Concomitant Electrophysiological Study with Transcatheter Aortic Valve Implantation to Predict Risk of Atrioventricular Block (original) (raw)

Permanent pacing after transcatheter aortic valve implantation of a CoreValve prosthesis as determined by electrocardiographic and electrophysiological predictors: a single-centre experience

Europace, 2015

The most frequent conduction complications with transcatheter aortic valve implantation (TAVI) are complete atrioventricular (AV) block and new bundle branch block (BB). The purpose of this study was to assess clinical, electrocardiographic, and electrophysiological predictors of conduction abnormalities in patients (pts) undergoing TAVI with the CoreValve prosthesis. The secondary end points were the long-term rhythm follow-up and the recovery of conduction. Methods and results Forty-five consecutive pts with severe aortic stenosis, New York Heart Association II/III, and normal or slightly impaired left ventricular function who underwent CoreValve transcatheter implantation were randomized 2:1 to electrocardiographic and electrocardiographic plus electrophysiological evaluations. Pacemakers were implanted in pts with complete AV block. Follow-up was performed at 1, 6, 12, and 24 months. Conduction was affected in the total group of pts undergoing TAVI. The PR lengthened compared with the baseline but did not exceed the normal cutoff of 200 ms, and the QRS widened, basically due to new left bundle branch blocks (LBBBs). Within 1 month of follow-up, 10 pts (22%) developed complete AV block (9 peri-procedurally-20%) and 15 pts (33%) developed a new bundle BB, with LBBBs being the most common (14-31%). In the 30 pts who underwent an electrophysiological study, analysis showed that prolonged HV intervals were prognostic for pacemaker implantation. Follow-up in the total study group revealed that only 4 of the 10 (9%) initial implantations remained completely pacemaker dependent. Conclusion Conduction was affected in all pts undergoing TAVI, but serious complications that required permanent pacing generally occurred in pts with pre-existing conduction abnormalities.

Prognosis assessment of persistent left bundle branch block after TAVI by an electrophysiological and remote monitoring risk-adapted algorithm: rationale and design of the multicentre LBBB-TAVI Study

BMJ open, 2016

Percutaneous aortic valve replacement (transcatheter aortic valve implantation (TAVI)) notably increases the likelihood of the appearance of a complete left bundle branch block (LBBB) by direct lesion of the LBB of His. This block can lead to high-grade atrioventricular conduction disturbances responsible for a poorer prognosis. The management of this complication remains controversial. The screening of LBBB after TAVI persisting for more than 24 hours will be conducted by surface ECG. Stratification will be performed by post-TAVI intracardiac electrophysiological study. Patients at high risk of conduction disturbances (≥70 ms His-ventricle interval (HV) or presence of infra-Hisian block) will be implanted with a pacemaker enabling the recording of disturbance episodes. Those at lower risk (HV <70 ms) will be implanted with a loop recorder device with remote monitoring of cardiovascular implantable electronic devices (CIEDs). Clinical, ECG and implanted device follow-up will also...

Update in Heart Rhythm Abnormalities and Indications for Pacemaker After Transcatheter Aortic Valve Implantation

Brazilian Journal of Cardiovascular Surgery

Objective: Rhythm abnormalities following transcatheter aortic valve implantation (TAVI) and indications for permanent pacemaker implantation (PPI) were reviewed, which aren't well established in the current guidelines. New left bundle branch block and atrioventricular block are the most common electrocardiographic changes after TAVI. PPI incidence ranges from 9-42% for selfexpandable and 2.5-11.5% for balloon expandable devices. Not only anatomical variations in conduction system have an important role in conduction disorders, but different valve characteristics and their relationship with cardiac structures as well. Previous right bundle branch block has been confirmed as one of the most significant predictors for PPI.

Comparison of Incidence and Predictors of Left Bundle Branch Block After Transcatheter Aortic Valve Implantation Using the CoreValve Versus the Edwards Valve

The American Journal of Cardiology, 2013

Conduction disorders and permanent pacemaker implantation are common complications in patients who undergo transcatheter aortic valve implantation (TAVI). The aim of this study was to assess the incidence and clinical significance of new bundle branch block in patients who underwent TAVI with the Medtronic CoreValve Revalving System (MCRS) or the Edwards SAPIEN valve (ESV). Data from 238 patients with no previous pacemaker implantation, left bundle branch block (LBBB) or right bundle branch block at baseline electrocardiography who underwent TAVI with either MCRS (n [ 87) or ESV (n [ 151) bioprostheses from 2007 to 2011 were analyzed. New-onset LBBB occurred in 26.5% patients (n [ 63): 13.5% with the ESV (n [ 20) and 50.0% with the MCRS (n [ 43) (p [ 0.001). Permanent pacemaker implantation was required in 12.7% of patients (n [ 8) because of complete atrioventricular block (ESV n [ 2, MCRS n [ 4), LBBB and first degree atrioventricular block (MCRS n [ 1) and new-onset LBBB associated with sinus bradycardia (MCRS n [ 1). At discharge, LBBB persisted in 8.6% of ESV patients (n [ 13) and 32.2% of MCRS patients (n [ 28) (p [ 0.001).

Severe conduction defects requiring permanent pacemaker implantation in patients with a new-onset left bundle branch block after transcatheter aortic valve implantation

Europace, 2017

Transcatheter aortic valve implantation (TAVI) is frequently associated with cardiac conduction defects (CCD) requiring permanent pacemaker implantation (PPI). Although new-onset left bundle branch block (LBBB) is often seen, the rate of progression to severe CCD is unclear. We aimed to find clinical and electrocardiographic (ECG) parameters associated with severe CCD requiring PPI in patients with a new-onset LBBB after TAVI and assess its effect on clinical outcome. Methods and results All consecutive patients undergoing TAVI who developed a new-onset LBBB were retrospectively analysed. We excluded patients with pre-existing bundle branch block or pacemaker. Patients were divided into two groups: with or without PPI after TAVI. We included 155 patients (50% female, 80 + 7 years), of which 37 (24%) developed CCD requiring PPI, mainly due to a total atrioventricular block (n ¼ 17; 46%). Cardiac conduction defects requiring PPI were associated with the following pre-existing parameters: atrial fibrillation (AF), the use of digoxin, CoreValve implantation, and left heart axis. Furthermore, it was associated with the following post-procedural parameters: left heart axis, lower mean heart rate, and prolonged PQ and QRS times. During follow-up, patients with PPI showed a lower mortality rate (11 vs. 29%, P ¼ 0.03). In patients without PPI, mortality was lower in those with narrower QRS complex and transient LBBB. Conclusion The severity and persistence of a new-onset LBBB after TAVI is associated with mortality. Cardiac conduction defects requiring PPI are associated with prior AF, the use of digoxin, CoreValve implantation, and a left heart axis. In these patients, PPI portends a better prognosis than no PPI.

Permanent Pacing After Transcatheter Aortic Valve Implantation: Incidence, Predictors and Evolution of Left Ventricular Function

Arquivos brasileiros de cardiologia, 2017

Transcatheter aortic valve implantation (TAVI) is a well-established procedure; however, atrioventricular block requiring permanent pacemaker implantation (PPI) is a common complication. To determine the incidence, predictors and clinical outcomes of PPI after TAVI, focusing on how PPI affects left ventricular ejection fraction (LVEF) after TAVI. The Brazilian Multicenter TAVI Registry included 819 patients submitted to TAVI due to severe aortic stenosis from 22 centers from January/2008 to January/2015. After exclusions, the predictors of PPI were assessed in 670 patients by use of multivariate regression. Analysis of the ROC curve was used to measure the ability of the predictors; p < 0.05 was the significance level adopted. Within 30 days from TAVI, 135 patients (20.1%) required PPI. Those patients were older (82.5 vs. 81.1 years; p = 0.047) and mainly of the male sex (59.3% vs 45%; p = 0.003). Hospital length of stay was longer in patients submitted to PPI (mean = 15.7 ± 25.7...

Incidence and Predictors of Atrioventricular Conduction Impairment After Transcatheter Aortic Valve Implantation

American Journal of Cardiology, 2010

Atrioventricular (AV) conduction impairment is well described after surgical aortic valve replacement, but little is known in patients undergoing transcatheter aortic valve implantation (TAVI). We assessed AV conduction and need for a permanent pacemaker in patients undergoing TAVI with the Medtronic CoreValve Revalving System (MCRS) or the Edwards Sapien Valve (ESV). Sixty-seven patients without pre-existing permanent pacemaker were included in the study. Forty-one patients (61%) and 26 patients (39%) underwent successful TAVI with the MCRS and ESV, respectively. Complete AV block occurred in 15 patients (22%), second-degree AV block in 4 (6%), and new left bundle branch block in 15 (22%), respectively. A permanent pacemaker was implanted in 23 patients (34%). Overall PR interval and QRS width increased significantly after the procedure (p <0.001 for the 2 comparisons). Implantation of the MCRS compared to the ESV resulted in a trend toward a higher rate of new left bundle branch block and complete AV block (29% vs 12%, p ‫؍‬ 0.09 for the 2 comparisons). During follow-up, complete AV block resolved in 64% of patients. In multivariable regression analysis pre-existing right bundle branch block was the only independent predictor of complete AV block after TAVI (relative risk 7.3, 95% confidence interval 2.4 to 22.2). In conclusion, TAVI is associated with impairment of AV conduction in a considerable portion of patients, patients with pre-existing right bundle branch block are at increased risk of complete AV block, and complete AV block resolves over time in most patients.

Yield of the electrophysiological study in patients with new-onset left bundle branch block after transcathether aortic valve replacement: The PR interval matters

Frontiers in Cardiovascular Medicine

BackgroundStudies suggest that performing an electrophysiological study (EPS) may be useful to identify patients with new-onset left bundle branch block (LBBB) post-TAVR at risk of atrioventricular block. However, tools to optimize the yield of such strategy are needed. We therefore aimed to investigate whether 12-lead ECG changes post-TAVR may help identify patients with abnormal EPS findings.Materials and methodsConsecutive patients with new-onset LBBB post-TAVR who underwent EPS were included. PR and QRS intervals were measured on 12-lead ECG pre-TAVR and during EPS. Abnormal EPS was defined as an HV interval > 55 ms.ResultsAmong 61 patients, 28 (46%) had an HV interval > 55 ms after TAVR. Post-TAVR PR interval and ΔPR (PR-post–pre-TAVR) were significantly longer in patients with prolonged HV (PR: 188 ± 38 vs. 228 ± 34 ms, p < 0.001, ΔPR: 10 ± 30 vs. 34 ± 23 ms, p = 0.001), while no difference was found in QRS duration. PR and ΔPR intervals both effectively discriminated...

Predictors for permanent pacing after transcatheter aortic valve implantation

Catheterization and Cardiovascular Interventions, 2010

Background: Transcatheter aortic valve implantation (TAVI) is a new treatment strategy for patients with symptomatic aortic stenosis who are high risk for traditional surgical aortic valve replacement. The incidence of conduction system abnormalities after the procedure is significant. We examine our experience with CoreValve TAVI focusing on electrocardiographic changes found pre-, peri-, and postintervention. Methods: During 2007-08 we undertook 33 cases utilizing the CoreValve revalving system (CoreValve, Paris, France). Assessment of ECGs, with particular reference to the PR and QRS duration, was made daily during each patient's hospital stay. Results: Patients were aged 81.7 6 6.7 years and the majority were male (57%). Baseline cardiac rhythm was sinus (n 5 28, 80%); atrial fibrillation (n 5 6, 18%) or ventricular paced (n 5 1, 3%). Following CoreValve implantation, prolongation of both the PR interval and QRS duration was seen. Preprocedural PR interval was 193.5 6 38.7 ms and QRS interval preprocedure was 115.3 6 24.8 ms. PR interval increased after the procedure by 23.5 6 23.9 ms and peaked at day 4 with a mean increase of 66.1 6 72.7 ms. QRS duration increased by a mean of 30.6 6 26.1 ms postprocedure and remained stable thereafter during the remaining hospital stay. The need for PPM insertion was partially predicted by pre-procedural QRS morphology: patients with pre-existing right bundle branch block had an 83% chance of requiring a permanent pacemaker (P < 0.01 OR 28 95%CI 2.4-326.7); those with LBBB had a 33% chance of requiring a pacemaker (P 5 ns OR 2.3 95%CI 0.2-34.9). Patients undergoing the procedure later in our experience showed a decreased incidence of pacing (P 5 0.046 OR 0.36 95% CI 0.07-1.82). Pre-procedural annulus measurements also predicted the requirement for pacing with larger annulus sizes more likely to require a pacemaker (P 5 0.044 OR 3.3 95% CI 0.63-17.6). The requirement for pacing was not predicted by age, baseline PR interval or gender. Requirement for pacing overall was 32% with an additional 13% having had a pacemaker inserted prior to the TAVI. Conclusion: CoreValve insertion was associated with an increase in PR interval and QRS duration. PR interval continued to rise during admission, peaking on Day 4 post procedure, making a prolonged period of monitoring highly desirable. There was a significant requirement for permanent pacing, which was predicted by pre-procedural QRS morphology, annulus measurement, and the learning curve. V C 2010 Wiley-Liss, Inc.

Electrocardiographic Predictors of Long-Term Cardiac Pacing Dependency Following Transcatheter Aortic Valve Implantation

Journal of Cardiovascular Electrophysiology, 2017

Background: Conduction disorders requiring permanent pacemaker (PPM) implantation are a known complication of trans-catheter aortic valve implantation (TAVI). Indications for permanent pacing in this setting are still controversial. The study aim was to characterize the natural history of conduction disorders related to TAVI, and to identify predictors for long term pacing dependency. Methods: Consecutive patients who underwent TAVI were included in this prospective observational study. The conduction system was investigated by reviewing 12-lead ECGs during hospitalization and up to 1-year follow-up and by analyzing pacemaker interrogation data. Multivariate analysis was performed in order to identify independent predictors for pacemaker dependency. Results: Of 110 patients included in the analysis, 38 (34.5%) underwent PPM implantation. Of those, 26 (68.4%) had a long-term pacing dependency (required PPM), while 12 (31.6%) did not (notrequired PPM). Logistic regression revealed that baseline RBBB (P = 0.01, OR = 18.0), baseline PR