Study on the Parameters Affecting Oxygen Release Time Measurements by Amperometry (original) (raw)
Related papers
A sensitive measurement of oxygen uptake rate using a optochemical sensor
Biotechnology Techniques, 1993
The ~eas~e~~~t 3f the specific oxygen uptake rate (OUR) of slow growing organisms using a small sample size is often hampered by the consumption of oxygen by the electrode used. Using a optochemical sensor we measured the OUR of carrot embryos with appro~mately 1000 cell clusters and of hybridoma with a~pro~mately lo6 cells. An OUR as low as 0.02 ,umolfh can be accurately measured.
Analysis of PhysicoChemical Processes in an Amperometric Oxygen Biosensor
Amperometric techniques are commonly used in lab-ona-chip systems to sense various blood gas analytes such as H+, CO 2 , O 2 , etc. In the present study, a microchip-based amperometric biosensor, being developed as a part of plastic-based structurally programmable microfluidic chip for clinical diagnostics at University of Cincinnati, is analyzed. For accurate modeling of electrokinetic transport and detection of various electroactive species, two levels of modeling are coupled: (i) fluid flow and transport of analytes and (ii) electrochemical surface reactions. In the present work, we have coupled the electrokinetic transport module [1][2] with electrochemical surface reaction solver. A detailed analysis of the system at the diffusion limit reveals that although the temperature variations are insignificant, the measured signal varies significantly due to Joule heating. An interesting phenomenon of increased sensitivity due to electrode-edge effect, caused by singularity at electrode edges, is also be observed and discussed.
How low does the oxygen concentration go within a sandwich-type amperometric biosensor?
Software for the automatic non-linear least squares fit of chronoamperometric responses corresponding to sandwich-type amperometric biosensors has been developed. The so-called Simplex algorithm computes a minimum value for the difference between experimental and theoretical data. The latter consider a numerical model based on a ping-pong reaction mechanism corresponding to an oxidase enzyme that has been immobilized between diffusion membranes.
The accuracy of oxygen flux measurements using microelectrodes
Water Research, 1998
ÐAn electrochemical analog of a bio®lm was constructed to test the accuracy of oxygen¯ux measurements using microelectrodes. We used a cathodically polarized graphite felt attached to the bottom of a¯at plate open channel reactor as the reactive surface consuming oxygen. The oxygen¯ux to the felt was calculated from the polarization current. Microelectrodes were used to measure the oxygen pro®les above and within the graphite felt. From the shape of the oxygen pro®le we evaluated the oxy-gen¯ux to the graphite felt. This provided us with two sets of data, the true oxygen¯ux, calculated from polarization current, and the oxygen¯ux estimated from microelectrode measurements. Comparing these two¯uxes, for dierent¯ow velocities, showed that the¯uxes evaluated from the polarization current were dierent from those evaluated from the oxygen pro®les. The dierences were likely caused by the presence of the microelectrode in the mass boundary layer and/or by the simplifying assumptions accepted in computational procedures employed to calculate oxygen¯uxes. For low¯ow velocities, between zero and 1.0 cm s À1 , the dierences were velocity sensitive; the higher the¯ow velocity, the bigger the dierence. For higher¯ow velocities, between 1 cm s À1 and 3 cm s À1 , the¯ux of oxygen estimated from the microelectrode measurements was consistently approximately 80% higher than the true oxygen¯ux estimated from the polarization current.
Sensors and Actuators B-chemical, 2015
A mathematical model to describe the amperometric response of a sandwich-type biosensor containing polyphenol oxidase as the recognition catalytic element is proposed. The model was solved numerically and the resulting nonlinear solution was used to simulate chronoamperometric curves as well as to estimate the concentration profiles of reagents and products of the enzymatic reaction within the sensor. Fromm's systematic method was applied to get a kinetic expression for the analysis of polyphenol oxidase enzymes. The simulated data are compared with curves corresponding to a biosensor prepared with an oxidase enzyme that reacts according to a ping-pong mechanism. Although in both cases oxygen is used as mediator of the enzymatic reaction, the electrochemical step can generate it back from the H 2 O 2 released by enzymes such as glucose oxidase but it cannot do the same in the case of working with polyphenol oxidase. Most of the calculated profiles and related data are presented using dimensioned variables so that they can be directly compared with experimental results. Relevant parameters such as limit current, response-time, and sensitivity are analyzed as function of the thickness of membranes, concentration of enzyme and concentration of substrate.
Electrochem
Biosensor behaviour is characterised by non-linear differential equations that describe well-defined physical, chemical, and biological processes. Mathematical modelling of these biosensors is highly desirable since they have many applications. These models enable the prediction of a variety of their properties. In this study, the cyclic conversion of the substrate in an amperometric biosensor with an oxidase enzyme membrane electrode is studied using a mathematical model. The governing parameters for the Michaelis–Menten kinetics of enzymatic reactions are the enzyme kinetic and diffusion rates across the enzymatic layer. In this paper, we solved the non-linear equations analytically and numerically for all experimental values of parameters. This problem is simulated in MATLAB® v2016b software using the PDE solver. Our analytical solutions are compared to simulation results to validate the proposed model.