ, Stirrups D, Strang R. Roebuck EM, et al. Int J Paediatr Dent. 2000 Sep;10(3):213-20. doi: 10.1046/j.1365-263x.2000.00194.x. Int J Paediatr Dent. 2000. PMID: 11310114 Clinical Trial. - Laser Doppler flowmetry in endodontics: a review.
Jafarzadeh H. Jafarzadeh H. Int Endod J. 2009 Jun;42(6):476-90. doi: 10.1111/j.1365-2591.2009.01548.x. Int Endod J. 2009. PMID: 19459999 Review. - Dental pulp neurophysiology: part 2. Current diagnostic tests to assess pulp vitality.
Abd-Elmeguid A, Yu DC. Abd-Elmeguid A, et al. J Can Dent Assoc. 2009 Mar;75(2):139-43. J Can Dent Assoc. 2009. PMID: 19267966 Review.
Cited by
- Dental pulp testing: a review.
Chen E, Abbott PV. Chen E, et al. Int J Dent. 2009;2009:365785. doi: 10.1155/2009/365785. Epub 2009 Nov 12. Int J Dent. 2009. PMID: 20339575 Free PMC article.