Reference levels at European level for cardiac interventional procedures (original) (raw)


In diagnostic and interventional cardiology procedures performed with the use of X-ray diagnostic imaging systems, the long fluoroscopy time and the large number of cine projections, as well as the repetition of the procedure due to the recurrence of the lesion--a common event--result in a high locally delivered skin dose, which may even lead to patient skin necrosis. The purpose of this study was to collect information in order to estimate the patient dose during coronary angiography and coronary angioplasty procedures, using the dose-area product measuring system of the X-ray angiographic machine. Dose-area product (DAP), fluoroscopy time, number of sequences and frames per sequence were collected for each of 108 coronary angiography and 101 coronary angioplasty procedures, using the dedicated X-ray machine of the hospital's haemodynamic department, where more than 3000 procedures are performed per year. The median values of DAP were 19.96 and 40.17 Gy.cm(2) for coronary angio...

Introduction: The current regulations in Poland in the field of interventional radiology only include diagnostic reference levels (DRL) for five procedures, containing only two for cardiological (hemodynamic) procedures, and only for adults. Given the insufficient number of DRLs, the need to introduce local levels based on the intervention procedures performed was identified. The purpose of this research was the evaluation of radiation doses (DRL, effective dose) received by patients in cardiological interventional procedures. Material and methods: The DRL level was defined as the 75th percentile of the distribution of dosimetric parameters KAP and Kair,ref for each type of cardiological procedure. Data include three different X-ray units and 27 interventional cardiologists, derived from February 2019 to June 2019 and from August 2021 to December 2021. In order to estimate the effective dose, the appropriate conversion factors for cardiological procedures were used. The total number...

The objective of this study was to estimate the French national updated reference levels (RLs) for coronary angiography (CA) and percutaneous coronary intervention (PCI) by a dose audit from a large data set of unselected procedures and in standard-sized patients. Kerma-area product (PKA), air kerma at interventional point (Ka,r), fluoroscopy time (FT), and the number of registered frames (NFs) and runs (NRs) were collected from 51 229 CAs and 42 222 PCIs performed over a 12-month period at 61 French hospitals. RLs estimated by the 75th percentile in CAs and PCIs performed in unselected patients were 36 and 78 Gy.cm² for PKA, 498 and 1285 mGy for Ka,r, 6 and 15 min for FT, and 566 and 960 for NF, respectively. These values were consistent with the RLs calculated in standard-sized patients. The large difference in dose between sexes leads us to propose specific RLs in males and females. The results suggest a trend for a time-course reduction in RLs for interventional coronary procedu...