On the Gray-Value Sensibility of Dental Practitioners (original) (raw)

Grey value contrast sensitivity of dental practitioners in function of luminance and age

Wolfgang Jacquet

Dentomaxillofacial Radiology, 2019

View PDFchevron_right

Could standardizing "commercial off-the-shelf" (COTS) monitors to the DICOM part 14: GSDF improve the presentation of dental images? A visual grading characteristics analysis

Jonathan McNulty

Dentomaxillofacial Radiology, 2013

View PDFchevron_right

Introduction to Grayscale Calibration and Related Aspects of Medical Imaging Grade Liquid Crystal Displays

Vasundhara Bajpai

Journal of Digital Imaging, 2008

View PDFchevron_right

DICOM GSDF calibration.

Daniel McIlgorm, Jonathan McNulty

View PDFchevron_right

Color and contrast perception in monochrome medical imaging flat-panel displays

aldo badano

Medical Imaging 2001: Image Perception and Performance, 2001

View PDFchevron_right

Could standardising commercial off-the-shelf (COTS) monitors to the DICOM part 14: GSDF affect clinical diagnosis? A visual grading characteristics analysis

Jonathan McNulty

View PDFchevron_right

Technical Note: Gray tracking in medical color displays-A report of Task Group 196

Danny Deroo

Medical physics, 2016

View PDFchevron_right

Different pixel pitch and maximum luminance of medical grade displays may result in different evaluations of digital radiography images

Alberto Laffranchi

La Radiologia medica, 2018

View PDFchevron_right

Grey scale measurements of video displays

Vytenis Punys

View PDFchevron_right

Automatic exposure compensation in intraoral digital radiography: effect on the gray values of dental tissues

Maria dos Anjos Pontual

BMC Medical Imaging, 2022

View PDFchevron_right

Effect of display type, DICOM calibration and room illuminance in bitewing radiographs

Esa Liukkonen

Dentomaxillofacial Radiology, 2016

View PDFchevron_right

DICOM gray-scale standard display function: clinical diagnostic accuracy of chest radiography in medical-grade gray-scale and consumer-grade color displays

Antonio Salazar

AJR. American journal of roentgenology, 2014

View PDFchevron_right

Prediction of Perceptibility Curves of direct digital intraoral radiographic systems

xie Shi

Dentomaxillofacial Radiology, 1999

View PDFchevron_right

Medical Imaging Displays and Their Use in Image Interpretation

Athanasios Diamantopoulos

RadioGraphics, 2013

View PDFchevron_right

Performance characteristics and image fidelity of gray-scale monitors

M. I Boechat

RadioGraphics, 1992

View PDFchevron_right

The assessment of diagnostic medical images using 10-bit grayscale - fact or myth?

Andrzej S . Urbanik

Polish journal of radiology, 2018

View PDFchevron_right

Display characterization by eye: contrast ratio and discrimination throughout the grayscale

James Larimer

Human Vision and Electronic Imaging IX, 2004

View PDFchevron_right

Image quality in digital radiographic systems

ANA JULIA GOIS DE OLIVEIRA

Brazilian Dental Journal, 2003

View PDFchevron_right

Comparison of Color LCD and Medical-grade Monochrome LCD Displays in Diagnostic Radiology

Lillemor Forsberg, Mats Geijer

Journal of Digital Imaging, 2007

View PDFchevron_right

Psychophysical evaluation of calibration curve for diagnostic LCD monitor

hideki fujita

Radiation Medicine, 2006

View PDFchevron_right

The effect of viewing conditions on reader performance in radiographic images

Abbas Moghimbeigi

2013

View PDFchevron_right

Impact of viewing conditions on the performance assessment of different computer monitors used for dental diagnostics

Johan Aps

Imaging Science in Dentistry

View PDFchevron_right

Effect of monitors on approximal caries detection in digital radiographs—standard versus precalibrated DICOM part 14 displays: An in vitro study

Arne Petersson

Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, 2009

View PDFchevron_right

Correlation between Quantitative and Qualitative Analysis on Image Quality of Digital Dental X-ray Images

Haslina Taib

Journal of Computer Science & Computational Mathematics, 2012

View PDFchevron_right

Clinical utilization of grayscale workstations

Ricky Taira

IEEE Engineering in Medicine and Biology Magazine, 2000

View PDFchevron_right

Evaluation of Performance of different display systems used in Nuclear Medicine Imaging

Subhash Kheruka

2015

View PDFchevron_right

Psychophysical contrast calibration

Eli Peli

Vision Research, 2013

View PDFchevron_right

35-mm film scanner as an intraoral dental radiograph digitizer II: Effects of brightness and contrast adjustments

Michael Vannier

1993

View PDFchevron_right

Radiological image presentation requires consideration of human adaptation characteristics

Mark F McEntee

Proceedings of SPIE - The International Society for Optical Engineering

View PDFchevron_right

Equalized contrast display processing for digital radiography

Ulrich Neitzel

Medical Imaging 2002: Visualization, Image-Guided Procedures, and Display, 2002

View PDFchevron_right

A Colour Contrast Assessment System: Design for People with Visual Impairment

David Wyatt

Designing Inclusive Interactions, 2010

View PDFchevron_right

Assessment of display performance for medical imaging systems: Executive summary of AAPM TG18 report

William Pavlicek

Medical Physics, 2005

View PDFchevron_right