Biomechanical Assessment of Bicuspid Aortic Valve Phenotypes: A Fluid–Structure Interaction Modelling Approach (original) (raw)

Clinical implications of the biomechanics of bicuspid aortic valve and bicuspid aortopathy

Frontiers in Cardiovascular Medicine

Bicuspid aortic valve (BAV), which affects up to 2% of the general population, results from the abnormal fusion of the cusps of the aortic valve. Patients with BAV are at a higher risk for developing aortic dilatation, a condition known as bicuspid aortopathy, which is associated with potentially life-threatening sequelae such as aortic dissection and aortic rupture. Although BAV biomechanics have been shown to contribute to aortopathy, their precise impact is yet to be delineated. Herein, we present the latest literature related to BAV biomechanics. We present the most recent definitions and classifications for BAV. We also summarize the current evidence pertaining to the mechanisms that drive bicuspid aortopathy. We highlight how aberrant flow patterns can contribute to the development of aortic dilatation. Finally, we discuss the role cardiac magnetic resonance imaging can have in assessing and managing patient with BAV and bicuspid aortopathy.

Biomechanical properties and histomorphometric features of aortic tissue in patients with or without bicuspid aortic valve

Journal of Thoracic Disease

Background: We sought to investigate and compare biomechanical properties and histomorphometric findings of thoracic ascending aorta aneurysm (TAA) tissue from patients with bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV) in order to clarify mechanisms underlying differences in the clinical course. Methods: Circumferential sections of TAA tissue in patients with BAV (BAV-TAA) and TAV (TAV-TAA) were obtained during surgery and used for biomechanical tests and histomorphometrical analysis. Results: In BAV-TAA, we observed biomechanical higher peak stress and lower Young modulus values compared with TAV-TAA wall. The right lateral longitudinal region seemed to be the most fragile zone of the TAA wall. Mechanical stress-induced rupture of BAV-TAA tissue was sudden and uniform in all aortic wall layers, whereas a gradual and progressive aortic wall breakage was described in TAV-TAA. Histomorphometric analysis revealed higher amount of collagen but not elastin in BAV-TAA tunica media. Conclusions: The higher deformability of BAV-TAA tissue supports the hypothesis that increased wall shear stress doesn't explain the increased risk of sudden onset of rupture and dissection; other mechanisms, likely related to alteration of specific genetic pathways and epigenetic signals, could be investigated to explain differences in aortic dissection and rupture in BAV patients.

Computational Analysis of Wall Shear Stress Patterns on Calcified and Bicuspid Aortic Valves: Focus on Radial and Coaptation Patterns

Fluids

Calcification and bicuspid valve formation are important aortic valve disorders that disturb the hemodynamics and the valve function. The detailed analysis of aortic valve hemodynamics would lead to a better understanding of the disease’s etiology. We computationally modeled the aortic valve using simplified three-dimensional geometry and inlet velocity conditions obtained via echocardiography. We examined various calcification severities and bicuspid valve formation. Fluid-structure interaction (FSI) analyses were adapted using ANSYS Workbench to incorporate both flow dynamics and leaflet deformation accurately. Simulation results were validated by comparing leaflet movements in B-mode echo recordings. Results indicate that the biomechanical environment is significantly changed for calcified and bicuspid valves. High flow jet velocities are observed in the calcified valves which results in high transvalvular pressure difference (TPG). Wall shear stresses (WSS) increased with the ca...

Computational assessment of bicuspid aortic valve wall-shear stress: implications for calcific aortic valve disease

Biomechanics and Modeling in Mechanobiology, 2012

The bicuspid aortic valve (BAV) is associated with a high prevalence of calcific aortic valve disease (CAVD). Although abnormal hemodynamics has been proposed as a potential pathogenic contributor, the native BAV hemodynamic stresses remain largely unknown. Fluid-structure interaction models were designed to quantify the regional BAV leaflet wall-shear stress over the course of CAVD. Systolic flow and leaflet dynamics were computed in two-dimensional tricuspid aortic valve (TAV) and type-1 BAV geometries with different degree of asymmetry (10 and 16% eccentricity) using an arbitrary Lagrangian–Eulerian approach. Valvular performance and regional leaflet wallshear stress were quantified in terms of valve effective orifice area (EOA), oscillatory shear index (OSI) and temporal shear magnitude (TSM). The dependence of those characteristics on the degree of leaflet calcification was also investigated. The models predicted an average reduction of 49% in BAV peak-systolic EOA relative to the TAV. Regardless of the anatomy, the leaflet wall-shear stress was side-specific and characterized by high magnitude and pulsatility on the ventricularis and low magnitude and oscillations on the fibrosa. While the TAV and non-coronary BAV leaflets shared similar shear stress characteristics, the base of the fused BAV leaflet fibrosa exhibited strong abnormalities, which were modulated by the degree of calcification (6-fold, 10-fold and 16-fold TSM increase in the normal, mildly and severely calcified BAV, respectively, relative to the normal TAV). This study reveals the existence of major differences in wall-shear stress pulsatility and magnitude on TAV and BAV leaflets. Given the ability of abnormal fluid shear stress to trigger valvular inflammation, the results support the existence of a mechano-etiology of CAVD in the BAV.

Comparison of biomechanical and structural properties between human aortic and pulmonary valve

European Journal of Cardio-Thoracic Surgery

Pulmonary valve autografts have been reported as clinically effective for replacement of diseased aortic valve (Ross procedure). Published data about pulmonary valve mechanical and structural suitability as a long-term substitute for aortic valve are limited. The aim of this study was to compare aortic and pulmonary valve properties. Experimental studies of biomechanical properties and structure of aortic and pulmonary valves were carried out on pathologically unchanged human heart valves, collected from 11 cadaveric hearts. Biomechanical properties of 84 specimens (all valve elements: cusps, fibrous ring, commissures, sinotubular junction, sinuses) were investigated using uniaxial tensile tests. Ultrastructure was studied using transmission and scanning electron microscopy. Ultimate stress in circumferential direction for pulmonary valve cusps is higher than for aortic valve (2.78+/-1.05 and 1.74+/-0.29 MPa, respectively). Ultimate stress in radial direction for pulmonary and aorti...

Fully coupled fluid–structure interaction model of congenital bicuspid aortic valves: effect of asymmetry on hemodynamics

Medical & Biological Engineering & Computing, 2013

A bicuspid aortic valve (BAV) is a congenital cardiac disorder where the valve consists of only two cusps instead of three, as in a normal tricuspid valve (TAV). Although 97 % of BAVs include asymmetric cusps, little or no prior studies have investigated the blood flow through a three-dimensional BAV and root. The aim of the present study was to characterize the effect of asymmetric BAV on the blood flow using fully coupled fluid-structure interaction (FSI) models with improved boundary conditions and tissue properties. This study presents four FSI models, including a native TAV, asymmetric BAVs with or without a raphe, and an almost symmetric BAV. Cusp tissue is composed of hyperelastic finite elements with collagen fibres embedded in the elastin matrix. A full cardiac cycle is simulated by imposing the same physiological blood pressures for all the TAV and BAV models. The latter have significantly smaller opening areas compared with the TAV. Larger stress values were found in the cusps of BAVs with fused cusps, at both the systolic and diastolic phases. The asymmetric geometry caused asymmetric vortices and much larger flow shear stress on the cusps which could be a potential initiator for early valvular calcification of BAVs.

A fluid–structure interaction model of the aortic valve with coaptation and compliant aortic root

Medical & Biological Engineering & Computing, 2012

Native aortic valve cusps are composed of collagen fibers embedded in their layers. Each valve cusp has its own distinctive fiber alignment with varying orientations and sizes of its fiber bundles. However, prior mechanical behavior models have not been able to account for the valve-specific collagen fiber networks (CFN) or for their differences between the cusps. This study investigates the influence of this asymmetry on the hemodynamics by employing two fully coupled fluid-structure interaction (FSI) models, one with asymmetricmapped CFN from measurements of porcine valve and the other with simplified-symmetric CFN. The FSI models are based on coupled structural and fluid dynamic solvers. The partitioned solver has nonconformal meshes and the flow is modeled by employing the Eulerian approach. The collagen in the CFNs, the surrounding elastin matrix, and the aortic sinus tissues have hyperelastic mechanical behavior. The coaptation is modeled with a masterslave contact algorithm. A full cardiac cycle is simulated by imposing the same physiological blood pressure at the upstream and downstream boundaries for both models. The mapped case showed highly asymmetric valve kinematics and hemodynamics even though there were only small differences between the opening areas and cardiac outputs of the two cases. The regions with a less dense fiber network are more prone to damage since they are subjected to higher principal stress in the tissues and a higher level of flow shear stress. This asymmetric flow leeward of the valve might damage not only the valve itself but also the ascending aorta.

Comparison of biomechanical and structural properties between human aortic and pulmonary valve*1

European Journal of Cardio-Thoracic Surgery, 2004

Objective: Pulmonary valve autografts have been reported as clinically effective for replacement of diseased aortic valve (Ross procedure). Published data about pulmonary valve mechanical and structural suitability as a long-term substitute for aortic valve are limited. The aim of this study was to compare aortic and pulmonary valve properties. Methods: Experimental studies of biomechanical properties and structure of aortic and pulmonary valves were carried out on pathologically unchanged human heart valves, collected from 11 cadaveric hearts. Biomechanical properties of 84 specimens (all valve elements: cusps, fibrous ring, commissures, sinotubular junction, sinuses) were investigated using uniaxial tensile tests. Ultrastructure was studied using transmission and scanning electron microscopy. Results: Ultimate stress in circumferential direction for pulmonary valve cusps is higher than for aortic valve (2.78^1.05 and 1.74^0.29 MPa, respectively). Ultimate stress in radial direction for pulmonary and aortic cusps is practically the same (0.29^0.06 and 0.32^0.04 MPa, respectively). In ultrastructural study, different layout and density in each construction element are determined. The aortic and pulmonary valves have common ultrastructural properties. Conclusions: Mechanical differences between aortic and pulmonary valve are minimal. Ultrastructural studies show that the aortic and pulmonary valves have similar structural elements and architecture. This investigation suggests that the pulmonary valve can be considered mechanically and structurally suitable for use as an aortic valve replacement. q