LEGRI has been operating successfully on MINISAT-01 since its switch-on the 22nd of May 1997. HouseKeeping (HK) data have been continuously receivedfor nearly two years by LEGRI SOC in Valencia, and subsequently checked on adaily basis and then stored for long term monitoring analysis.LEGRI HouseKeeping data include three critical operating parameters:temperature, power and polarisation voltages. Six temperature sensors arespread over the different LEGRI units: Detector Unit, Data Processing Unit,High Voltage Unit and Star Sensor. Voltages are measured at eight differentpoints. Detector Unit temperature and polarisation voltage are thecritical parameters for LEGRI operation. Solid state detectors aresensitive to changes not only in polarisation but also in temperature.Around one and a half million of measurements for each of the HK fourteen parameters have been recorded and analysed. The data show a very remarkablestability, within the expected margins, and the averages are very close to theoptimal design values. Special attention has been paid to the detectorpolarisation voltages analysis with a mean value of 286 ± 2 V when the detectors are operating. Thermal control over all the LEGRI units shows a remarkable stability in their temperatures.On the detector plane a mean value of Tdet = 13 ± 2 °C has been found.We can therefore conclude that LEGRI as a system has been operating withinits optimal design conditions. We also want to point out the excellentperformance of the MINISAT-01 thermal control system.