Intra- and Inter-Rater Reliability of Ultrasound in Plantar Fascia Thickness Measurement (original) (raw)

Clinical Utility of Ultrasound Measurements of Plantar Fascia Width and Cross-Sectional Area

Journal of the American Podiatric Medical Association, 2017

Background:We sought to develop a standardized protocol for ultrasound (US) measurements of plantar fascia (PF) width and cross-sectional area (CSA), which may serve as additional outcome variables during US examinations of both healthy asymptomatic PF and in plantar fasciopathy and determine its interrater and intrarater reliability.Methods:Ten healthy individuals (20 feet) were enrolled. Participants were assessed twice by two raters each to determine intrarater and interrater reliability. For each foot, three transverse scans of the central bundle of the PF were taken at its insertion at the medial calcaneal tubercle, identified in real time on the plantar surface of the foot, using a fine wire technique. Reliability was determined using intraclass correlation coefficients (ICC), standard errors of measurement (SEM), and limits of agreement (LOA) expressed as percentages of the mean. Reliability of PF width and CSA measurements was determined using PF width and CSA measurements f...

Application of ultrasound in the assessment of plantar fascia in patients with plantar fasciitis: a systematic review

Plantar fasciitis (PFS) is one of the most common causes of heel pain, estimated to affect 10% of the general population during their lifetime. Ultrasound (US) imaging technique is increasingly being used to assess plantar fascia (PF) thickness, monitor the effect of different interventions and guide therapeutic interventions in patients with PFS. The purpose of the present study was to systematically review previously published studies concerning the application of US in the assessment of PF in patients with PFS. A literature search was performed for the period 2000-2012 using the Science Direct, Scopus, PubMed, CINAHL, Medline, Embase and Springer databases. The key words used were: ultrasound, sonography, imaging techniques, ultrasonography, interventional ultrasonography, plantar fascia and plantar fasciitis. The literature search yielded 34 relevant studies. Sixteen studies evaluated the effect of different interventions on PF thickness in patients with PFS using US; 12 studies compared PF thickness between patients with and without PFS using US; 6 studies investigated the application of US as a guide for therapeutic intervention in patients with PFS. There were variations among studies in terms of methodology used. The results indicated that US can be considered a reliable imaging technique for assessing PF thickness, monitoring the effect of different interventions and guiding therapeutic interventions in patients with PFS.

Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity

Diagnostics (Basel, Switzerland), 2016

This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF ...

Sonographic measurement of normal plantar fascia thickness in healthy nepalese population

Journal of Manmohan Memorial Institute of Health Sciences, 2016

BACKGROUND: Plantar fascitis is one of the commonest causes of heel pain. Thickening of plantar fascia is the most consistent sonological finding in plantar fasciitis.Objective: To estimate normal plantar fascia thickness in healthy Nepalese volunteers and evaluate its relationship with age, sex, height, weight and body mass index (BMI).METHODS: The plantar fascia thickness was measured at 5mm distal to its insertion into the calcaneus using 10 MHz linear array transducer. Total 700 feet of 350 healthy volunteers were evaluated in our study. Physical examination was also performed to assess height, weight and BMI.RESULTS: The mean plantar fascia thickness among entire population, male subjects, female subjects, right side and left side were respectively 2.39±0.37 (Range 1.4-3.6; 95% confidence interval=2.36-2.42); 2.47±0.37 (Range 1.4-3.6; 95% confidence interval =2.43-2.51); 2.32±0.35 (Range 1.4-3.5; 95% confidence interval =2.28-2.36); 2.39±0.36 (Range 1.4-3.6; 95% confidence inte...

Evaluation of plantar fascia using high-resolution ultrasonography in clinically diagnosed cases of plantar fasciitis

Polish Journal of Radiology

The aim of this study was to assess the efficacy of high-resolution ultrasonography in the assessment of plantar fascia in individuals with heel pain, before and after treatment. Material and methods: This study was conducted from 2016 to 2019, during which time 44 clinically diagnosed patients of plantar fasciitis were compared to 50 normal volunteers. There were 25 males and 25 females in the control group and 42 females and two males in the study group. Thirty-eight patients had unilateral disease, and six patients had bilateral disease. The thickness of the plantar fascia was measured just anterior to its calcaneal attachment using ultrasonography. Body mass index (BMI) was also calculated in both groups. Results: The plantar fascia was 2-4 mm thick in the control group whereas it was > 4 mm thick in 48 heels in the study group. With cutoff of > 4 mm as diagnostic of plantar fasciitis, this study had a sensitivity of 96%, specificity of 100%, and accuracy of 98%. BMI was increased in 60% of female patients. All patients were treated with local infiltration of corticosteroid. In 37/42 patients (43 heels) who had improved clinically, the thickness of plantar fascia was reduced to < 4 mm when assessed after six weeks of corticosteroid injection. Conclusions: Diagnosis of plantar fasciitis can be easily verified by ultrasonography with plantar fascia thickness > 4 mm being suggestive of plantar fasciitis. Ultrasound can also be used to evaluate treatment response. Ultrasonography helps the clinician in confirming the diagnosis of plantar fasciitis and also in assessing the response to treatment.

Effect of gender, age and anthropometric variables on plantar fascia thickness at different locations in asymptomatic subjects

European Journal of Radiology, 2007

The study was aimed to investigate plantar fascia thickness at different locations in healthy asymptomatic subjects and its relationship to the following variables: weight, height, sex and age. Material and methods: The study evaluates 96 feet of healthy asymptomatic volunteers. The plantar fascia thickness was measured at four different locations: 1 cm proximal to the insertion of the plantar fascia, at the insertion of the plantar fascia on the calcaneus and separate out 1 cm + 2 cm distal to the insertion. A 10 MHz linear-array transducer was used. Results: There were statistically significant differences in plantar fascia thickness at the four different locations (p < 0.001) although no differences in PF thickness were found between the two distal from insertion locations (1 and 2 cm). Multiple regression analysis showed sex as independent predictor of plantar fascia thickness at 1 cm proximal to the insertion. At origin and 1 cm distal to insertion weight was an independent predictor of plantar fascia thickness. Conclusions: There are differences of thickness at different locations of plantar fascia measured by ultrasonography. Thickness at 1 cm proximal to the insertion is influenced by sex and thickness at origin and at 1 cm distal to the insertion has a direct relationship with body weight. This could be attributed to the overloading effect that weight has on plantar fascia in healthy symptomatic subjects at these two locations. Height and age did not seem to influence as independent variables in plantar fascia thickness among non-painful subjects.

Normal Plantar Fascia Thickness in Adult

MNJ (Malang Neurology Journal), 2022

Background: Plantar fasciitis is a common problem caused by thickening of the plantar fascia. The normal plantar fascia thickness ranged between 2-3 mm and it was generally accepted that value more than 4mm was considered pathologic. Objective: to identify normal plantar fascia thickness in adults using ultrasonography. Methods: This is a cross sectional study measuring the thickness of plantar fascia in 145 subjects with no history of heel pain. Plantar fascia thickness was measured in both feet using an ultrasound. Age, height and weight were recorded and analysed. Results: As much as 145 subjects were included in this study. Male to female ratio was 0.7. Mean age was 44 and body mass index (BMI) was mostly within normal range. Plantar fascia thickness in male was 2.71 ± 0.48 mm in right foot, and 2.74 ± 0.47 mm in left foot. Fascia thickness in female was 2.55 ± 0.50 mm in right foot, and 2.57 ± 0.45 mm in left foot. There was a significant plantar fascia thickness difference bet...

SONOELASTOGRAPHY OF PLANTAR FASCIA: REPRODUCIBILITY AND PATTERN DESCRIPTION IN HEALTHY SUBJECTS AND SYMPTOMATIC SUBJECTS

The purpose of the work reported here was to describe the sonoelastographic appearance of the plantar fascia of healthy volunteers and patients with fasciitis. Twenty-three healthy subjects and 21 patients with plantar fasciitis were examined using B-mode and real-time sonoelastography (RTSR) scanning. B-Mode examination included fascia thickness and echotexture. Echogenicity and echovariation of the color histogram were analyzed. Fasciae were classified into type 1, blue (more elastic); type 2, blue/green (intermediate); or type 3, green (less elastic). RTSE revealed 72.7% of fasciae as type 2, with no significant association with fasciitis (c 2 5 3.6, df 5 2, p 5 0.17). Quantitative analysis of the color histogram revealed a significantly greater intensity of green (mean 5 77.8, 95% confidence interval [CI] 5 71.9-83.6) and blue (mean 5 74.2, 95% CI 5 69.7-78.8) in healthy subjects. Echovariation of the color red was 33.4% higher in the fasciitis group than in the healthy group (95% CI 5 16.7-50.1). Sonoelastography with quantitative analysis of echovariation can be a useful tool for evaluation of plantar fascia pathology. (

Sonographic evaluation of plantar fasciitis and relation to body mass index

European Journal of Radiology, 2005

We have investigated the role of sonography in the diagnosis of plantar fasciitis. This study evaluates 39 patients with plantar fasciitis and control group of 22 healthy volunteers. The plantar fascia thickness was measured 5 mm distal to the insertion of the calcaneus of plantar aponeurosis. Qualitative parameters such as decreased echogenity, biconvexity, perifascial fluid and calcification of plantar fascia were also noted. Mean plantar fascia thickness was measured 2.9 mm in patients with unilateral heel pain, 2.2 mm for contralateral normal heel and 2.5mm for control group. There was a statistically significant difference between heel with plantar fasciitis, contralateral normal heel and control groups (p=0.009 and 0.0001, respectively). Mean body mass index was 28 kg/m(2) in patients with heel pain and 25 kg/m2 in control group. Body mass index measurements were significantly different between plantar fasciitis and control groups. We found reduced plantar fascia echogenity in 16 cases (41%), calcaneal spur in 20 cases (51%), biconvex appearance in two cases (5.1%) and perifascial fluid in one case (2.5%). We conclude that in patients with plantar fasciitis, ultrasound may detect relatively small differences in plantar fascia thickness even in clinically unequivocal plantar fasciitis.