Robert Burks | University of Utah (original) (raw)

Papers by Robert Burks

Research paper thumbnail of A Prospective Randomized Clinical Trial Comparing Arthroscopic Single-and Double-Row Rotator Cuff Repair

American Journal of Sports Medicine, 2009

Arthroscopic rotator cuff repair is becoming increasingly popular with a significant amount of re... more Arthroscopic rotator cuff repair is becoming increasingly popular with a significant amount of research being performed evaluating techniques and outcomes. Most studies have used a single row of anchors for attaching the rotator cuff tendon to bone when doing the repair. With the recent emphasis on anatomy of the rotator cuff footprint, techniques attaching the rotator cuff tendon over more of its normal footprint have gained popularity. § In vitro studies have analyzed repair techniques using various combinations

Research paper thumbnail of Patient- and Procedure-Specific Variables Driving Total Direct Costs of Outpatient Anterior Cruciate Ligament Reconstruction

Orthopaedic journal of sports medicine, 2018

Few studies have investigated the influence of patient-specific variables or procedure-specific f... more Few studies have investigated the influence of patient-specific variables or procedure-specific factors on the overall cost of anterior cruciate ligament reconstruction (ACLR) in an ambulatory surgery setting. To determine patient- and procedure-specific factors influencing the overall direct cost of outpatient arthroscopic ACLR utilizing a unique value-driven outcomes (VDO) tool. Cohort study (economic and decision analysis); Level of evidence, 3. All ACLRs performed by 4 surgeons over 2 years were retrospectively reviewed. Cost data were derived from the VDO tool. Patient-specific variables included age, body mass index, comorbidities, American Society of Anesthesiologists (ASA) classification, smoking status, preoperative Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function Computerized Adaptive Testing (PF-CAT) score, and preoperative Single Assessment Numeric Evaluation (SANE) score. Procedure-specific variables included graft type, revision statu...

Research paper thumbnail of Biomechanical Comparison of Transosseous Knotless Rotator Cuff Repair Versus Transosseous Equivalent Repair: Half The Anchors With Equivalent Biomechanics?

Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association, 2018

To compare the biomechanics of a transosseous equivalent (TOE) repair using medial and lateral an... more To compare the biomechanics of a transosseous equivalent (TOE) repair using medial and lateral anchors with tape to a transosseous knotless (TOK) tape repair with only laterally placed intraosseous anchors. One of 2 different repairs were performed on 8 paired specimens: (1) transosseous equivalent (TOE) tape repair or (2) transosseous knotless (TOK) tape repair. Specimens were mounted on a materials testing machine and loaded in uniaxial tension to measure cyclic construct gap formation, followed by failure testing. Paired t tests were used to compare gapping, ultimate stiffness, and failure loads. Fisher exact test was used to compare modes of failure (soft tissue failure vs construct failure). Peak cyclic gapping, failure stiffness, and ultimate failure loads did not differ between TOE and TOK repairs (P = .140 for gapping, P = .106 for stiffness, and P = .672 for peak failure loads). All TOK repairs failed via soft tissue failure medial to the medial suture line, with no constru...

Research paper thumbnail of The critical acromial point: the anatomic location of the lateral acromion in the critical shoulder angle

Journal of shoulder and elbow surgery, 2018

Acromioplasty has been proposed as a means of altering elevated critical shoulder angles (CSAs). ... more Acromioplasty has been proposed as a means of altering elevated critical shoulder angles (CSAs). We aimed to localize the critical acromion point (CAP) responsible for the acromial contribution of the CSA and determine whether resection of the CAP can alter the CSA to a normal range. The CAP and 3-dimensional (3D) CSAs were determined on 3D computed tomography reconstructions of 88 cadaveric shoulders and compared with corresponding CSAs on digitally reconstructed radiographs. The position of the CAP was fluoroscopically isolated in 20 of these specimens and the resulting fluoroscopic CSA compared with the corresponding 3D CAP and 3D CSA. We investigated the CSA before and after a virtual acromioplasty of 2.5 and 5 mm at the CAP in specimens with a CSA greater than 35°. The mean CAP was 21% ± 10% of the acromial anterior-posterior length from the anterolateral corner. There was no difference between the mean 3D CSA and the CSA on digitally reconstructed radiographs (32° vs 32°, P = ...

Research paper thumbnail of Regarding "Acute Proximal Anterior Cruciate Ligament Tears: Outcomes After Arthroscopic Suture Anchor Repair Versus Anatomic Single-Bundle Reconstruction

Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association, 2017

Research paper thumbnail of Convergent Validity of the Patient-Reported Outcomes Measurement Information System's Physical Function Computerized Adaptive Test for the Knee and Shoulder Injury Sports Medicine Patient Population

Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association, Jan 10, 2016

To evaluate the convergent validity, precision, and completion times for the Physical Function Co... more To evaluate the convergent validity, precision, and completion times for the Physical Function Computerized Adaptive Test (PF-CAT) in a sports medicine patient population relative to standard measures of knee and shoulder function. We reviewed all patient visits from April through September 2014 with either knee or shoulder complaints from a university-based sports medicine clinic, during which PF-CAT, Single Assessment Numerical Evaluation (SANE), Simple Shoulder Test (SST), and American Shoulder and Elbow Surgeons (ASES) outcome scores for shoulder patients and PF-CAT, SANE, and International Knee Documentation Committee (IKDC) scores for knee patients were obtained, with an initial visit or one follow-up visit included in the study. Spearman correlation was used to evaluate pairwise agreement among scores. The McNemar χ(2) test was used to evaluate a difference in the number of times floor and ceiling values occurred. Wilcoxon signed rank tests were used to compare differences in...

Research paper thumbnail of Meniscal Injury: II. Management

Journal of the American Academy of Orthopaedic Surgeons, 2002

Meniscal repair is a viable alternative to resection in many clinical situations. Repair techniqu... more Meniscal repair is a viable alternative to resection in many clinical situations. Repair techniques traditionally have utilized a variety of suture methods, including inside-out and outside-in techniques. Bioabsorbable implants permit all-inside arthroscopic repairs. The success of meniscal repair depends on appropriate meniscal bed preparation and surgical technique and is also influenced by biologic factors such as tear rim width and associated ligamentous injury. Successful repair in >80% of cases has been reported in conjunction with anterior cruciate ligament reconstruction. Success rates are lower for isolated repairs. Complications related to repair include neurologic injury, postoperative loss of motion, recurrence of the tear, and infection. Meniscal allograft transplantation may provide a treatment option when meniscus salvage is not possible or when a previous total meniscectomy has been done.

Research paper thumbnail of The Medial Stitch in Transosseous-Equivalent Rotator Cuff Repair: Vertical or Horizontal Mattress?

The American Journal of Sports Medicine, 2016

Background: Despite advances in surgical technique, rotator cuff repair retears continue to occur... more Background: Despite advances in surgical technique, rotator cuff repair retears continue to occur at rates of 10%, 22%, and 57% for small, medium, and large tears, respectively. A common mode of failure in transosseous-equivalent rotator cuff repairs is tissue pullout of the medial mattress stitch. While the medial mattress stitch has been studied extensively, no studies have evaluated a vertical mattress pattern placed near the musculotendinous junction in comparison with a horizontal mattress pattern. Hypothesis: Vertical mattress stitches will have higher load to failure and lower gapping compared with horizontal mattress stitches in a transosseous-equivalent rotator cuff repair. Study Design: Controlled laboratory study. Methods: Double-row transosseous-equivalent rotator cuff repairs were performed in 9 pairs of human male cadaveric shoulders (mean age ± SD, 58 ± 10 years). One shoulder in each pair received a medial-row suture pattern using a vertical mattress stitch, and the ...

Research paper thumbnail of Optimizing the Management of Rotator Cuff Problems

American Academy of Orthopaedic Surgeon, 2011

Of the 31 recommendations made by the work group, 19 were determined to be inconclusive because o... more Of the 31 recommendations made by the work group, 19 were determined to be inconclusive because of the absence of definitive evidence. Of the remaining recommendations, four were classified as moderate grade, six as weak, and two as consensus statements of expert opinion. The four moderate-grade recommendations include suggestions that exercise and nonsteroidal antiinflammatory drugs be used to manage rotator cuff symptoms in the absence of a full-thickness tear, that routine acromioplasty is not required at the time of rotator cuff repair, that non-cross-linked, porcine small intestine submucosal xenograft patches not be used to manage rotator cuff tears, and that surgeons can advise patients that workers' compensation status correlates with less favorable outcomes after rotator cuff surgery.

Research paper thumbnail of Medial Patellofemoral Ligament Reconstruction With Semitendinosus Autograft

Arthroscopy Techniques

Patellar instability is a common complaint after traumatic dislocation of the patella. Traumatic ... more Patellar instability is a common complaint after traumatic dislocation of the patella. Traumatic dislocation always leads to tearing of the medial patellofemoral ligament (MPFL). Treatment consists of recovery from the traumatic injury, followed by reconditioning and physical therapy to strengthen the dynamic stabilizers of the patella. In patients with recurrent instability, detailed evaluation of the cause is required to determine the needed interventions. In patients with an incompetent MPFL and recurrent instability, reconstruction is indicated, along with other procedures to address other contributing factors. This article details our technique for MPFL reconstruction using semitendinosus autograft, which can be performed alone or in concert with other realignment procedures.

Research paper thumbnail of An analysis of technical aspects of the arthroscopic Bankart procedure as performed in the United States

Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association, 2014

The purpose of this study was to investigate the intersurgeon variation in technical aspects of p... more The purpose of this study was to investigate the intersurgeon variation in technical aspects of performing an arthroscopic Bankart repair. A unique approach with experienced equipment representatives from 3 different arthroscopic companies was used. Experienced representatives were identified by DePuy Mitek, Smith & Nephew, and Arthrex and filled out questionnaires on how their surgeons performed arthroscopic Bankart procedures. This was performed in a blinded fashion with no knowledge of the identities of the specific surgeons or representatives by us. A video on different aspects of the procedure was observed by each representative before filling out the questionnaire to help standardize responses. Data were collected using REDCap (Research Electronic Data Capture). Data were analyzed as an infrequent observation with 0% to 30% of representatives reporting the observation; sometimes, 31% to 70% reporting the observation; and often, greater than 70% of representatives reporting. Se...

Research paper thumbnail of Use of knee magnetic resonance imaging by primary care physicians in patients aged 40 years and older

Sports health, 2010

Criteria are needed for primary care providers such that they can evaluate age-related knee pain ... more Criteria are needed for primary care providers such that they can evaluate age-related knee pain in a cost-effective manner. This study examined (1) in what percentage of patients are appropriate radiographic views of the knee ordered before magnetic resonance imaging (MRI) for knee pain, (2) specialists' retrospective evaluation for appropriate utilization of MRI in knee pain, and (3) in what manner would the MRIs have altered diagnosis and management of knee disorders. Primary care providers underuse appropriate radiographs-especially, flexion weightbearing posteroanterior films-and overuse MRIs when evaluating older patients with knee pain. Case control. The authors performed a retrospective analysis of 100 patients older than 40 years with knee MRIs. Patient encounters with primary care physicians were reviewed. Given available information, specialists then formulated a pre- and post-MRI diagnosis and treatment plan and indicated whether the MRI would have altered their trea...

Research paper thumbnail of Arthroscopic management of shoulder instabilities: anterior, posterior, and multidirectional

Instructional course lectures, 2010

Arthroscopy is considered a relatively new technique for the surgical repair of an unstable shoul... more Arthroscopy is considered a relatively new technique for the surgical repair of an unstable shoulder. Shoulder arthroscopy has grown in popularity and is considered the gold standard for treating carefully selected patients. Despite its increasing popularity, the procedure has a significant learning curve and has resulted in early higher recurrence rates when compared with patients treated with open techniques. With the addition of newer instrumentation, the refinement of techniques, and additional capsular plication and tensioning, outcomes for patients treated with shoulder arthroscopy should continue to improve. A major distinguishing feature in selecting appropriate candidates for shoulder arthroscopy is whether there have been significant bone changes resulting from dislocation recurrence. Recurrent anterior dislocation may create an anterior glenoid rim fracture, erosion loss from multiple recurrences, and an impression defect on the posterior aspect of the humeral head. The l...

Research paper thumbnail of A Biomechanical Comparison of Reverse Total Shoulder Arthroplasty Systems

Introduction:Given that factors like center of rotation (COR), neck shaft angle, glenosphere diam... more Introduction:Given that factors like center of rotation (COR), neck shaft angle, glenosphere diameter and component tilt alter the biomechanics of reverse total shoulder arthroplasty (rTSA), the pe...

Research paper thumbnail of Comparison of Methods to Predict Scapular Notching From Radiographs After Reverse Total Shoulder Arthroplasty

ASME 2012 Summer Bioengineering Conference, Parts A and B, 2012

Scapular notching is a complication of reverse total shoulder arthroplasty (rTSA) that results in... more Scapular notching is a complication of reverse total shoulder arthroplasty (rTSA) that results in bone loss on the lateral border of the scapula. Notching has been reported in up to 86% of patients at 5 year follow-up [1], and is graded 1–4 as a function of progressive bone loss [2]. Notching may arise from impingement, erosion, periprosthetic osteolysis, stress shielding or a combination of these [1]. Glenosphere position can mitigate notching by limiting hardware impingement [3–5], but may increase the forces required to abduct the arm [6]. Clinicians might optimize patient range of motion and function via implant placement if susceptibility to notching was known a-priori.

Research paper thumbnail of Biomechanical comparison of reverse total shoulder arthroplasty systems in soft tissue–constrained shoulders

Journal of Shoulder and Elbow Surgery, 2014

Background: Numerous studies have examined the biomechanics of isolated variables in reverse tota... more Background: Numerous studies have examined the biomechanics of isolated variables in reverse total shoulder arthroplasty. This study directly compared the composite performance of two reverse total shoulder arthroplasty systems; each system was designed around either a medialized or a lateralized glenohumeral center of rotation. Methods: Seven pairs of shoulders were tested on a biomechanical simulator. Center of rotation, position of the humerus, passive and active range of motion, and force to abduct the arm were quantified. Native arms were tested, implanted with a Tornier Aequalis or DJO Surgical Reverse Shoulder Prosthesis (RSP), and then retested. Differences from the native state were then documented. Results: Both systems shifted the center of rotation medially and inferiorly relative to native. Medial shifts were greater in the Aequalis implant (P < .037). All humeri shifted inferior compared with native but moved medially with the Aequalis (P < .001). Peak passive abduction, internal rotation, and external rotation did not differ between systems (P > .05). Both reverse total shoulder arthroplasty systems exhibited adduction deficits, but the RSP implant deficit was smaller (P ¼ .046 between implants). Both systems reduced forces to abduct the arm compared with native, although the Aequalis required more force to initiate motion from the resting position (P ¼ .022). Conclusion: Given the differences in system designs and configurations, outcome variables were generally comparable. The RSP implant allowed slightly more adduction, had a more lateralized humeral position, and required less force to initiate elevation. These factors may play roles in limiting scapular notching, improving active external rotation by normalizing the residual rotator cuff length, and limiting excessive stress on the deltoid.

Research paper thumbnail of Indwelling interscalene catheter use in an outpatient setting for shoulder surgery: Technique, efficacy, and complications

Journal of Shoulder and Elbow Surgery, 2007

Indwelling interscalene catheters are utilized for inpatient postoperative pain control after sho... more Indwelling interscalene catheters are utilized for inpatient postoperative pain control after shoulder surgery. Improved medical equipment and advanced techniques may allow safe and efficacious outpatient use. One hundred and forty-four consecutive indwelling interscalene catheter placements were reviewed to determine adverse events, complications, and efficacy. Real-time ultrasound-guided catheter placement technique is described. Post-anesthesia care unit (PACU) narcotic consumption and last recorded pain score were reviewed to gauge efficacy. The catheter placement technique was 98% successful. There were 14 (9.7%) minor adverse events including inadequate analgesia (8), accidental catheter removal (4) of disconnection (1), and shortness of breath (1). The single complication (0.7%) was a small apical pneumothorax. The average PACU narcotic consumption in intravenous morphine equivalents was 1.7 mg. The average last recorded PACU pain score on a scale of 1 to 10 was 0.6. Catheter placement under real-time ultrasound guidance is accurate. Outpatient use of indwelling interscalene catheters is safe and efficacious.

Research paper thumbnail of Interscalene block for postoperative analgesia using only ultrasound guidance: the outcome in 200 patients

Journal of Clinical Anesthesia, 2009

Study Objective: To report the results of single and continuous interscalene blocks (ISB) perform... more Study Objective: To report the results of single and continuous interscalene blocks (ISB) performed using ultrasound (US) guidance only. Design: Prospective, observational study. Setting: Operating room of a university-affiliated orthopaedic hospital. Patients: 200 ASA physical status I, II, and III patients undergoing shoulder or elbow surgery. Interventions: Single or continuous ISB were placed using US guidance only. All blocks were performed by anesthesiology residents and supervised by faculty anesthesiologists. Measurements: Success rate and frequency of untoward events such as needle paresthesia, vessel puncture, infection, and persistent neurologic deficits were prospectively recorded. Main Results: 99% of patients reported sensory and motor changes in the distribution of the brachial plexus and postoperative pain scores ≤ 2. The rates of needle paresthesia and vessel puncture were 6% and 1%, respectively. Two patients (1%) reported transient neurologic deficits. No signs or symptoms of infection or intravascular injection were noted. There were also no permanent neurologic deficits. Conclusions: In this group of 200 consecutive patients, the success rate for postoperative analgesia using US guidance only was 99%. Untoward events such as needle paresthesia and persistent neurologic deficits were lower than existing data on nerve stimulation and paresthesia techniques. Ultrasound can be successfully used as a "stand alone" method to perform ISB.

Research paper thumbnail of Outpatient Management of Continuous Peripheral Nerve Catheters Placed Using Ultrasound Guidance: An Experience in 620 Patients

Anesthesia & Analgesia, 2006

Continuous peripheral nerve block (CPNB) is an optimal choice for analgesia after orthopedic proc... more Continuous peripheral nerve block (CPNB) is an optimal choice for analgesia after orthopedic procedures, but is not commonly used in outpatients because of concern regarding the possibility of catheter-related complications. In addition, it may be difficult to provide adequate patient access to physicians in this setting. We present 620 outpatients who were treated with CPNB using an established protocol. All catheters were placed using direct ultrasound visualization. These patients received extensive oral and written preoperative instruction and were provided continuous telephone access to the anesthesiologist during the postoperative period. All patients were also contacted at home by telephone on the first postoperative day. In addition, each patient was seen and examined by the surgeon within 2 wk of hospital discharge. Of the 620 patients, there were 190 interscalene (brachial plexus), 206 fascia iliaca (femoral nerve), and 224 popliteal fossa (sciatic nerve) catheters. Two patients (0.3%) had complications related to the nerve block. In both of these patients, the symptoms resolved within 6 wk of surgery. Twenty-six patients (4.2%) required postoperative interventions by the anesthesiologist. One patient returned to the hospital for catheter removal. In this large series of outpatients treated with CPNB, there were surprisingly few interventions requiring an anesthesiologist. Likewise, patients were able to manage and remove their catheters at home without additional follow-up. This suggests that with adequate instruction and telephone access to health care providers, patients are comfortable with managing and removing CPNB catheters at home.

Research paper thumbnail of Rotator Cuff Repair Technique With Transosseous Knotless Anchor System

Arthroscopy techniques, 2018

Various surgical techniques exist for rotator cuff repair that provide a suitable environment for... more Various surgical techniques exist for rotator cuff repair that provide a suitable environment for tendon-bone healing. Arthroscopic recreation of transosseous repairs, which had previously been performed by open or miniopen techniques, can now be performed; however, arthroscopic, transosseous passage of suture material can be challenging technically. There are potential biologic and cost-saving advantages of arthroscopic transosseous rotator cuff repair that make an efficient and reproducible technique desirable for arthroscopists. The technique for arthroscopic transosseous rotator cuff repair using a knotless anchor-based system is demonstrated in the current Technical Note. Potential advantages of this construct include excellent biomechanics, enhanced footprint vascularization, and utility in poor bone quality while using minimal anchor numbers. Further studies will be needed to elucidate healing rates and clinical outcomes.

Research paper thumbnail of A Prospective Randomized Clinical Trial Comparing Arthroscopic Single-and Double-Row Rotator Cuff Repair

American Journal of Sports Medicine, 2009

Arthroscopic rotator cuff repair is becoming increasingly popular with a significant amount of re... more Arthroscopic rotator cuff repair is becoming increasingly popular with a significant amount of research being performed evaluating techniques and outcomes. Most studies have used a single row of anchors for attaching the rotator cuff tendon to bone when doing the repair. With the recent emphasis on anatomy of the rotator cuff footprint, techniques attaching the rotator cuff tendon over more of its normal footprint have gained popularity. § In vitro studies have analyzed repair techniques using various combinations

Research paper thumbnail of Patient- and Procedure-Specific Variables Driving Total Direct Costs of Outpatient Anterior Cruciate Ligament Reconstruction

Orthopaedic journal of sports medicine, 2018

Few studies have investigated the influence of patient-specific variables or procedure-specific f... more Few studies have investigated the influence of patient-specific variables or procedure-specific factors on the overall cost of anterior cruciate ligament reconstruction (ACLR) in an ambulatory surgery setting. To determine patient- and procedure-specific factors influencing the overall direct cost of outpatient arthroscopic ACLR utilizing a unique value-driven outcomes (VDO) tool. Cohort study (economic and decision analysis); Level of evidence, 3. All ACLRs performed by 4 surgeons over 2 years were retrospectively reviewed. Cost data were derived from the VDO tool. Patient-specific variables included age, body mass index, comorbidities, American Society of Anesthesiologists (ASA) classification, smoking status, preoperative Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function Computerized Adaptive Testing (PF-CAT) score, and preoperative Single Assessment Numeric Evaluation (SANE) score. Procedure-specific variables included graft type, revision statu...

Research paper thumbnail of Biomechanical Comparison of Transosseous Knotless Rotator Cuff Repair Versus Transosseous Equivalent Repair: Half The Anchors With Equivalent Biomechanics?

Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association, 2018

To compare the biomechanics of a transosseous equivalent (TOE) repair using medial and lateral an... more To compare the biomechanics of a transosseous equivalent (TOE) repair using medial and lateral anchors with tape to a transosseous knotless (TOK) tape repair with only laterally placed intraosseous anchors. One of 2 different repairs were performed on 8 paired specimens: (1) transosseous equivalent (TOE) tape repair or (2) transosseous knotless (TOK) tape repair. Specimens were mounted on a materials testing machine and loaded in uniaxial tension to measure cyclic construct gap formation, followed by failure testing. Paired t tests were used to compare gapping, ultimate stiffness, and failure loads. Fisher exact test was used to compare modes of failure (soft tissue failure vs construct failure). Peak cyclic gapping, failure stiffness, and ultimate failure loads did not differ between TOE and TOK repairs (P = .140 for gapping, P = .106 for stiffness, and P = .672 for peak failure loads). All TOK repairs failed via soft tissue failure medial to the medial suture line, with no constru...

Research paper thumbnail of The critical acromial point: the anatomic location of the lateral acromion in the critical shoulder angle

Journal of shoulder and elbow surgery, 2018

Acromioplasty has been proposed as a means of altering elevated critical shoulder angles (CSAs). ... more Acromioplasty has been proposed as a means of altering elevated critical shoulder angles (CSAs). We aimed to localize the critical acromion point (CAP) responsible for the acromial contribution of the CSA and determine whether resection of the CAP can alter the CSA to a normal range. The CAP and 3-dimensional (3D) CSAs were determined on 3D computed tomography reconstructions of 88 cadaveric shoulders and compared with corresponding CSAs on digitally reconstructed radiographs. The position of the CAP was fluoroscopically isolated in 20 of these specimens and the resulting fluoroscopic CSA compared with the corresponding 3D CAP and 3D CSA. We investigated the CSA before and after a virtual acromioplasty of 2.5 and 5 mm at the CAP in specimens with a CSA greater than 35°. The mean CAP was 21% ± 10% of the acromial anterior-posterior length from the anterolateral corner. There was no difference between the mean 3D CSA and the CSA on digitally reconstructed radiographs (32° vs 32°, P = ...

Research paper thumbnail of Regarding "Acute Proximal Anterior Cruciate Ligament Tears: Outcomes After Arthroscopic Suture Anchor Repair Versus Anatomic Single-Bundle Reconstruction

Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association, 2017

Research paper thumbnail of Convergent Validity of the Patient-Reported Outcomes Measurement Information System's Physical Function Computerized Adaptive Test for the Knee and Shoulder Injury Sports Medicine Patient Population

Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association, Jan 10, 2016

To evaluate the convergent validity, precision, and completion times for the Physical Function Co... more To evaluate the convergent validity, precision, and completion times for the Physical Function Computerized Adaptive Test (PF-CAT) in a sports medicine patient population relative to standard measures of knee and shoulder function. We reviewed all patient visits from April through September 2014 with either knee or shoulder complaints from a university-based sports medicine clinic, during which PF-CAT, Single Assessment Numerical Evaluation (SANE), Simple Shoulder Test (SST), and American Shoulder and Elbow Surgeons (ASES) outcome scores for shoulder patients and PF-CAT, SANE, and International Knee Documentation Committee (IKDC) scores for knee patients were obtained, with an initial visit or one follow-up visit included in the study. Spearman correlation was used to evaluate pairwise agreement among scores. The McNemar χ(2) test was used to evaluate a difference in the number of times floor and ceiling values occurred. Wilcoxon signed rank tests were used to compare differences in...

Research paper thumbnail of Meniscal Injury: II. Management

Journal of the American Academy of Orthopaedic Surgeons, 2002

Meniscal repair is a viable alternative to resection in many clinical situations. Repair techniqu... more Meniscal repair is a viable alternative to resection in many clinical situations. Repair techniques traditionally have utilized a variety of suture methods, including inside-out and outside-in techniques. Bioabsorbable implants permit all-inside arthroscopic repairs. The success of meniscal repair depends on appropriate meniscal bed preparation and surgical technique and is also influenced by biologic factors such as tear rim width and associated ligamentous injury. Successful repair in >80% of cases has been reported in conjunction with anterior cruciate ligament reconstruction. Success rates are lower for isolated repairs. Complications related to repair include neurologic injury, postoperative loss of motion, recurrence of the tear, and infection. Meniscal allograft transplantation may provide a treatment option when meniscus salvage is not possible or when a previous total meniscectomy has been done.

Research paper thumbnail of The Medial Stitch in Transosseous-Equivalent Rotator Cuff Repair: Vertical or Horizontal Mattress?

The American Journal of Sports Medicine, 2016

Background: Despite advances in surgical technique, rotator cuff repair retears continue to occur... more Background: Despite advances in surgical technique, rotator cuff repair retears continue to occur at rates of 10%, 22%, and 57% for small, medium, and large tears, respectively. A common mode of failure in transosseous-equivalent rotator cuff repairs is tissue pullout of the medial mattress stitch. While the medial mattress stitch has been studied extensively, no studies have evaluated a vertical mattress pattern placed near the musculotendinous junction in comparison with a horizontal mattress pattern. Hypothesis: Vertical mattress stitches will have higher load to failure and lower gapping compared with horizontal mattress stitches in a transosseous-equivalent rotator cuff repair. Study Design: Controlled laboratory study. Methods: Double-row transosseous-equivalent rotator cuff repairs were performed in 9 pairs of human male cadaveric shoulders (mean age ± SD, 58 ± 10 years). One shoulder in each pair received a medial-row suture pattern using a vertical mattress stitch, and the ...

Research paper thumbnail of Optimizing the Management of Rotator Cuff Problems

American Academy of Orthopaedic Surgeon, 2011

Of the 31 recommendations made by the work group, 19 were determined to be inconclusive because o... more Of the 31 recommendations made by the work group, 19 were determined to be inconclusive because of the absence of definitive evidence. Of the remaining recommendations, four were classified as moderate grade, six as weak, and two as consensus statements of expert opinion. The four moderate-grade recommendations include suggestions that exercise and nonsteroidal antiinflammatory drugs be used to manage rotator cuff symptoms in the absence of a full-thickness tear, that routine acromioplasty is not required at the time of rotator cuff repair, that non-cross-linked, porcine small intestine submucosal xenograft patches not be used to manage rotator cuff tears, and that surgeons can advise patients that workers' compensation status correlates with less favorable outcomes after rotator cuff surgery.

Research paper thumbnail of Medial Patellofemoral Ligament Reconstruction With Semitendinosus Autograft

Arthroscopy Techniques

Patellar instability is a common complaint after traumatic dislocation of the patella. Traumatic ... more Patellar instability is a common complaint after traumatic dislocation of the patella. Traumatic dislocation always leads to tearing of the medial patellofemoral ligament (MPFL). Treatment consists of recovery from the traumatic injury, followed by reconditioning and physical therapy to strengthen the dynamic stabilizers of the patella. In patients with recurrent instability, detailed evaluation of the cause is required to determine the needed interventions. In patients with an incompetent MPFL and recurrent instability, reconstruction is indicated, along with other procedures to address other contributing factors. This article details our technique for MPFL reconstruction using semitendinosus autograft, which can be performed alone or in concert with other realignment procedures.

Research paper thumbnail of An analysis of technical aspects of the arthroscopic Bankart procedure as performed in the United States

Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association, 2014

The purpose of this study was to investigate the intersurgeon variation in technical aspects of p... more The purpose of this study was to investigate the intersurgeon variation in technical aspects of performing an arthroscopic Bankart repair. A unique approach with experienced equipment representatives from 3 different arthroscopic companies was used. Experienced representatives were identified by DePuy Mitek, Smith & Nephew, and Arthrex and filled out questionnaires on how their surgeons performed arthroscopic Bankart procedures. This was performed in a blinded fashion with no knowledge of the identities of the specific surgeons or representatives by us. A video on different aspects of the procedure was observed by each representative before filling out the questionnaire to help standardize responses. Data were collected using REDCap (Research Electronic Data Capture). Data were analyzed as an infrequent observation with 0% to 30% of representatives reporting the observation; sometimes, 31% to 70% reporting the observation; and often, greater than 70% of representatives reporting. Se...

Research paper thumbnail of Use of knee magnetic resonance imaging by primary care physicians in patients aged 40 years and older

Sports health, 2010

Criteria are needed for primary care providers such that they can evaluate age-related knee pain ... more Criteria are needed for primary care providers such that they can evaluate age-related knee pain in a cost-effective manner. This study examined (1) in what percentage of patients are appropriate radiographic views of the knee ordered before magnetic resonance imaging (MRI) for knee pain, (2) specialists' retrospective evaluation for appropriate utilization of MRI in knee pain, and (3) in what manner would the MRIs have altered diagnosis and management of knee disorders. Primary care providers underuse appropriate radiographs-especially, flexion weightbearing posteroanterior films-and overuse MRIs when evaluating older patients with knee pain. Case control. The authors performed a retrospective analysis of 100 patients older than 40 years with knee MRIs. Patient encounters with primary care physicians were reviewed. Given available information, specialists then formulated a pre- and post-MRI diagnosis and treatment plan and indicated whether the MRI would have altered their trea...

Research paper thumbnail of Arthroscopic management of shoulder instabilities: anterior, posterior, and multidirectional

Instructional course lectures, 2010

Arthroscopy is considered a relatively new technique for the surgical repair of an unstable shoul... more Arthroscopy is considered a relatively new technique for the surgical repair of an unstable shoulder. Shoulder arthroscopy has grown in popularity and is considered the gold standard for treating carefully selected patients. Despite its increasing popularity, the procedure has a significant learning curve and has resulted in early higher recurrence rates when compared with patients treated with open techniques. With the addition of newer instrumentation, the refinement of techniques, and additional capsular plication and tensioning, outcomes for patients treated with shoulder arthroscopy should continue to improve. A major distinguishing feature in selecting appropriate candidates for shoulder arthroscopy is whether there have been significant bone changes resulting from dislocation recurrence. Recurrent anterior dislocation may create an anterior glenoid rim fracture, erosion loss from multiple recurrences, and an impression defect on the posterior aspect of the humeral head. The l...

Research paper thumbnail of A Biomechanical Comparison of Reverse Total Shoulder Arthroplasty Systems

Introduction:Given that factors like center of rotation (COR), neck shaft angle, glenosphere diam... more Introduction:Given that factors like center of rotation (COR), neck shaft angle, glenosphere diameter and component tilt alter the biomechanics of reverse total shoulder arthroplasty (rTSA), the pe...

Research paper thumbnail of Comparison of Methods to Predict Scapular Notching From Radiographs After Reverse Total Shoulder Arthroplasty

ASME 2012 Summer Bioengineering Conference, Parts A and B, 2012

Scapular notching is a complication of reverse total shoulder arthroplasty (rTSA) that results in... more Scapular notching is a complication of reverse total shoulder arthroplasty (rTSA) that results in bone loss on the lateral border of the scapula. Notching has been reported in up to 86% of patients at 5 year follow-up [1], and is graded 1–4 as a function of progressive bone loss [2]. Notching may arise from impingement, erosion, periprosthetic osteolysis, stress shielding or a combination of these [1]. Glenosphere position can mitigate notching by limiting hardware impingement [3–5], but may increase the forces required to abduct the arm [6]. Clinicians might optimize patient range of motion and function via implant placement if susceptibility to notching was known a-priori.

Research paper thumbnail of Biomechanical comparison of reverse total shoulder arthroplasty systems in soft tissue–constrained shoulders

Journal of Shoulder and Elbow Surgery, 2014

Background: Numerous studies have examined the biomechanics of isolated variables in reverse tota... more Background: Numerous studies have examined the biomechanics of isolated variables in reverse total shoulder arthroplasty. This study directly compared the composite performance of two reverse total shoulder arthroplasty systems; each system was designed around either a medialized or a lateralized glenohumeral center of rotation. Methods: Seven pairs of shoulders were tested on a biomechanical simulator. Center of rotation, position of the humerus, passive and active range of motion, and force to abduct the arm were quantified. Native arms were tested, implanted with a Tornier Aequalis or DJO Surgical Reverse Shoulder Prosthesis (RSP), and then retested. Differences from the native state were then documented. Results: Both systems shifted the center of rotation medially and inferiorly relative to native. Medial shifts were greater in the Aequalis implant (P < .037). All humeri shifted inferior compared with native but moved medially with the Aequalis (P < .001). Peak passive abduction, internal rotation, and external rotation did not differ between systems (P > .05). Both reverse total shoulder arthroplasty systems exhibited adduction deficits, but the RSP implant deficit was smaller (P ¼ .046 between implants). Both systems reduced forces to abduct the arm compared with native, although the Aequalis required more force to initiate motion from the resting position (P ¼ .022). Conclusion: Given the differences in system designs and configurations, outcome variables were generally comparable. The RSP implant allowed slightly more adduction, had a more lateralized humeral position, and required less force to initiate elevation. These factors may play roles in limiting scapular notching, improving active external rotation by normalizing the residual rotator cuff length, and limiting excessive stress on the deltoid.

Research paper thumbnail of Indwelling interscalene catheter use in an outpatient setting for shoulder surgery: Technique, efficacy, and complications

Journal of Shoulder and Elbow Surgery, 2007

Indwelling interscalene catheters are utilized for inpatient postoperative pain control after sho... more Indwelling interscalene catheters are utilized for inpatient postoperative pain control after shoulder surgery. Improved medical equipment and advanced techniques may allow safe and efficacious outpatient use. One hundred and forty-four consecutive indwelling interscalene catheter placements were reviewed to determine adverse events, complications, and efficacy. Real-time ultrasound-guided catheter placement technique is described. Post-anesthesia care unit (PACU) narcotic consumption and last recorded pain score were reviewed to gauge efficacy. The catheter placement technique was 98% successful. There were 14 (9.7%) minor adverse events including inadequate analgesia (8), accidental catheter removal (4) of disconnection (1), and shortness of breath (1). The single complication (0.7%) was a small apical pneumothorax. The average PACU narcotic consumption in intravenous morphine equivalents was 1.7 mg. The average last recorded PACU pain score on a scale of 1 to 10 was 0.6. Catheter placement under real-time ultrasound guidance is accurate. Outpatient use of indwelling interscalene catheters is safe and efficacious.

Research paper thumbnail of Interscalene block for postoperative analgesia using only ultrasound guidance: the outcome in 200 patients

Journal of Clinical Anesthesia, 2009

Study Objective: To report the results of single and continuous interscalene blocks (ISB) perform... more Study Objective: To report the results of single and continuous interscalene blocks (ISB) performed using ultrasound (US) guidance only. Design: Prospective, observational study. Setting: Operating room of a university-affiliated orthopaedic hospital. Patients: 200 ASA physical status I, II, and III patients undergoing shoulder or elbow surgery. Interventions: Single or continuous ISB were placed using US guidance only. All blocks were performed by anesthesiology residents and supervised by faculty anesthesiologists. Measurements: Success rate and frequency of untoward events such as needle paresthesia, vessel puncture, infection, and persistent neurologic deficits were prospectively recorded. Main Results: 99% of patients reported sensory and motor changes in the distribution of the brachial plexus and postoperative pain scores ≤ 2. The rates of needle paresthesia and vessel puncture were 6% and 1%, respectively. Two patients (1%) reported transient neurologic deficits. No signs or symptoms of infection or intravascular injection were noted. There were also no permanent neurologic deficits. Conclusions: In this group of 200 consecutive patients, the success rate for postoperative analgesia using US guidance only was 99%. Untoward events such as needle paresthesia and persistent neurologic deficits were lower than existing data on nerve stimulation and paresthesia techniques. Ultrasound can be successfully used as a "stand alone" method to perform ISB.

Research paper thumbnail of Outpatient Management of Continuous Peripheral Nerve Catheters Placed Using Ultrasound Guidance: An Experience in 620 Patients

Anesthesia & Analgesia, 2006

Continuous peripheral nerve block (CPNB) is an optimal choice for analgesia after orthopedic proc... more Continuous peripheral nerve block (CPNB) is an optimal choice for analgesia after orthopedic procedures, but is not commonly used in outpatients because of concern regarding the possibility of catheter-related complications. In addition, it may be difficult to provide adequate patient access to physicians in this setting. We present 620 outpatients who were treated with CPNB using an established protocol. All catheters were placed using direct ultrasound visualization. These patients received extensive oral and written preoperative instruction and were provided continuous telephone access to the anesthesiologist during the postoperative period. All patients were also contacted at home by telephone on the first postoperative day. In addition, each patient was seen and examined by the surgeon within 2 wk of hospital discharge. Of the 620 patients, there were 190 interscalene (brachial plexus), 206 fascia iliaca (femoral nerve), and 224 popliteal fossa (sciatic nerve) catheters. Two patients (0.3%) had complications related to the nerve block. In both of these patients, the symptoms resolved within 6 wk of surgery. Twenty-six patients (4.2%) required postoperative interventions by the anesthesiologist. One patient returned to the hospital for catheter removal. In this large series of outpatients treated with CPNB, there were surprisingly few interventions requiring an anesthesiologist. Likewise, patients were able to manage and remove their catheters at home without additional follow-up. This suggests that with adequate instruction and telephone access to health care providers, patients are comfortable with managing and removing CPNB catheters at home.

Research paper thumbnail of Rotator Cuff Repair Technique With Transosseous Knotless Anchor System

Arthroscopy techniques, 2018

Various surgical techniques exist for rotator cuff repair that provide a suitable environment for... more Various surgical techniques exist for rotator cuff repair that provide a suitable environment for tendon-bone healing. Arthroscopic recreation of transosseous repairs, which had previously been performed by open or miniopen techniques, can now be performed; however, arthroscopic, transosseous passage of suture material can be challenging technically. There are potential biologic and cost-saving advantages of arthroscopic transosseous rotator cuff repair that make an efficient and reproducible technique desirable for arthroscopists. The technique for arthroscopic transosseous rotator cuff repair using a knotless anchor-based system is demonstrated in the current Technical Note. Potential advantages of this construct include excellent biomechanics, enhanced footprint vascularization, and utility in poor bone quality while using minimal anchor numbers. Further studies will be needed to elucidate healing rates and clinical outcomes.