Dilan Arias Montañez | Universidad Santo Tomás, Colombia (original) (raw)
Uploads
Papers by Dilan Arias Montañez
Canadian Geotechnical Journal, 1993
Laboratory experiments on undisturbed specimens of a large number of soft clay deposits, as well ... more Laboratory experiments on undisturbed specimens of a large number of soft clay deposits, as well as previous measurements on clays and granular soils, were used to examine and explain the magnitude and behavior of the coefficient of earth pressure at rest, K0: (i) after sedimentation – primary consolidation, (ii) during secondary-compression aging, (iii) after active or passive preshearing away from the laterally constrained condition, (iv) during a decrease in effective vertical stress, and (v) during an increase in effective vertical stress in the recompression or compression range, in terms of [Formula: see text], the slope of the effective horizontal [Formula: see text] versus effective vertical[Formula: see text] stress path. The behavior of K0 is explained using the concept of mobilized angle of friction in laterally constrained deformation condition. The Jaky equation provides, in terms of the angle of internal friction, a good estimate of K0 of sedimented, normally consolida...
contenedor de raices, 2017
Asunto: Concepto Contenedores de Raíces Respetado Ingeniero: Por medio del presente me permito pr... more Asunto: Concepto Contenedores de Raíces Respetado Ingeniero: Por medio del presente me permito presentar el concepto relacionado con los Contenedores de Raíces, esto en atención a la consulta remitida por correo electrónico por parte del arquitecto Pedro Lennin Aldana, el pasado 18 de Junio de 2016, que se cita a continuación: "Con el fin de dar inicio a la construcción de los contenedores de raíz del proyecto, solicitamos aclarar y/o justificar cual debe ser el elemento a construirse ya que de acuerdo a los planos de detalle DV-UR-DP-07-V2, (ver adjunto) estos contenedores tienen unas dimensiones de 1.20 X 2.00 X 1.10 que corresponden completamente a la modulación de los andenes del proyecto. Pero haciendo la revisión del presupuesto oficial, este nos indica que serán unos contenedores de 1.60 X 1.60 X 1.10 con unas características e insumos bien distintos. Por tal razón solicitamos una justificación de este cambio que nos permita generar un PRECIO UNITARIO NUEVO para la realización de esta actividad." En atención a ello me permito presentar las razones que motivaron el cambio durante el desarrollo de los estudios y diseños y; que al parecer son desconocidas por el equipo en obra: los estudios y diseños de la Avd. Ciudad de Cali se desarrollaron bajo el marco definido en la Cartilla de Andenes Decreto Distrital 602 de 2007. Esta determina las características, especificaciones e insumos de estos elementos en el espacio público entre ellos las tipologías B-20; B-25 y B-26. durante el desarrollo de los estudios y diseños se determinó tras la implementación del diseño geométrico, que dadas las secciones de andenes resultantes, las franjas de circulación peatonal no cumplirían con los mínimos admisibles determinados por la Cartilla de Andenes. Esta situación obligó a considerar el uso potencial del Contenedor de Raíces Tipo B-20 (1.20*1.20*1.20m)
Canadian Geotechnical Journal, 1993
Laboratory experiments on undisturbed specimens of a large number of soft clay deposits, as well ... more Laboratory experiments on undisturbed specimens of a large number of soft clay deposits, as well as previous measurements on clays and granular soils, were used to examine and explain the magnitude and behavior of the coefficient of earth pressure at rest, K0: (i) after sedimentation – primary consolidation, (ii) during secondary-compression aging, (iii) after active or passive preshearing away from the laterally constrained condition, (iv) during a decrease in effective vertical stress, and (v) during an increase in effective vertical stress in the recompression or compression range, in terms of [Formula: see text], the slope of the effective horizontal [Formula: see text] versus effective vertical[Formula: see text] stress path. The behavior of K0 is explained using the concept of mobilized angle of friction in laterally constrained deformation condition. The Jaky equation provides, in terms of the angle of internal friction, a good estimate of K0 of sedimented, normally consolida...
contenedor de raices, 2017
Asunto: Concepto Contenedores de Raíces Respetado Ingeniero: Por medio del presente me permito pr... more Asunto: Concepto Contenedores de Raíces Respetado Ingeniero: Por medio del presente me permito presentar el concepto relacionado con los Contenedores de Raíces, esto en atención a la consulta remitida por correo electrónico por parte del arquitecto Pedro Lennin Aldana, el pasado 18 de Junio de 2016, que se cita a continuación: "Con el fin de dar inicio a la construcción de los contenedores de raíz del proyecto, solicitamos aclarar y/o justificar cual debe ser el elemento a construirse ya que de acuerdo a los planos de detalle DV-UR-DP-07-V2, (ver adjunto) estos contenedores tienen unas dimensiones de 1.20 X 2.00 X 1.10 que corresponden completamente a la modulación de los andenes del proyecto. Pero haciendo la revisión del presupuesto oficial, este nos indica que serán unos contenedores de 1.60 X 1.60 X 1.10 con unas características e insumos bien distintos. Por tal razón solicitamos una justificación de este cambio que nos permita generar un PRECIO UNITARIO NUEVO para la realización de esta actividad." En atención a ello me permito presentar las razones que motivaron el cambio durante el desarrollo de los estudios y diseños y; que al parecer son desconocidas por el equipo en obra: los estudios y diseños de la Avd. Ciudad de Cali se desarrollaron bajo el marco definido en la Cartilla de Andenes Decreto Distrital 602 de 2007. Esta determina las características, especificaciones e insumos de estos elementos en el espacio público entre ellos las tipologías B-20; B-25 y B-26. durante el desarrollo de los estudios y diseños se determinó tras la implementación del diseño geométrico, que dadas las secciones de andenes resultantes, las franjas de circulación peatonal no cumplirían con los mínimos admisibles determinados por la Cartilla de Andenes. Esta situación obligó a considerar el uso potencial del Contenedor de Raíces Tipo B-20 (1.20*1.20*1.20m)