In-line measurements of the physical and thermodynamic properties of single and multicomponent liquids (original) (raw)
Related papers
Microchannels for applications in liquid dosing and flow-rate measurement
Sensors and Actuators A-physical, 1997
To investigate the performance of microengineered fluid channels in liquid dosing applications, llow-rate mc,'tsurements have been l)erliwmed with various channel geometries in a range from 0.0l to 1000 ixl min-~. An optical flow-measurement technique has been developed to enhance the measurement range into the desired low flow range ( 10-3 to I ~1 rain-t), and is compared to a standard gravimetric method, which is preferably used for flow rates above 1 ~1 min-~. In addition, influences of the temperttture-dependent viscosity and effects arising from fluidmechanical characteristics are studied. These influences are also calculated from laminar llow theory and semi-empMcal models to obtain a theoretical model. It is found that the theoretical model is able to describe the measurement results well in the whole flow range. The model is implemented on a PC-based system, which measures the pressure drop across the microchannel and the fluid temperature and calculates the flow. In a temperature range from 20 to 50°C excellent agreement is l'ound. © 1997 Elsevier Science S.A.
A biodynamic microsystem for fluids viscosity measurements
Journal of Physics: Conference Series, 2006
The purpose of this research was to model, design and fabricate a biodynamic analysis microsystem required for determination of various molecular transport properties of the biological fluids. In order to achieve this, a lab-on-a-chip device was fabricated. The microfluidic system developed satisfies the objectives for the study of microcirculation and characterization of cell rheological properties, functions and behaviour. The measurement principle of the viscosity of biological fluids is based on the detection of the rotation of a polysilicon gear-wheels system. The gear-wheels have external diameters of 250 μm, 200 μm, 160 μm and 3 μm thickness. The micromachining process combines the undercut and refill technique with pin-joint bearing permitting the fabrication of bushings that were used to elevate the rotor away from the silicon surface. The testing of the microfluidic dynamic system was performed using electromagnetic micropumps and magnetic controllers. Each device was fabricated by silicon micromachining technology and tested to obtain the specific characteristics.
Simultaneous measurement of fluids density and viscosity using HP/HT capillary devices
The Journal of Supercritical Fluids, 2015
Accessing fluids thermophysical properties is crucial in chemical engineering for they are required in most of process parameter calculations. Nevertheless, these are not always available in the literature. In the present paper, we propose a fast and efficient microfluidic approach for simultaneously accessing density and viscosity of homogeneous fluids mixtures. In comparison with classical set-ups, microfluidic devices exhibit higher heat transfer capability and small volumes, resulting in an easy control of temperature, fast conditions screening and improved operation safety. A set-up was designed based on the subtraction of two pressures: capillary and bypass lines. The devices use a capillary system with a diameter of 73.6 m (±0.5%). The proposed set-up can work in a wide range of pressures (10 < P(bar) < 200) and temperatures (30 < T( • C) < 227). The developed strategy was applied to pure fluids (CO 2 and N 2 ), and to mixtures (CYC + CO 2 and CO 2 + H 2 ).
Microfluidic dynamic system for biological fluids viscosity measurements
CAS 2005 Proceedings. 2005 International Semiconductor Conference, 2005., 2005
The purpose of this research was to model, design and fabricate a microdynamic system, using a four masks silicon micromachining process and sacrificial layers technique. The measurement principle is the detection of the rotation of a micromachining polysilicon gear wheels system with external diameters of 250 µm, 200 µm, 160 µm and 3 µm thickness combine the undercut and refill technique with pin-joint bearing permitting the fabrication of bushings that can be used, for example, to elevate the rotor away from the silicon surface. The microfluidic dynamic system consists of a gear wheels system, an electromagnetic micropump and a magnetic controller. Each device is fabricated by silicon micromachining technology and tested to obtain the specific characteristics.
MFMET A2.3.2: Test protocols for liquid properties related to microfluidic devices
Zenodo (CERN European Organization for Nuclear Research), 2023
Test protocols for at least three liquid properties (such as density, viscosity and refractive index) related to microfluidic devices, and ensuring traceability to national standards and conformity to existing normative standards. www.mfmet.eu Establishing Metrology Standards in Microfluidic Devices This report was written as part of activity A2.3.2 from the EMPIR Establishing Metrology Standards in Microfluidic Devices (MFMET) project. The three-year European project commenced on 1 st June 2021 and focused on providing a generic methodology of accurate measurement of a particular quantity in a microfluidic device by utilising standardised methods and reference documents, e.g.
AN OPTICAL MICRO-FLUIDIC VISCOMETER
A new method for measuring viscosity relative to a reference fluid and applicable to a continuous process micro-fluidic device is presented. The measurement is based on the volume flow rate ratio and interface location between two co-flowing streams in a micro-fabricated T-channel and utilizes the inversion of a closedform solution for the velocity distribution in a rectangular channel. Neither absolute flow rates or pressure differences are required. Since optical detection is the basis for the measurement, the method lends itself to the measurement of intrinsic viscosity, which requires measurement of both absolute viscosity and concentration. Experimental verification of the method yielded measurements of absolute viscosity within two percent of standard methods for dilute aqueous dextran suspensions.
Zenodo (CERN European Organization for Nuclear Research), 2022
A2.3.1: Literature review of existing metrology and normative standards related to the liquid properties and microfluidic devices Work package 2 https://mfmet.eu Establishing Metrology Standards in Microfluidic Devices This report was written as part of activity 2.3.1 from the EMPIR Establishing Metrology Standards in Microfluidic Devices (MFMET) project. The three-year European project commenced on 1 st June 2021 and focused on providing a generic methodology of accurate measurement of a particular quantity in a microfluidic device by utilising standardised methods and reference documents, e.g.
Towards a continuous microfluidic rheometer
Microfluidics and Nanofluidics, 2008
In a previous paper we presented a way to measure the rheological properties of complex fluids on a microfluidic chip (Guillot et al., Langmuir 22:6438, 2006). The principle of our method is to use parallel flows between two immiscible fluids as a pressure sensor. In fact, in a such flow, both fluids flow side by side and the size occupied by each fluid stream depends only on both flow rates and on both viscosities. We use this property to measure the viscosity of one fluid knowing the viscosity of the other one, both flow rates and the relative size of both streams in a cross-section. We showed that using a less viscous fluid as a reference fluid allows to define a mean shear rate with a low standard deviation in the other fluid. This method allows us to measure the flow curve of a fluid with less than 250 lL of fluid. In this paper we implement this principle in a fully automated set up which controls the flow rate, analyzes the picture and calculates the mean shear rate and the viscosity of the studied fluid. We present results obtained for Newtonian fluids and complex fluids using this set up and we compare our data with cone and plate rheometer measurements. By adding a mixing stage in the fluidic network we show how this set up can be used to characterize in a continuous way the evolution of the rheological properties as a function of the formulation composition. We illustrate this by measuring the rheological curve of four formulations of polyethylene oxide solution with only 1.3 mL of concentrated polyethylene oxide solution. This method could be very useful in screening processes where the viscosity range and the behavior of the fluid to an applied stress must be evaluated.