Is cervical length evaluated by transvaginal ultrasonography helpful in detecting true preterm labor? (original) (raw)
Prediction of Preterm Delivery by Assessment of Cervical Length Using Transvaginal Ultrasound
gauri shinde
Journal of Evolution of Medical and Dental Sciences, 2015
View PDFchevron_right
F88The value of cervical length measurement in the prediction of preterm delivery prior to 34 weeks gestation in women presenting with threatened preterm labour
A. Tekay
Ultrasound in Obstetrics & Gynecology, 2002
View PDFchevron_right
Selective use of sonographic cervical length measurement for predicting imminent preterm delivery in women with preterm labor and intact membranes
G. Kayem
Ultrasound in Obstetrics and Gynecology, 2008
View PDFchevron_right
Transvaginal cervical length measurement for prediction of preterm birth in women with threatened preterm labor: a meta-analysis
Stefania Papatheodorou
Ultrasound in Obstetrics and Gynecology, 2010
View PDFchevron_right
Ultrasonographic Cervical Length Measurement at 10-14-and 20-24-weeks' Gestation and Prediction of Preterm Delivery
IJAERS Journal
View PDFchevron_right
A prospective study of prediction of preterm delivery by cervical assessment by transvaginal sonography
Jaiswal Kavita
Indian Journal of Obstetrics and Gynecology Research
View PDFchevron_right
Role of cervical length evaluation with transvaginal ultrasound for prediction of preterm delivery in low risk pregnancy
Subhash Mudanur
International Journal of Reproduction, Contraception, Obstetrics and Gynecology, 2018
View PDFchevron_right
A comparison of the predictive value of transvaginal cervical length at 11‐14 weeks and at 18‐22 weeks of gestation in preterm labour
IP Innovative Publication Pvt. Ltd.
View PDFchevron_right
Significance of ultrasound vaginal cervicometry in predicting preterm delivery
Pavel Calda
2002
View PDFchevron_right
Predicting preterm labour by cervical length measurement
vinita sarbhai
International Journal of Reproduction, Contraception, Obstetrics and Gynecology, 2016
View PDFchevron_right
Sonographic cervical length in singleton pregnancies with intact membranes presenting with threatened preterm labor
Joachim Dudenhausen
Ultrasound in Obstetrics and Gynecology, 2004
View PDFchevron_right
Sonographic measurement of cervical length in threatened preterm labor with intact membranes
Jorge Carrillo
American Journal of Obstetrics and Gynecology, 2006
View PDFchevron_right
A study of cervical length measured ultrasonographically in prediction of preterm delivery
Pooja Pooja
Obsgyne Review: Journal of Obstetric and Gynecology, 2017
View PDFchevron_right
Ultrasound assessment of cervical length in threatened preterm labor
Akmal Akmal
Ultrasound in Obstetrics & Gynecology, 2003
View PDFchevron_right
The Impact of Routine Transvaginal Ultrasound Measurement of the Cervical Length on the Prediction of Preterm Birth: A Retrospective Study in a Tertiary Hospital
Alexandra Matias
Revista Brasileira de Ginecologia e Obstetrícia / RBGO Gynecology and Obstetrics, 2021
View PDFchevron_right
Transvaginal Ultrasound Assessment of Cervical Length in Threatened Preterm Labor
Azhari Azhari
Indonesian Journal of Obstetrics and Gynecology, 2020
View PDFchevron_right
Second trimester cervical length measurement for prediction spontaneous preterm birth in an unselected risk population
Alberto Peixoto
Obstetrics & Gynecology Science, 2017
View PDFchevron_right
A comparison of sonographic cervical parameters in predicting spontaneous preterm birth in high-risk singleton gestations
Anthony Vintzileos
Ultrasound in Obstetrics and Gynecology, 2001
View PDFchevron_right
Preterm labor diagnosis by sonographic measurement of the uterine cervical length
Hilton Koch
Radiologia …, 2009
View PDFchevron_right
To Evaluate Efficacy of Sonographic Cervical Length to Predict Preterm Labour
punya pratap singh
Annals of International Medical and Dental Research, 2016
View PDFchevron_right
Cervical length measurement by transvaginal sonography in predicting preterm labour in low risk women
jayamol anilkumar
International Journal of Reproduction, Contraception, Obstetrics and Gynecology, 2017
View PDFchevron_right
Cervical Assessment by Ultrasound for Preventing Preterm Delivery
Jason Baxter
Obstetrics & Gynecology, 2009
View PDFchevron_right
Study of Predictive Value of Transvaginal Sonographic Cervical Length Measurement in Preterm Labour
IOSR Journals
View PDFchevron_right
To Study the efficacy of Digital and Transvaginal Ultrasonographic measurement of cervical length in asymptomatic high risk women at POG 16-24 weeks as a predictor of preterm delivery and progesterone and cerclage vs Progestrone alone for short cervical length in prevention of Preterm labour
Dr Santosh Minhas
International Journal of Reproduction, Contraception, Obstetrics and Gynecology, 2015
View PDFchevron_right
Predicting mode of delivery using mid-pregnancy ultrasonographic measurement of cervical length
OUJ Umeora
Nigerian Journal of Clinical Practice, 2012
View PDFchevron_right
Transvaginal Ultrasonographic Measurement of Cervical Length as a Predictor of Preterm Birth
Mishka Terplan
Ultrasound Quarterly, 2010
View PDFchevron_right
Prediction of the outcome of labour induction at term by transvaginal ultrasound in supine and upright position
Gha Fur
Zeitschrift Fur Geburtshilfe Und Neonatologie, 2007
View PDFchevron_right
Prediction of Preterm Birth: Nonsonographic Cervical Methods
Michael Ross
Seminars in Perinatology, 2009
View PDFchevron_right
Screening of preterm labor in Yazd city: transvaginal ultrasound assessment of the length of cervix in the second trimester Corresponding Author
Hosseinmolavi Vardanjani
View PDFchevron_right
Progressive Cervical Length Changes versus Single Cervical Length Measurement by Transvaginal Ultrasound for Prediction of Preterm Delivery
umut dilek
Gynecologic and Obstetric Investigation, 2007
View PDFchevron_right
Transvaginal sonographic measurement of cervical length to predict preterm birth in asymptomatic women at increased risk: a systematic review
Ibrahim A Abdelazim
Ultrasound in Obstetrics and Gynecology, 2008
View PDFchevron_right
Cervical Index: A Novel Sonographic ScreeningTest to Predict Preterm Birth
Lali Sichinava
EC Gynaecology, 2021
View PDFchevron_right
The importance of the transabdominal cervical length measurement to predict preterm delivery in low-risk pregnant women for premature birth
Çiğdem Kunt İşgüder
SiSli Etfal Hastanesi Tip Bulteni / The Medical Bulletin of Sisli Hospital, 2016
View PDFchevron_right
The use of a variable cut-off value of cervical length in women admitted for preterm labor before and after 32 weeks
Olga Gómez
Ultrasound in Obstetrics & Gynecology, 2007
View PDFchevron_right
Cervical assessment at 22 and 27 weeks for the prediction of spontaneous birth before 34 weeks in twin pregnancies: is transvaginal sonography more accurate than digital examination?
Philippe Descamps
Ultrasound in Obstetrics and Gynecology, 2005
View PDFchevron_right