Evaluation of various adaptive voltage positioning (AVP) schemes for computer power sources (original) (raw)
Related papers
Modeling and Design for a Novel Adaptive Voltage Positioning (AVP) Scheme for Multiphase VRMs
IEEE Transactions on Power Electronics, 2008
Adaptive voltage positioning (AVP) has been used in multiphase voltage regulator module (VRM) applications. A novel scheme, called AVP+, is analyzed in this paper. Small signal model is used to look into the control performance issues such as output impedance and stability. The model has been verified in the experiments and simulations. Compared to a conventional AVP schemes, the present scheme provides better stability margin and outputimpedance performance. This is especially true for the prevailing trend of using ceramic output capacitors and high switching frequency. The focus of the present paper is the small-signal modeling for control loop design using the AVP+ scheme which was never analyzed before. And the comparisons were made between AVP+ and AVP on the stability and output impedance performance.
Control strategy for hardware simplification of voltage source converter-based power applications
IET Power Electronics, 2011
A hardware simplification control strategy for three-phase voltage-source-converter-based power applications is presented. The main goal of the proposal is to reduce the number of sensors needed to implement the controller while maintaining the high performance of the system. To this end, ac-voltage and dc-current sensors are replaced by software sensors based on state observers. Consequently, a more rugged, smaller and cheaper realisation can be accomplished. Regarding the voltage source converter controller, an energy function and the reactive power of the converter are considered as outputs for constructing a feedback law based on the feedback linearisation technique. In this way, internal dynamics is avoided. In order to improve controller performance, estimates of the load power and its time derivative are feedforwarded. The ac-voltages and load power estimates are obtained by designing a reduced-order nonlinear observer. Several tests, with a realistic voltage source converter model that takes into account the switching power devices, validate the proposed technique. They evaluate the system performance in the presence of parameter uncertainties and disturbances in the AC input voltage.
International Journal on Electrical Engineering and Informatics, 2013
This paper investigates the effects of the DC link voltage of a voltage source converter (VSC)on the performance oftwo current control strategies of the VSCsfrom point of views: capability of tracking the references signals with a zero steady-state error and imposing less transients during the step changes in the references signals of the controllers. Two conventional and multivariable proportional-integral (PI) based dqcurrent controllerstrategy has been represented. Then based on the considering the worst step changes in the references signals of the VSC while the DC link voltage (V dc) is varying, a specified range has been obtained for theV dc .It has been depicted thatthe multivariable control strategy has less transient and more decoupling capability between d and q axis components of the current during the step changes which have been occurred in the various DC link voltage of the VSC. Alsofor tracking the reference signals,V dc of the inverter must be in a particular range.Otherwise tracking the reference signals verifies that the axes are not fully decoupled or in some cases the system would be unstable.
Adaptive two-loop Voltage-mode control of DC-DC switching converters
IEEE Transactions on Industrial Electronics, 2000
A new two-loop control scheme for voltage-mode control (VMC) of dc-dc switching converters is presented. The proposed method adds a high-gain robust loop with two controllers to the conventional VMC loop, achieving an analog "adaptive" loop in which the "equivalent voltage regulator" varies with the changing power stage parameters given as follows: 1) input voltage; 2) load; and 3) component tolerances. The loop significantly improves the disturbance rejection of the control system, i.e., closed-loop output impedance and audiosusceptibility while preserving the stability and the loop gain crossover frequency to a significant extent. Both the small-signal analysis and the experimental results carried out on a buck converter demonstrate the superiority of the proposed scheme with respect to the conventional single loop.
An efficient digital sliding controller for adaptive power-supply regulation
IEEE Journal of Solid-State Circuits, 2002
We propose a digital controller for adaptive power-supply regulation that uses sliding control, which is a widely used technique in switching power supplies for its fast transient response and robust stability. A novel reformulation of the sliding control law enables a simple and power-efficient digital implementation. The reference circuit can be either a delay line or a ring oscillator, and the sensor circuits for both cases are discussed. The prototype chip fabricated in 0.25-m CMOS technology demonstrates a power efficiency of 89%-95% over the regulated voltage range of 1.1-2.3 V.
Digital control strategies for switch-mode power supply
IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics, 2006
Analogue control of monolithic DC/DC converters is coming to a limit due to high switching frequency and a request for large regulation bandwidth. Digital control is now experimented for low-power low-voltage switch-mode power supply. Digital implementation of analogue solutions does not prove real performances. Other digital controllers have been experimented but applied to discrete converters. This paper compares a classical digital controller to a possible alternative strategy. Sensitivity functions are used to compare controller performances. RST algorithm determined by robust pole assignment shows better performances.
Adaptive Output Current FeedforwardControl in VR Applications
IEEE Transactions on Power Electronics, 2000
A method for adapting the gain of an output current feedforward path in VR applications is presented. For regulators using adaptive voltage positioning (AVP), output current feedforward can improve the dynamic response to fast load transients. However, the feedforward path depends on parameters of the power train that are not known with precision. By analyzing the error voltage and finding its correlation with the parameter error, a gradient algorithm is derived that makes the parameter error vanish and minimizes the voltage error.
Minimum Deviation Digital Controller IC for Single and Two Phase DC-DC Switch-Mode Power Supplies
2010
A digital PWM voltage mode controller integrated circuit (IC) for high-frequency dc-dc switching converters achieving virtually minimum possible, i.e. optimum, output voltage deviation to load transients is introduced. The IC is implemented with simple hardware, requiring small silicon area, and can operate as a single-phase or a two-phase controller. To minimize the area and eliminate known mode transition problems of the optimal response controllers, two novel blocks are combined. Namely, an asynchronous track-and-hold analogto-digital converter (ADC) and a "large-small" signal compensator are implemented. The ADC utilizes a pre-amplifier and only four comparators having approximately eight times smaller silicon area and power consumption than an equivalent windowed flash architecture. The "large-small" signal compensator consists of two parts, a digital PID minimizing small variations and a zero-current detection-based compensator suppressing large load transients. The large-signal compensator requires no extra calculations and has a low sensitivity to parameter variations. It utilizes a synchronization algorithm and the PID calculation results to obtain a bumpless mode transition and stable response to successive load transients. The IC occupying only 0.26 mm 2 silicon area is implemented in a CMOS 0.18µm process and its minimum deviation response is verified with a single and dual-phase 12 V-to-1.8 V, 500 kHz 60/120 W buck converter.
Design and implementation of PC-based high performance automatic voltage regulator
This paper presents an overview of the currently employed AVRs (Automatic Voltage Regulators), the analogue and the digital, microprocessor based sampled data controlled, devices with respect to their control systems. The main design aims and constraints are examined in terms of performance specification concerning the speed, accuracy and stability of control. The contradiction between transient and dynamic stability requirements and its present day resolution by introducing Power System Stabilizing function into the AVR functions is explained. The design is implemented and tested on a 110 W synchronous generator in Power System Laboratory with an IBM personal computer acting as the real time controller. The results show that the proposed PC-based AVR are very effective for operation of a controller. These include its low cost, fast response, higher reliability and ruggedness.
Hardware efficient digital auto-tuning average current-mode controller
2017 IEEE 18th Workshop on Control and Modeling for Power Electronics (COMPEL), 2017
This paper introduces a new hardware efficient auto tuning for digitally controlled average current-mode (ACM) controllers. The auto-tuning procedure extracts the required coefficients of the ACM controller to achieve tight voltage regulation as well as closed-loop dynamic performance that may be defined by the end-user. System stability is facilitated for wide operation range under parameters uncertainties and other variations. It is found that information of the change in the state-variables suffice for a successful and accurate closed-loop operation without the need of a detailed extraction of the values of the passive components. The algorithm is applicable upon power up of the SMPS and has been integrated into the soft-start routine of the converter, assuring tight and stable regulation of the output voltage under all scenarios. The effectiveness of the new digital auto-tuning ACM controller is demonstrated on an experimental 500kHz, 12V-to-1.2V digitally controlled synchronous buck converter.