Exergoeconomic analysis of solar photovoltaic power plants: Case study in differents tropicals zone (Maroua and Douala) in Cameroon (original) (raw)
Related papers
Exergoeconomic analysis of a solar photovoltaic-based direct evaporative air-cooling system
Solar Energy, 2019
The target of this work is to perform the exergoeconomic analysis of a solar photovoltaic-based direct evaporative air-cooling system. The system was investigated experimentally with different thicknesses of cellulose and straw pads. For inlet air rates up to 1000 m 3 /h, the maximum changes in the humidity and temperature of outlet air are achieved by a pad with a thickness of 30 cm. A comprehensive mathematical model was developed for the system and the exergoeconomic analysis of the system was carried out. The influence of the effective parameter on the performance of the system was investigated. For an inlet air with a temperature of 30°C and relative humidity of 30%, the maximum system exergy efficiency was obtained about 20%. With changes in the water temperature from 15 to 27°C, inlet air rate from 300 to 1500 m 3 /h, and inlet air temperature from 26 to 34°C, the system exergoeconomic factor changes up to 60%. The current system was compared with a conventional system and results showed that for four early years of systems lifetime, the exergoeconomic factor of the conventional system is greater than the solar system due to its lower initial investment, and for later years is lower due to its larger operating cost.
This work describes and analyses the Rankine cycle of the 50 MW parabolic trough power plant Andasol 1 in the Spanish region of Andalusia, a prime example of the use of solar energy for electricity generation. By means of an exergoeconomic analysis, all components of the thermal plant are considered individually. Thermodynamic inefficiencies within the system are located, quantified and economically evaluated. Generally, various wet and dry cooling methods come into consideration for the re-cooling of the steam. Andasol 1 uses the more effective wet cooling method, because in the vicinity sufficient water reserves are available. In this work, the water-cooled system is replaced by an air-cooled condenser and the two variants are compared under exergoeconomics aspects. Also the impact of a construction of Andasol 1 in a hotter and drier climate than the northern Sahara is simulated. The analysis shows that within the air-cooled condenser much more exergy is destroyed than within the ...
Exergoeconomic analysis of a combined solar-waste driven power plant
Renewable Energy, 2019
In this work, a thorough exergoeconomic analysis of a hybrid solar-waste driven power plant is presented. The objective is to give a clearer picture of the main irreversibilities, their corresponding costs and to find some effective yet feasible solutions to improve the efficiency and cost-effectiveness of the power plant. For this, the power plant is exergetically modeled, the exergoeconomic assessment is accomplished, the exergy losses are weighted, the cost of these losses are estimated and finally, the solutions are given. The cost of electricity was improved from 0.202 US$/MJ to 0.137 US$/MJ, after the application of the recommendations. Results show that electricity cost decreases in daily hours from a maximum of 10% in winter to the maximum of 26% in summer. Furthermore, the results of sensitivity analysis on the plant indicates that a hybrid cycle with turbine isentropic efficiency of 0.85, steam extraction ratio of 0.36 and inlet turbine temperature of 400 ℃ offers a 32% lower electricity cost compared to a cycle with a turbine isentropic efficiency of 0.75, steam extraction ratio of 0.16 and inlet turbine temperature of 500 ℃.
Exergoeconomic assessment, parametric study and optimization of a novel solar trigeneration system
International Journal of Renewable Energy Research, 2016
An exergoeconomic analysis is performed for a solar trigeneration system in which the electric power, refrigeration power and domestic hot water are produced by a cascade organic Rankine cycle, an absorption chiller, which is accompanied by ammonia turbine, and a heat recovery cycle respectively. A parametric study is also carried out to investigate the effects of such significant parameters as degree of superheat at the turbine’s inlet of power cycle, condenser temperature of power cycle, operating pressure of the refrigerating cycle and operating fluid temperature of the main cycle on the energy and exergy efficiencies and the exergoeconomic performance of the system. Finally a multi objective optimization from the viewpoint of exergoeconomics is reported by using genetic algorithm. As a result of exergoeconomic analysis of the system, ORC Heat Exchanger (ORC Ex), Cooling Tower2 (C.T2), Absorber (Abs) and Reflux Condenser (Ref Cond) exhibit the worst exergoeconomic performance. Fo...
Exergoeconomic Analysis of a Solar Photovoltaic Module in Karabük, Turkey
2016
This paper deals with the exergoeconomic analysis of a 130 Watt-peak (Wp) solar photovoltaic (PV) panel that is constructed at the top of Engineering Faculty of Karabuk University (41.12 N, 32.39 W) in Karabuk province, Turkey. It is known that seasonal differences cause a variation in the exergoeconomic parameters (energy and exergy loss rates) of solar PV systems. Due to this perspective, for regional climatic parameters four days in November are selected. Within this research, first the exergy analysis is performed on the system and then the economic values of the results are evaluated using the exergy, cost, energy, and mass method. The energy efficiency of the considered system in November varies between 9,6% and 17,1%, respectively. Additionally, the exergy efficiency of the system in November varies between 9,2% and 15,8% respectively. The average unit cost of the exergy values for November are calculated based on the model as 0.191 W/$ and 0.392 W/$ which are the minimum and...
Energies
The present study investigates low-grade heat utilization in ejector refrigeration systems under hot climatic conditions. A variable area ejector is used to maximize the harvested heat from the generator of the solar system at peak times. Exergy, economic, and exergoeconomic analyses are conducted to evaluate the performance of the system. A thermodynamic model of the system has been developed using Ebsilon Professional software. Available experimental and theoretical data validate the results. The effects of properties of the working fluids, ejector geometry, and operation conditions are also evaluated. It was found that the coefficient of performance of the system reached 0.45 at a generator pressure of 3 bars. Furthermore, it was noticed that the overall exergy efficiency could be increased for a fixed generator temperature while increasing the ejector area ratio. A value of 21% exergetic efficiency was calculated for the system. The exergoeconomic analysis of the system demonstr...
Sustainable Energy Technologies and Assessments, 2021
This paper assesses the technical and economic viability of a hybrid water-based mono-crystalline silicon (mc-Si) photovoltaic-thermal (PVT) module in comparison with a conventional mc-Si photovoltaic (PV) module installed in Ghana. Analytical models are developed to analyze the technical and economic performance of the systems over a 25-year period. The study shows that although the PVT system is more expensive to setup, it generally performs better than the conventional PV system when both systems are installed with batteries. The estimated average yearly total exergy to load from PV and PVT subsystems are respectively 159.42 kWh/m 2 and 330.15 kWh/m 2. The levelized cost of exergy (LCOEx) from the PV and PVT basic systems are US$ 0.45/kWh and US$ 0.33/kWh respectively for average peak sun hours (S h) of 4.6 h (installation site). Varying S h from 4.6 h to 6.5 h (northmost regions of Ghana) reduces the LCOEx for the PV and PVT systems by approximately 18% and 11% respectively. The PV system however becomes more economically viable than the PVT system when both systems are installed without batteries.
An economic viability analysis and optimization of solar cooling system
Proceedings of the 4th …, 2009
Abstract: A procedure is presented for assessing the economic viability of a solar cooling system in terms of the life cycle savings function. The optimization is carried out for a solar cooling system that has been designed for Malaysia and similar tropical regions using evacuated tube solar collectors and ammonia-water absorption unit. The life cycle savings is expressed in a generalized form in terms of two economic parameters, P1 and P2, which relate all life cycle cost considerations to the first year fuel cost or the initial solar system ...
Solar Energy, 2016
In the present article attempt is made to develop an exergoeconomic optimization model to integrate solar energy into trigeneration system producing electricity, heating and cooling according to the exergetic, economic and environmental targets. The results show that by selecting final optimum solution for the trigeneration system, the unit cost of products reduced by 11.5% and exergy efficiency increased from 44.38% in the base case to 56.07% in the optimum case. The application of optimization process shows that exergoeconomic analysis improved significantly the total performance of the trigeneration system in a way that fuel cost, exergy destruction cost and environmental impacts (CO 2 emissions cost) are reduced by 24.17%, 38.87% and 24.17%. Finally, sensitivity analysis is carried out to examine the effect of changes in the trigeneration Pareto optimal solutions and the unit cost of products to the important economic parameters, such as interest rate, fuel cost, system operation period, and construction period.
Exergetic performance assessment of an integrated solar energy system
International Journal of Exergy, 2016
In this study, an integrated solar absorption-cooling and heating system is taken as a basis to develop a multi-generation solar system with five outputs, namely electricity, heat, hot water, cooling, and air conditioning (humidifying/ dehumidifying) for residential use. The system performance is assessed by energy and exergy efficiencies. The present system is capable of producing 550 kW of electricity. The exergy efficiencies and exergy destruction rates are examined under the variation of ambient conditions. The results show that the maximum exergy efficiency for the overall system is 28%. It is also found that the main sources of exergy destruction rate are the solar collectors and ORC turbines and evaporators. Therefore, this study points out the importance of the selection and design of these to reduce exergy destruction, and as a result, increase the exergy efficiency of the system by minimising irreversibilities.