The Cyberknife: a frameless robotic system for radiosurgery - PubMed (original) (raw)
. 1997;69(1-4 Pt 2):124-8.
doi: 10.1159/000099863.
Affiliations
- PMID: 9711744
- DOI: 10.1159/000099863
The Cyberknife: a frameless robotic system for radiosurgery
J R Adler Jr et al. Stereotact Funct Neurosurg. 1997.
Abstract
The Cyberknife is a unique instrument for performing frameless stereotactic radiosurgery. Rather than using rigid immobilization, the Cyberknife relies on an image-to-image correlation algorithm for target localization. Furthermore, the system utilizes a novel, light-weight, high-energy radiation source. The authors describe the technical specifications of the Cyberknife and summarize the initial clinical experience.
Similar articles
- [CyberKnife robotic radiosurgery].
Saito K, Kajiwara K, Ishihara H, Nomura S, Suzuki M. Saito K, et al. No To Shinkei. 2006 Apr;58(4):277-88. No To Shinkei. 2006. PMID: 16681256 Review. Japanese. No abstract available. - Frameless image-guided intracranial and extracranial radiosurgery using the Cyberknife robotic system.
Gibbs IC. Gibbs IC. Cancer Radiother. 2006 Sep;10(5):283-7. doi: 10.1016/j.canrad.2006.05.013. Epub 2006 Jul 21. Cancer Radiother. 2006. PMID: 16859948 - Image-guided stereotactic radiosurgery for treatment of spinal hemangioblastoma.
Pan J, Ho AL, D'Astous M, Sussman ES, Thompson PA, Tayag AT, Pangilinan L, Soltys SG, Gibbs IC, Chang SD. Pan J, et al. Neurosurg Focus. 2017 Jan;42(1):E12. doi: 10.3171/2016.10.FOCUS16361. Neurosurg Focus. 2017. PMID: 28041328 - An analysis of the accuracy of the CyberKnife: a robotic frameless stereotactic radiosurgical system.
Chang SD, Main W, Martin DP, Gibbs IC, Heilbrun MP. Chang SD, et al. Neurosurgery. 2003 Jan;52(1):140-6; discussion 146-7. doi: 10.1097/00006123-200301000-00018. Neurosurgery. 2003. PMID: 12493111 - [CyberKnife image-guided robotic frameless fractionated stereotactic radiotherapy for metastatic brain tumors].
Ogita M, Kameda N, Fujimori T, Matumoto T, Nakamura K, Fujimoto T. Ogita M, et al. Nihon Rinsho. 2005 Sep;63 Suppl 9:633-8. Nihon Rinsho. 2005. PMID: 16201592 Review. Japanese. No abstract available.
Cited by
- Prospective evaluation of spinal cord and cauda equina dose constraints using cone beam computed tomography (CBCT) image guidance for spine radiosurgery.
Gerszten PC, Quader M, Novotny J Jr, Flickinger JC. Gerszten PC, et al. J Radiosurg SBRT. 2011;1(3):197-202. J Radiosurg SBRT. 2011. PMID: 29296317 Free PMC article. - Semi-Autonomous Electrosurgery for Tumor Resection Using a Multi-Degree of Freedom Electrosurgical Tool and Visual Servoing.
Opfermann JD, Leonard S, Decker RS, Uebele NA, Bayne CE, Joshi AS, Krieger A. Opfermann JD, et al. Rep U S. 2017;2017:3653-3659. doi: 10.1109/IROS.2017.8206210. Epub 2017 Dec 14. Rep U S. 2017. PMID: 29503760 Free PMC article. - CyberKnife robotic radiosurgery in the multimodal management of acromegaly patients with invasive macroadenoma: a single center's experience.
Sala E, Moore JM, Amorin A, Martinez H Jr, Bhowmik AC, Lamsam L, Chang S, Soltys SG, Katznelson L, Harsh GR. Sala E, et al. J Neurooncol. 2018 Jun;138(2):291-298. doi: 10.1007/s11060-018-2793-9. Epub 2018 Feb 10. J Neurooncol. 2018. PMID: 29429125 - CyberKnife Radiosurgery of Skull-base Tumors: A UK Center Experience.
Wilson HP, Price PM, Ashkan K, Edwards A, Green MM, Cross T, Beaney RP, Davies R, Sibtain A, Plowman NP, Goldsmith C Dr. Wilson HP, et al. Cureus. 2018 Mar 27;10(3):e2380. doi: 10.7759/cureus.2380. Cureus. 2018. PMID: 29805949 Free PMC article. - Dosimetric characterization and behaviour in small X-ray fields of a microchamber and a plastic scintillator detector.
Pasquino M, Cutaia C, Radici L, Valzano S, Gino E, Cavedon C, Stasi M. Pasquino M, et al. Br J Radiol. 2017 Jan;90(1069):20160596. doi: 10.1259/bjr.20160596. Epub 2016 Nov 9. Br J Radiol. 2017. PMID: 27826990 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources