Is cervical length evaluated by transvaginal ultrasonography helpful in detecting true preterm labor? (original) (raw)

Prediction of Preterm Delivery by Assessment of Cervical Length Using Transvaginal Ultrasound

gauri shinde

Journal of Evolution of Medical and Dental Sciences, 2015

View PDFchevron_right

F88The value of cervical length measurement in the prediction of preterm delivery prior to 34 weeks gestation in women presenting with threatened preterm labour

A. Tekay

Ultrasound in Obstetrics & Gynecology, 2002

View PDFchevron_right

Selective use of sonographic cervical length measurement for predicting imminent preterm delivery in women with preterm labor and intact membranes

G. Kayem

Ultrasound in Obstetrics and Gynecology, 2008

View PDFchevron_right

Transvaginal cervical length measurement for prediction of preterm birth in women with threatened preterm labor: a meta-analysis

Stefania Papatheodorou

Ultrasound in Obstetrics and Gynecology, 2010

View PDFchevron_right

Ultrasonographic Cervical Length Measurement at 10-14-and 20-24-weeks' Gestation and Prediction of Preterm Delivery

IJAERS Journal

View PDFchevron_right

A prospective study of prediction of preterm delivery by cervical assessment by transvaginal sonography

Jaiswal Kavita

Indian Journal of Obstetrics and Gynecology Research

View PDFchevron_right

Role of cervical length evaluation with transvaginal ultrasound for prediction of preterm delivery in low risk pregnancy

Subhash Mudanur

International Journal of Reproduction, Contraception, Obstetrics and Gynecology, 2018

View PDFchevron_right

A comparison of the predictive value of transvaginal cervical length at 11‐14 weeks and at 18‐22 weeks of gestation in preterm labour

IP Innovative Publication Pvt. Ltd.

View PDFchevron_right

Significance of ultrasound vaginal cervicometry in predicting preterm delivery

Pavel Calda

2002

View PDFchevron_right

Predicting preterm labour by cervical length measurement

vinita sarbhai

International Journal of Reproduction, Contraception, Obstetrics and Gynecology, 2016

View PDFchevron_right

Sonographic cervical length in singleton pregnancies with intact membranes presenting with threatened preterm labor

Joachim Dudenhausen

Ultrasound in Obstetrics and Gynecology, 2004

View PDFchevron_right

Sonographic measurement of cervical length in threatened preterm labor with intact membranes

Jorge Carrillo

American Journal of Obstetrics and Gynecology, 2006

View PDFchevron_right

A study of cervical length measured ultrasonographically in prediction of preterm delivery

Pooja Pooja

Obsgyne Review: Journal of Obstetric and Gynecology, 2017

View PDFchevron_right

Ultrasound assessment of cervical length in threatened preterm labor

Akmal Akmal

Ultrasound in Obstetrics & Gynecology, 2003

View PDFchevron_right

The Impact of Routine Transvaginal Ultrasound Measurement of the Cervical Length on the Prediction of Preterm Birth: A Retrospective Study in a Tertiary Hospital

Alexandra Matias

Revista Brasileira de Ginecologia e Obstetrícia / RBGO Gynecology and Obstetrics, 2021

View PDFchevron_right

Transvaginal Ultrasound Assessment of Cervical Length in Threatened Preterm Labor

Azhari Azhari

Indonesian Journal of Obstetrics and Gynecology, 2020

View PDFchevron_right

Second trimester cervical length measurement for prediction spontaneous preterm birth in an unselected risk population

Alberto Peixoto

Obstetrics & Gynecology Science, 2017

View PDFchevron_right

A comparison of sonographic cervical parameters in predicting spontaneous preterm birth in high-risk singleton gestations

Anthony Vintzileos

Ultrasound in Obstetrics and Gynecology, 2001

View PDFchevron_right

Preterm labor diagnosis by sonographic measurement of the uterine cervical length

Hilton Koch

Radiologia …, 2009

View PDFchevron_right

To Evaluate Efficacy of Sonographic Cervical Length to Predict Preterm Labour

punya pratap singh

Annals of International Medical and Dental Research, 2016

View PDFchevron_right

Cervical length measurement by transvaginal sonography in predicting preterm labour in low risk women

jayamol anilkumar

International Journal of Reproduction, Contraception, Obstetrics and Gynecology, 2017

View PDFchevron_right

Cervical Assessment by Ultrasound for Preventing Preterm Delivery

Jason Baxter

Obstetrics & Gynecology, 2009

View PDFchevron_right

Study of Predictive Value of Transvaginal Sonographic Cervical Length Measurement in Preterm Labour

IOSR Journals

View PDFchevron_right

To Study the efficacy of Digital and Transvaginal Ultrasonographic measurement of cervical length in asymptomatic high risk women at POG 16-24 weeks as a predictor of preterm delivery and progesterone and cerclage vs Progestrone alone for short cervical length in prevention of Preterm labour

Dr Santosh Minhas

International Journal of Reproduction, Contraception, Obstetrics and Gynecology, 2015

View PDFchevron_right

Predicting mode of delivery using mid-pregnancy ultrasonographic measurement of cervical length

OUJ Umeora

Nigerian Journal of Clinical Practice, 2012

View PDFchevron_right

Transvaginal Ultrasonographic Measurement of Cervical Length as a Predictor of Preterm Birth

Mishka Terplan

Ultrasound Quarterly, 2010

View PDFchevron_right

Prediction of the outcome of labour induction at term by transvaginal ultrasound in supine and upright position

Gha Fur

Zeitschrift Fur Geburtshilfe Und Neonatologie, 2007

View PDFchevron_right

Prediction of Preterm Birth: Nonsonographic Cervical Methods

Michael Ross

Seminars in Perinatology, 2009

View PDFchevron_right

Screening of preterm labor in Yazd city: transvaginal ultrasound assessment of the length of cervix in the second trimester Corresponding Author

Hosseinmolavi Vardanjani

View PDFchevron_right

Progressive Cervical Length Changes versus Single Cervical Length Measurement by Transvaginal Ultrasound for Prediction of Preterm Delivery

umut dilek

Gynecologic and Obstetric Investigation, 2007

View PDFchevron_right

Transvaginal sonographic measurement of cervical length to predict preterm birth in asymptomatic women at increased risk: a systematic review

Ibrahim A Abdelazim

Ultrasound in Obstetrics and Gynecology, 2008

View PDFchevron_right

Cervical Index: A Novel Sonographic ScreeningTest to Predict Preterm Birth

Lali Sichinava

EC Gynaecology, 2021

View PDFchevron_right

The importance of the transabdominal cervical length measurement to predict preterm delivery in low-risk pregnant women for premature birth

Çiğdem Kunt İşgüder

SiSli Etfal Hastanesi Tip Bulteni / The Medical Bulletin of Sisli Hospital, 2016

View PDFchevron_right

The use of a variable cut-off value of cervical length in women admitted for preterm labor before and after 32 weeks

Olga Gómez

Ultrasound in Obstetrics & Gynecology, 2007

View PDFchevron_right

Cervical assessment at 22 and 27 weeks for the prediction of spontaneous birth before 34 weeks in twin pregnancies: is transvaginal sonography more accurate than digital examination?

Philippe Descamps

Ultrasound in Obstetrics and Gynecology, 2005

View PDFchevron_right