Papers by Truong Giang Nguyen
Vehicle System Dynamics, 2007
... CHO-CHUNG LIANG*, CHI-FENG CHIANG and TRUONG-GIANG NGUYEN Department of Mechanical and Automa... more ... CHO-CHUNG LIANG*, CHI-FENG CHIANG and TRUONG-GIANG NGUYEN Department of Mechanical and Automation Engineering, Da-Yeh University, 112 Shan-Jiau Rd., Da-Tsuen, Changhua, Taiwan 515, Republic of China ...
Optics Express, 2012
A Faraday Effect sensor with Nd(2)Fe(14)B biasing magnetic film was described. Ta/Nd(2)Fe(14)B/Ta... more A Faraday Effect sensor with Nd(2)Fe(14)B biasing magnetic film was described. Ta/Nd(2)Fe(14)B/Ta films were grown by magnetron sputtering method. The magnetic domain in the sensor with the Nd(2)Fe(14)B biasing magnetic film can persist its distribution. The average linearity error of Faraday Effect sensor with biasing magnetic film decreased from 1.42% to 0.125% compared with non-biasing magnetic film, and the measurement range increased from 820 Oe to 900 Oe.
Optics Express, 2014
Stokes polarimeters are most commonly used to measure the state of polarization of optical wave. ... more Stokes polarimeters are most commonly used to measure the state of polarization of optical wave. Dependence of Stokes parameters, degree of polarization on external magnetic field are presented for garnet and groove films on garnet in the transmission and reflection modes. The Stokes parameters S 1 , S 2 , S 3 of different modes show different tendency and asymmetrically change when the external magnetic field change, while the degree of polarization basically unchange.
Intelligent Automation & Soft Computing, 2011
Intelligent Automation & Soft Computing, 2010
Control Engineering Practice, 2010
In this study, an open programmable logic controller (PLC) from Fuji electric prescribed in the S... more In this study, an open programmable logic controller (PLC) from Fuji electric prescribed in the Structured Text program was applied to develop a look-ahead linear jerk filter (LALJF) for a computerized numerically controlled (CNC) machine. To ensure the smooth and accurate motion of a tool with a linear change in jerk during real-time machining, the proposed filter was formed by combining a look-ahead algorithm with three modified moving average filters (3MMAF). The lookahead algorithm performed a single look-ahead step-change in the speed of the speed curve. Based on a step-changing speed profile, given maximal acceleration/deceleration and maximum jerk, the speed curve was modified before it was passed through a linear jerk filter to reduce machining time. The speed commands filtered by the proposed filter stabilize machine table at the beginning and end of its motion, and at any point at which its speed exhibits a step-change. The theoretical and computational aspects of the LALJF are presented together with experimental results of its implementation on an X-Y table. The multiple-step-changing speed curve of a CNC machine and the speed curve of a high-speed measurement system were constructed in order to verify the feasibility and precision of the proposed method.
Vehicle System Dynamics, 2007
... CHO-CHUNG LIANG*, CHI-FENG CHIANG and TRUONG-GIANG NGUYEN Department of Mechanical and Automa... more ... CHO-CHUNG LIANG*, CHI-FENG CHIANG and TRUONG-GIANG NGUYEN Department of Mechanical and Automation Engineering, Da-Yeh University, 112 Shan-Jiau Rd., Da-Tsuen, Changhua, Taiwan 515, Republic of China ...
Optics Express, 2012
A Faraday Effect sensor with Nd(2)Fe(14)B biasing magnetic film was described. Ta/Nd(2)Fe(14)B/Ta... more A Faraday Effect sensor with Nd(2)Fe(14)B biasing magnetic film was described. Ta/Nd(2)Fe(14)B/Ta films were grown by magnetron sputtering method. The magnetic domain in the sensor with the Nd(2)Fe(14)B biasing magnetic film can persist its distribution. The average linearity error of Faraday Effect sensor with biasing magnetic film decreased from 1.42% to 0.125% compared with non-biasing magnetic film, and the measurement range increased from 820 Oe to 900 Oe.
Optics Express, 2014
Stokes polarimeters are most commonly used to measure the state of polarization of optical wave. ... more Stokes polarimeters are most commonly used to measure the state of polarization of optical wave. Dependence of Stokes parameters, degree of polarization on external magnetic field are presented for garnet and groove films on garnet in the transmission and reflection modes. The Stokes parameters S 1 , S 2 , S 3 of different modes show different tendency and asymmetrically change when the external magnetic field change, while the degree of polarization basically unchange.
Intelligent Automation & Soft Computing, 2011
Intelligent Automation & Soft Computing, 2010
Control Engineering Practice, 2010
In this study, an open programmable logic controller (PLC) from Fuji electric prescribed in the S... more In this study, an open programmable logic controller (PLC) from Fuji electric prescribed in the Structured Text program was applied to develop a look-ahead linear jerk filter (LALJF) for a computerized numerically controlled (CNC) machine. To ensure the smooth and accurate motion of a tool with a linear change in jerk during real-time machining, the proposed filter was formed by combining a look-ahead algorithm with three modified moving average filters (3MMAF). The lookahead algorithm performed a single look-ahead step-change in the speed of the speed curve. Based on a step-changing speed profile, given maximal acceleration/deceleration and maximum jerk, the speed curve was modified before it was passed through a linear jerk filter to reduce machining time. The speed commands filtered by the proposed filter stabilize machine table at the beginning and end of its motion, and at any point at which its speed exhibits a step-change. The theoretical and computational aspects of the LALJF are presented together with experimental results of its implementation on an X-Y table. The multiple-step-changing speed curve of a CNC machine and the speed curve of a high-speed measurement system were constructed in order to verify the feasibility and precision of the proposed method.