Gastone Ciuti | Scuola Superiore Sant'Anna (original) (raw)
Papers by Gastone Ciuti
Endoscopy international open, 2018
Polyp size measurement is an important diagnostic step during gastrointestinal endoscopy, and is... more Polyp size measurement is an important diagnostic step during gastrointestinal endoscopy, and is mainly performed by visual inspection. However, lack of depth perception and objective reference points are acknowledged factors contributing to measurement errors in polyp size. In this paper, we describe the proof-of-concept of a polyp measurement device based on structured light technology for future endoscopes. Measurement accuracy, time, user confidence, and satisfaction were evaluated for polyp size assessment by (a) visual inspection, (b) open biopsy forceps of known size, (c) ruled snare, and (d) structured light probe, for a total of 392 independent polyp measurements in ex vivo porcine stomachs. Visual assessment resulted in a median estimation error of 2.2 mm, IQR = 2.6 mm. The proposed probe can reduce the error to 1.5 mm, IQR = 1.67 mm ( = 0.002, 95 %CI) and its performance was found to be statistically similar to using forceps for reference ( = 0.81, 95 %CI) or ruled s...
Science Robotics, 2021
To achieve a seamless human-robot collaboration, it is crucial that robots express their intentio... more To achieve a seamless human-robot collaboration, it is crucial that robots express their intentions without perturbating or interrupting the task that a human partner is performing at that moment. Although it has not received much attention so far, this issue is important when robots assist humans in physical and manipulation tasks. The main question addressed here is whether there is a more appropriate time to inform a human partner that a robot is requesting to pass them an object. This question is posed in a reference scenario where human individuals are involved in a continuous pick-and-place task that cannot be interrupted. Our findings showed that providing a cue at the beginning of a reach-to-grasp movement could severely interfere with the ongoing human action, increasing the number of errors made by humans, slowing down and degrading the smoothness of their arm movement, and deflecting their gaze. These disruptive interferences strongly decreased, until they disappeared, when the robot provided the cue to the human partners shortly after the participants picked up an object, identifying this as the best signaling timing. The results of this work showed how the signaling timing may have a decisive influence on the performances of the human-robot teamwork and contribute to understanding the mechanisms underpinning the phenomenon of cognitive-motor interference in humans.
MDPI Cancers, 2020
Upper gastrointestinal (UGI) tract pathology is common worldwide. With recent advancements in rob... more Upper gastrointestinal (UGI) tract pathology is common worldwide. With recent advancements in robotics, innovative diagnostic and treatment devices have been developed and several translational attempts made. This review paper aims to provide a highly pictorial critical review of robotic gastroscopes, so that clinicians and researchers can obtain a swift and comprehensive overview of key technologies and challenges. Therefore, the paper presents robotic gastroscopes, either commercial or at a progressed technology readiness level. Among them, we show tethered and wireless gastroscopes, as well as devices aimed for UGI surgery. The technological features of these instruments, as well as their clinical adoption and performance, are described and compared. Although the existing endoscopic devices have thus far provided substantial improvements in the effectiveness of diagnosis and treatment, there are certain aspects that represent unwavering predicaments of the current gastroenterology practice. A detailed list includes difficulties and risks, such as transmission of communicable diseases (e.g., COVID-19) due to the doctor-patient proximity, unchanged learning curves, variable detection rates, procedure-related adverse events, endoscopists' and nurses' burnouts, limited human and/or material resources, and patients' preferences to choose non-invasive options that further interfere with the successful implementation and adoption of routine screening. The combination of robotics and artificial intelligence, as well as remote telehealth endoscopy services, are also discussed, as viable solutions to improve existing platforms for diagnosis and treatment are emerging.
MDPI Sensors, 2020
The capsule endoscopy robot can only use monocular vision due to the dimensional limit. To improv... more The capsule endoscopy robot can only use monocular vision due to the dimensional limit. To improve the depth perception of the monocular capsule endoscopy robot, this paper proposes a photometric stereo-based depth map reconstruction method. First, based on the characteristics of the capsule endoscopy robot system, a photometric stereo framework is established. Then, by combining the specular property and Lambertian property of the object surface, the depth of the specular highlight point is estimated, and the depth map of the whole object surface is reconstructed by a forward upwind scheme. To evaluate the precision of the depth estimation of the specular highlight region and the depth map reconstruction of the object surface, simulations and experiments are implemented with synthetic images and pig colon tissue, respectively. The results of the simulations and experiments show that the proposed method provides good precision for depth map reconstruction in monocular capsule endoscopy.
Abstract: Background and Aims: Colorectal cancer (CRC) is a major cause of morbidity and mortalit... more Abstract: Background and Aims: Colorectal cancer (CRC) is a major cause of morbidity and mortality worldwide. Despite offering a prime paradigm for screening, CRC screening is often hampered by invasiveness. Endoo is a potentially painless colonoscopy method with an active locomotion tethered capsule offering diagnostic and therapeutic capabilities. Materials and Methods: The Endoo system comprises a soft-tethered capsule, which embeds a permanent magnet controlled by an external robot equipped with a second permanent magnet. Capsule navigation is achieved via closed-loop interaction between the two magnets. Ex-vivo tests were conducted by endoscopy experts and trainees to evaluate the basic key features, usability, and compliance in comparison with conventional colonoscopy (CC) in feasibility and pilot studies. Results: Endoo showed a 100% success rate in operating channel and target approach tests. Progression of the capsule was feasible and repeatable. The magnetic link was lost an average of 1.28 times per complete procedure but was restored in 100% of cases. The peak value of interaction forces was higher in the CC group than the Endoo group (4.12N vs. 1.17N). The cumulative interaction forces over time were higher in the CC group than the Endoo group between the splenic flexure and mid-transverse colon (16.53Ns vs. 1.67Ns, p < 0.001), Cancers 2020, 12, 2485 2 of 15 as well as between the hepatic flexure and cecum (28.77Ns vs. 2.47Ns, p = 0.005). The polyp detection rates were comparable between groups (9.1 ± 0.9% vs. 8.7 ± 0.9%, CC and Endoo respectively, per procedure). Robotic colonoscopies were completed in 67% of the procedures performed with Endoo (53% experts and 100% trainees). Conclusions: Endoo allows smoother navigation than CC and possesses comparable features. Although further research is needed, magnetic capsule colonoscopy demonstrated promising results compared to CC.
Flexible colonoscopy remains the prime mean of screening for colorectal cancer (CRC) and the gold... more Flexible colonoscopy remains the prime mean of screening for colorectal cancer (CRC) and the gold standard of all population-based screening pathways around the world. Almost 60% of CRC deaths could be prevented with screening. However, colonoscopy attendance rates are affected by discomfort, fear of pain and embarrassment or loss of control during the procedure. Moreover, the emergence and global thread of new communicable diseases might seriously affect the functioning of contemporary centres performing gastrointestinal endoscopy. Innovative solutions are needed: artificial intelligence (AI) and physical robotics will drastically contribute for the future of the healthcare services. The translation of robotic technologies from traditional surgery to minimally invasive endoscopic interventions is an emerging field, mainly challenged by the tough requirements for miniaturization. Pioneering approaches for robotic colonoscopy have been reported in the nineties, with the appearance of inchworm-like devices. Since then, robotic colonoscopes with assistive functionalities have become commercially available. Research prototypes promise enhanced accessibility and flexibility for future therapeutic interventions, even via autonomous or robotic-assisted agents, such as robotic capsules. Furthermore, the pairing of such endoscopic systems with AI-enabled image analysis and recognition methods promises enhanced diagnostic yield. By assembling a multidisciplinary team of engineers and endoscopists, the paper aims to provide a contemporary and highly-pictorial critical review for robotic colonoscopes, hence providing clinicians and researchers with a glimpse of the major changes and challenges that lie ahead.
2015 International Conference on Information and Communication Technology Research (ICTRC), 2015
2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob), 2012
Endoscopy international open, 2018
Polyp size measurement is an important diagnostic step during gastrointestinal endoscopy, and is... more Polyp size measurement is an important diagnostic step during gastrointestinal endoscopy, and is mainly performed by visual inspection. However, lack of depth perception and objective reference points are acknowledged factors contributing to measurement errors in polyp size. In this paper, we describe the proof-of-concept of a polyp measurement device based on structured light technology for future endoscopes. Measurement accuracy, time, user confidence, and satisfaction were evaluated for polyp size assessment by (a) visual inspection, (b) open biopsy forceps of known size, (c) ruled snare, and (d) structured light probe, for a total of 392 independent polyp measurements in ex vivo porcine stomachs. Visual assessment resulted in a median estimation error of 2.2 mm, IQR = 2.6 mm. The proposed probe can reduce the error to 1.5 mm, IQR = 1.67 mm ( = 0.002, 95 %CI) and its performance was found to be statistically similar to using forceps for reference ( = 0.81, 95 %CI) or ruled s...
Science Robotics, 2021
To achieve a seamless human-robot collaboration, it is crucial that robots express their intentio... more To achieve a seamless human-robot collaboration, it is crucial that robots express their intentions without perturbating or interrupting the task that a human partner is performing at that moment. Although it has not received much attention so far, this issue is important when robots assist humans in physical and manipulation tasks. The main question addressed here is whether there is a more appropriate time to inform a human partner that a robot is requesting to pass them an object. This question is posed in a reference scenario where human individuals are involved in a continuous pick-and-place task that cannot be interrupted. Our findings showed that providing a cue at the beginning of a reach-to-grasp movement could severely interfere with the ongoing human action, increasing the number of errors made by humans, slowing down and degrading the smoothness of their arm movement, and deflecting their gaze. These disruptive interferences strongly decreased, until they disappeared, when the robot provided the cue to the human partners shortly after the participants picked up an object, identifying this as the best signaling timing. The results of this work showed how the signaling timing may have a decisive influence on the performances of the human-robot teamwork and contribute to understanding the mechanisms underpinning the phenomenon of cognitive-motor interference in humans.
MDPI Cancers, 2020
Upper gastrointestinal (UGI) tract pathology is common worldwide. With recent advancements in rob... more Upper gastrointestinal (UGI) tract pathology is common worldwide. With recent advancements in robotics, innovative diagnostic and treatment devices have been developed and several translational attempts made. This review paper aims to provide a highly pictorial critical review of robotic gastroscopes, so that clinicians and researchers can obtain a swift and comprehensive overview of key technologies and challenges. Therefore, the paper presents robotic gastroscopes, either commercial or at a progressed technology readiness level. Among them, we show tethered and wireless gastroscopes, as well as devices aimed for UGI surgery. The technological features of these instruments, as well as their clinical adoption and performance, are described and compared. Although the existing endoscopic devices have thus far provided substantial improvements in the effectiveness of diagnosis and treatment, there are certain aspects that represent unwavering predicaments of the current gastroenterology practice. A detailed list includes difficulties and risks, such as transmission of communicable diseases (e.g., COVID-19) due to the doctor-patient proximity, unchanged learning curves, variable detection rates, procedure-related adverse events, endoscopists' and nurses' burnouts, limited human and/or material resources, and patients' preferences to choose non-invasive options that further interfere with the successful implementation and adoption of routine screening. The combination of robotics and artificial intelligence, as well as remote telehealth endoscopy services, are also discussed, as viable solutions to improve existing platforms for diagnosis and treatment are emerging.
MDPI Sensors, 2020
The capsule endoscopy robot can only use monocular vision due to the dimensional limit. To improv... more The capsule endoscopy robot can only use monocular vision due to the dimensional limit. To improve the depth perception of the monocular capsule endoscopy robot, this paper proposes a photometric stereo-based depth map reconstruction method. First, based on the characteristics of the capsule endoscopy robot system, a photometric stereo framework is established. Then, by combining the specular property and Lambertian property of the object surface, the depth of the specular highlight point is estimated, and the depth map of the whole object surface is reconstructed by a forward upwind scheme. To evaluate the precision of the depth estimation of the specular highlight region and the depth map reconstruction of the object surface, simulations and experiments are implemented with synthetic images and pig colon tissue, respectively. The results of the simulations and experiments show that the proposed method provides good precision for depth map reconstruction in monocular capsule endoscopy.
Abstract: Background and Aims: Colorectal cancer (CRC) is a major cause of morbidity and mortalit... more Abstract: Background and Aims: Colorectal cancer (CRC) is a major cause of morbidity and mortality worldwide. Despite offering a prime paradigm for screening, CRC screening is often hampered by invasiveness. Endoo is a potentially painless colonoscopy method with an active locomotion tethered capsule offering diagnostic and therapeutic capabilities. Materials and Methods: The Endoo system comprises a soft-tethered capsule, which embeds a permanent magnet controlled by an external robot equipped with a second permanent magnet. Capsule navigation is achieved via closed-loop interaction between the two magnets. Ex-vivo tests were conducted by endoscopy experts and trainees to evaluate the basic key features, usability, and compliance in comparison with conventional colonoscopy (CC) in feasibility and pilot studies. Results: Endoo showed a 100% success rate in operating channel and target approach tests. Progression of the capsule was feasible and repeatable. The magnetic link was lost an average of 1.28 times per complete procedure but was restored in 100% of cases. The peak value of interaction forces was higher in the CC group than the Endoo group (4.12N vs. 1.17N). The cumulative interaction forces over time were higher in the CC group than the Endoo group between the splenic flexure and mid-transverse colon (16.53Ns vs. 1.67Ns, p < 0.001), Cancers 2020, 12, 2485 2 of 15 as well as between the hepatic flexure and cecum (28.77Ns vs. 2.47Ns, p = 0.005). The polyp detection rates were comparable between groups (9.1 ± 0.9% vs. 8.7 ± 0.9%, CC and Endoo respectively, per procedure). Robotic colonoscopies were completed in 67% of the procedures performed with Endoo (53% experts and 100% trainees). Conclusions: Endoo allows smoother navigation than CC and possesses comparable features. Although further research is needed, magnetic capsule colonoscopy demonstrated promising results compared to CC.
Flexible colonoscopy remains the prime mean of screening for colorectal cancer (CRC) and the gold... more Flexible colonoscopy remains the prime mean of screening for colorectal cancer (CRC) and the gold standard of all population-based screening pathways around the world. Almost 60% of CRC deaths could be prevented with screening. However, colonoscopy attendance rates are affected by discomfort, fear of pain and embarrassment or loss of control during the procedure. Moreover, the emergence and global thread of new communicable diseases might seriously affect the functioning of contemporary centres performing gastrointestinal endoscopy. Innovative solutions are needed: artificial intelligence (AI) and physical robotics will drastically contribute for the future of the healthcare services. The translation of robotic technologies from traditional surgery to minimally invasive endoscopic interventions is an emerging field, mainly challenged by the tough requirements for miniaturization. Pioneering approaches for robotic colonoscopy have been reported in the nineties, with the appearance of inchworm-like devices. Since then, robotic colonoscopes with assistive functionalities have become commercially available. Research prototypes promise enhanced accessibility and flexibility for future therapeutic interventions, even via autonomous or robotic-assisted agents, such as robotic capsules. Furthermore, the pairing of such endoscopic systems with AI-enabled image analysis and recognition methods promises enhanced diagnostic yield. By assembling a multidisciplinary team of engineers and endoscopists, the paper aims to provide a contemporary and highly-pictorial critical review for robotic colonoscopes, hence providing clinicians and researchers with a glimpse of the major changes and challenges that lie ahead.
2015 International Conference on Information and Communication Technology Research (ICTRC), 2015
2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob), 2012