Infrared microspectroscopic imaging of biomineralized tissues using a mercury-cadmium-telluride focal-plane array detector - PubMed (original) (raw)
Affiliations
- PMID: 9551643
Infrared microspectroscopic imaging of biomineralized tissues using a mercury-cadmium-telluride focal-plane array detector
C Marcott et al. Cell Mol Biol (Noisy-le-grand). 1998 Feb.
Abstract
A 64 x 64 mercury-cadmium-telluride focal-plane array detector attached to a Fourier transform infrared microscope was used to spectroscopically image 5 microm sections of canine alveolar bone tissue in the fingerprint region of the infrared spectrum. By ratioing the relative intensities of specific bands across the images, it is possible to obtain spatial distributions of the mineral-to-matrix ratio and mineral maturity as a function of distance from an osteon.
Similar articles
- Infrared microspectroscopic imaging using a large radius germanium internal reflection element and a focal plane array detector.
Patterson BM, Havrilla GJ, Marcott C, Story GM. Patterson BM, et al. Appl Spectrosc. 2007 Nov;61(11):1147-52. doi: 10.1366/000370207782596969. Appl Spectrosc. 2007. PMID: 18028692 - Performance and application of a new planar array infrared spectrograph operating in the mid-infrared (2000-975 cm(-1)) fingerprint region.
Pellerin C, Snively CM, Chase DB, Rabolt JF. Pellerin C, et al. Appl Spectrosc. 2004 Jun;58(6):639-46. doi: 10.1366/000370204873060. Appl Spectrosc. 2004. PMID: 15198813 - Infrared microscopic imaging of bone: spatial distribution of CO3(2-).
Ou-Yang H, Paschalis EP, Mayo WE, Boskey AL, Mendelsohn R. Ou-Yang H, et al. J Bone Miner Res. 2001 May;16(5):893-900. doi: 10.1359/jbmr.2001.16.5.893. J Bone Miner Res. 2001. PMID: 11341334 - Experimental aspects of asynchronous rapid-scan fourier transform infrared imaging.
Snively CM, Lauterbach J. Snively CM, et al. Appl Spectrosc. 2005 Sep;59(9):1075-81. doi: 10.1366/0003702055012609. Appl Spectrosc. 2005. PMID: 16197629 Review. - Infrared analysis of bone in health and disease.
Boskey A, Mendelsohn R. Boskey A, et al. J Biomed Opt. 2005 May-Jun;10(3):031102. doi: 10.1117/1.1922927. J Biomed Opt. 2005. PMID: 16229627 Review.
Cited by
- Progress on AlGaN-based solar-blind ultraviolet photodetectors and focal plane arrays.
Cai Q, You H, Guo H, Wang J, Liu B, Xie Z, Chen D, Lu H, Zheng Y, Zhang R. Cai Q, et al. Light Sci Appl. 2021 Apr 30;10(1):94. doi: 10.1038/s41377-021-00527-4. Light Sci Appl. 2021. PMID: 33931580 Free PMC article. Review. - Measuring bone quality.
Torres-del-Pliego E, Vilaplana L, Güerri-Fernández R, Diez-Pérez A. Torres-del-Pliego E, et al. Curr Rheumatol Rep. 2013 Nov;15(11):373. doi: 10.1007/s11926-013-0373-8. Curr Rheumatol Rep. 2013. PMID: 24072603 Review. - The effects of GATA-1 and NF-E2 deficiency on bone biomechanical, biochemical, and mineral properties.
Kacena MA, Gundberg CM, Kacena WJ 3rd, Landis WJ, Boskey AL, Bouxsein ML, Horowitz MC. Kacena MA, et al. J Cell Physiol. 2013 Jul;228(7):1594-600. doi: 10.1002/jcp.24322. J Cell Physiol. 2013. PMID: 23359245 Free PMC article. - Infrared assessment of bone quality: a review.
Paschalis EP, Mendelsohn R, Boskey AL. Paschalis EP, et al. Clin Orthop Relat Res. 2011 Aug;469(8):2170-8. doi: 10.1007/s11999-010-1751-4. Clin Orthop Relat Res. 2011. PMID: 21210314 Free PMC article. Review. - Fourier transform infrared analysis and bone.
Paschalis EP. Paschalis EP. Osteoporos Int. 2009 Jun;20(6):1043-7. doi: 10.1007/s00198-009-0857-6. Osteoporos Int. 2009. PMID: 19340508 No abstract available.
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources