Quantification of colorimetric isothermal amplification on the smartphone and its open-source app for point-of-care pathogen detection (original) (raw)

SMART-LAMP: A Smartphone-Operated Handheld Device for Real-Time Colorimetric Point-of-Care Diagnosis of Infectious Diseases via Loop-Mediated Isothermal Amplification

Biosensors

Nucleic acid amplification diagnostics offer outstanding features of sensitivity and specificity. However, they still lack speed and robustness, require extensive infrastructure, and are neither affordable nor user-friendly. Thus, they have not been extensively applied in point-of-care diagnostics, particularly in low-resource settings. In this work, we have combined the loop-mediated isothermal amplification (LAMP) technology with a handheld portable device (SMART-LAMP) developed to perform real-time isothermal nucleic acid amplification reactions, based on simple colorimetric measurements, all of which are Bluetooth-controlled by a dedicated smartphone app. We have validated its diagnostic utility regarding different infectious diseases, including Schistosomiasis, Strongyloidiasis, and COVID-19, and analyzed clinical samples from suspected COVID-19 patients. Finally, we have proved that the combination of long-term stabilized LAMP master mixes, stored and transported at room tempe...

Portable real-time colorimetric LAMP-device for rapid quantitative detection of nucleic acids in crude samples

2020

Loop-mediated isothermal amplification is known for its high sensitivity, specificity and tolerance to inhibiting-substances. We developed a device for performing real-time colorimetric LAMP combining the accuracy of lab-based quantitative molecular diagnosis with the simplicity of point-of-care testing. This handheld device employs a single reaction-pot for amplification and a mini-camera for detection. Competitive features are the rapid analysis (<30min), quantification over 9 log-units, crude sample-compatibility (saliva, tissue, swabs), low detection limit (<5copies/reaction), smartphone-operation and fast prototyping (3D-printing). The device’s clinical utility is demonstrated in cancer-mutations and COVID-19 testing. Excellent performance includes: detection of 0.01% of BRAF-V600E-to-wild-type molecules; 97% sensitivity to SARS-CoV-2 RNA detection (89 samples); 83% (Ct<34), 98% (Ct<30) and 100% (Ct<25) to 163 nasopharyngeal-swabs; 100% specificity in all cases. ...

Real-time colorimetric LAMP methodology for quantitative nucleic acids detection at the point-of-care

2020

Most methods applied to nucleic acids' detection at the point-of-care require either expensive and mostly bench-top instruments or simpler inexpensive systems providing qualitative results. Truly decentralized approaches to reliable, quantitative and affordable diagnostics are still missing. Here, we report the development of real-time quantitative colorimetric LAMP based on a portable and cost-effective device, the use of which requires minimal training. Main advantages of the method are the rapid analysis time (<30min); quantification over a large dynamic range (9 log units); ability to work with crude samples (saliva, tissue); demonstrated low detection limit (1-10 copies); smartphone-operation and fast prototyping (3D-printing). The system's broad detection capability is demonstrated during infectious diseases-testing for COVID-19 and pharmacogenetics for BRAF V600E mutation testing. Validation studies showed 97.4% and 100% agreement with qRT-PCR for SARS-CoV-2 RNA detection extracted from positive and negative patients' samples (89), respectively; and 100% agreement with ddPCR and Sanger sequencing for BRAF V600E mutation detection from 12 clinical biopsy samples. The new methodology provides a needed solution for affordable healthcare at the point-of-care, with emphasis on global diagnostics.

A Robust, Low-Cost Instrument for Real-time Colorimetric Isothermal Nucleic Acid Amplification

2021

The COVID-19 pandemic has highlighted the need for broader access to molecular diagnostics. Colorimetric isothermal nucleic acid amplification assays enable simplified instrumentation over more conventional PCR diagnostic assays and, as such, represent a promising approach for addressing this need. In particular, colorimetric LAMP (loop-mediated isothermal amplification) has received a great deal of interest recently. However, there do not currently exist robust instruments for performing these kinds of assays in high throughput with real-time readout of amplification signals. To address this need, we developed LARI, the LAMP Assay Reader Instrument. We have deployed over 50 LARIs for routine use in R&D and production environments, with over 12,000 assays run to date. In this paper, we present the design and construction of LARI along with thermal, optical, and assay performance characteristics. LARI can be produced for under $1500 and has broad applications in R&D, point-of-care di...

Mobile Platform for Multiplexed Detection and Differentiation of Disease-Specific Nucleic Acid Sequences, Using Microfluidic Loop- Mediated Isothermal Amplification and Smartphone Detection

New tools are needed to enable rapid detection, identification, and reporting of infectious viral and microbial pathogens in a wide variety of point-of-care applications that impact human and animal health. We report the design, construction, and characterization of a platform for multiplexed analysis of disease-specific DNA sequences that utilizes a smartphone camera as the sensor in conjunction with a hand-held " cradle " that interfaces the phone with a silicon-based microfluidic chip embedded within a credit-card-sized cartridge. Utilizing specific nucleic acid sequences for four equine respiratory pathogens as representative examples, we demonstrated the ability of the system to utilize a single 15 μL droplet of test sample to perform selective positive/negative determination of target sequences, including integrated experimental controls, in approximately 30 min. Our approach utilizes loop-mediated isothermal amplification (LAMP) reagents predeposited into distinct lanes of the microfluidic chip, which when exposed to target nucleic acid sequences from the test sample, generates fluorescent products that when excited by appropriately selected light emitting diodes (LEDs), are visualized and automatically analyzed by a software application running on the smartphone microprocessor. The system achieves detection limits comparable to those obtained by laboratory-based methods and instruments. Assay information is combined with the information from the cartridge and the patient to populate a cloud-based database for epidemiological reporting of test results.

Smart Cup: A Minimally-Instrumented, Smartphone-Based Point-of-Care Molecular Diagnostic Device

Sensors and actuators. B, Chemical, 2016

Nucleic acid amplification-based diagnostics offer rapid, sensitive, and specific means for detecting and monitoring the progression of infectious diseases. However, this method typically requires extensive sample preparation, expensive instruments, and trained personnel. All of which hinder its use in resource-limited settings, where many infectious diseases are endemic. Here, we report on a simple, inexpensive, minimally-instrumented, smart cup platform for rapid, quantitative molecular diagnostics of pathogens at the point of care. Our smart cup takes advantage of water-triggered, exothermic chemical reaction to supply heat for the nucleic acid-based, isothermal amplification. The amplification temperature is regulated with a phase-change material (PCM). The PCM maintains the amplification reactor at a constant temperature, typically, 60-65°C, when ambient temperatures range from 12 to 35°C. To eliminate the need for an optical detector and minimize cost, we use the smartphone&#3...

Low-Cost, Open-Source Device for High-Performance Fluorescence Detection of Isothermal Nucleic Acid Amplification Reactions

The ability to detect SARS-CoV-2 is critical to implementing evidence-based strategies to address the COVID-19 global pandemic. Expanding SARS-CoV-2 diagnostic ability beyond well-equipped laboratories widens the opportunity for surveillance and control efforts. However, such advances are predicated on the availability of rapid, scalable, accessible, yet highperformance diagnostic platforms. Methods to detect viral RNA using reverse transcription loop-mediated isothermal amplification (RT-LAMP) show promise as rapid and field-deployable tests; however, the per-unit costs of the required diagnostic hardware can be a barrier for scaled deployment. Here, we describe a diagnostic hardware configuration for LAMP technology, named the FABL-8, that can be built for approximately US$380 per machine and provide results in under 30 min. Benchmarking showed that FABL-8 has a similar performance to a high-end commercial instrument for detecting fluorescence-based LAMP reactions. Performance testing of the instrument with RNA extracted from a SARS-CoV-2 virus dilution series revealed an analytical detection sensitivity of 50 virus copies per microlitera detection threshold suitable to detect patient viral load in the first few days following symptom onset. In addition to the detection of SARS-CoV-2, we show that the system can be used to detect the presence of two bacterial pathogens, demonstrating the versatility of the platform for the detection of other pathogens. This cost-effective and scalable hardware alternative allows democratization of the instrumentation required for high-performance molecular diagnostics, such that it could be available to laboratories anywheresupporting infectious diseases surveillance and research activities in resource-limited settings.

A Rotatable Paper Device Integrating Reverse Transcription Loop-Mediated Isothermal Amplification and a Food Dye for Colorimetric Detection of Infectious Pathogens

Biosensors

In this study, we developed a rotatable paper device integrating loop-mediated isothermal amplification (RT-LAMP) and a novel naked-eye readout of the RT-LAMP results using a food additive, carmoisine, for infectious pathogen detection. Hydroxyl radicals created from the reaction between CuSO4 and H2O2 were used to decolor carmoisine, which is originally red. The decolorization of carmoisine can be interrupted in the presence of DNA amplicons produced by the RT-LAMP reaction due to how DNA competitively reacts with the hydroxyl radicals to maintain the red color of the solution. In the absence of the target DNA, carmoisine is decolored, owing to its reaction with hydroxyl radicals; thus, positive and negative samples can be easily differentiated based on the color change of the solution. A rotatable paper device was fabricated to integrate the RT-LAMP reaction with carmoisine-based colorimetric detection. The rotatable paper device was successfully used to detect SARS-CoV-2 and SARS...

LOOP MEDIATED ISOTHERMAL AMPLIFICATION BASED DETECTION OF EQUINE RESPIRATORY PATHOGENS USING A PORTABLE, SMARTPHONE-BASED SETUP

New tools are needed to enable rapid detection, identification, and reporting of infectious viral and microbial pathogens in a wide variety of point-of-care applications that impact human and animal health. We report the design, construction, and characterization of a multiplexed platform for multiplexed analysis of disease-specific DNA sequences that utilizes a smartphone camera as the sensor in conjunction with a handheld "cradle" that interfaces the phone with a silicon-based microfluidic chip embedded within a credit card-sized cartridge. Utilizing specific nucleic acid sequences for four equine respiratory pathogens as representative examples, we demonstrate the ability of the system to utilize a single 15 µL droplet of test sample to perform selective positive/negative determination of target sequences, including integrated experimental controls, in approximately 30 minutes. Our approach utilizes loop mediated isothermal amplification (LAMP) reagents pre-deposited into distinct lanes of the microfluidic chip, which, when exposed to target nucleic acid sequences from the test sample, generates fluorescent products that, when excited by appropriately selected light emitting diodes (LEDs) are visualized and automatically analyzed by a software application running on the smartphone microprocessor. The system achieves detection limits comparable to those obtained by laboratory-based methods and instruments. Assay information is combined with information from the cartridge and the patient to populate a cloudbased database for epidemiological reporting of test results.

Cleavable hairpin beacon-enhanced fluorescence detection of nucleic acid isothermal amplification and smartphone-based readout

Scientific Reports, 2020

Fluorescence detection of nucleic acid isothermal amplification utilizing energy-transfer-tagged oligonucleotide probes provides a highly sensitive and specific method for pathogen detection. However, currently available probes suffer from relatively weak fluorescence signals and are not suitable for simple, affordable smartphone-based detection at the point of care. Here, we present a cleavable hairpin beacon (CHB)-enhanced fluorescence detection for isothermal amplification assay. The CHB probe is a single fluorophore-tagged hairpin oligonucleotide with five continuous ribonucleotides which can be cleaved by the ribonuclease to specifically initiate DNA amplification and generate strong fluorescence signals. By coupling with loop-mediated isothermal amplification (LAMP), the CHB probe could detect Borrelia burgdorferi (B. burgdorferi) recA gene with a sensitivity of 100 copies within 25 min and generated stronger specific fluorescence signals which were easily read and analysed by...