Response of Laterally Loaded Rectangular and Circular Piles in Soils with Properties Varying with Depth (original) (raw)
Related papers
Drilled displacement piles – current practice and design
Drilled displacement piles are being increasingly used as foundation elements, particularly in projects requiring fast construction. Different types of drilled displacement (DD) piles are available in practice. DD piles are classified according to the drilling tool design and installation method. The capacity of a DD pile, depending on its type, is between the capacities of geometrically similar nondisplacement and full-displacement piles installed in the same soil profile. This paper provides an overview of the different types of DD piles and their installation techniques and describes three design methods used in practice. It also compares DD pile capacities obtained with these design methods for two different sites.
Practical Considerations for Design and Installation of Drilled Displacement Piles
Contemporary Topics in Deep Foundations, 2009
A design methodology for the capacity of Drilled Displacement (DD) piles was presented at the International Deep Foundation Congress in 2002. Advances in final design / installation developed since then were incorporated into a DD pile program for two large hotels in Orange County, Florida. The site consisted of granular soils to about 15-m (50-ft) depth underlain by inter-bedded coarse and fine-grained soils. The original design called for 457-mm (18-in) diameter by 29.3-m (96-ft) long conventional auger cast piles. It was estimated that 457-mm (18in) DD piles installed in the granular materials within the upper 15 m (50 ft) would more efficiently support the proposed loads. The project team elected to utilize DD piles at a substantial cost savings. This paper focuses on one of the two hotel areas. The conditions and construction methods are applicable to both hotel sites.
Performance of Drilled Displacement Piles in the Midwestern United States
2010
Drilled displacement (DD) piles often develop significantly larger unit shaft resistance values than other drilled or augered pile systems in coarse grained materials. Minimal vibration and limited spoil development are also associated with DD pile installation and these factors are frequently additional financial and/or environmental benefits of the system. The application of DD piles in North America dates to the mid-1990s and their use in the Midwestern United States has been significant, particularly in the past 10 years.
Ground Improvement Resulting from Installation of Drilled Displacement Piles
2007
Drilled displacement piles (also known as augered cast-in-place displacement piles or augured, pressure grouted displacement piles) are installed by the displacement of soil and subsequent placement of fluid cement grout within the evacuated volume. Depending on the soil grain-size characteristics, soil behavior, in situ soil density, pile spacing, and pile diameter, the installation process can result in measurable densification and an increase in lateral stress. This paper examines the conditions prior to and following the installation of drilled displacement piles at sandy sites using the cone penetration test. The data support that the installation of drilled displacement piles results in a substantial increase in tip resistance.
Effect of Embedded Length on Laterally Loaded Capacity of Pile Foundation
2019
In the analysis of soil-pile interaction under lateral load, the effect of the embedded length of a pile is an important parameter which has a significant influence on its lateral load capacity. This paper investigates the effect of embedded length of a single pile on its ultimate lateral load capacity. In this research, a 30mm steel rod pile was used, and four embedment lengths were selected (250, 300, 350, and 400 mm) for embedment ratios (length to diameter, L/D) = 8.3, 10, 11.7 and 13.3, respectively. The pile was embedded in three different relative densities of sand (loose, medium, and dense). The tests were performed using constant rate displacement method. The results indicate that there is an increase in the capacity of laterally loaded pile up to 247% when embedded ratio (L/D) increases from 8.3 to 13.3 and when the relative density increases from 12% to 85% there is an increase up to 599% in the resistant capacity of the pile.
Geotechnical and construction considerations of pile foundations in problematical soils
Japanese Geotechnical Society Special Publication, 2016
The Continuous Flight Auger (CFA) technology has evolved especially in recent decades. Using of CFA technology has expanded all over the world. The article deals with geotechnical design of pile foundations, especially by static load tests and by calculation using numerical models. Results of static load tests which were performed in and in Slovakia are analysed and compared with numerical modelling. The technology of CFA has been used due to the advantages of this technology in comparison with driven and bored piles in local geotechnical conditions. Plaxis 2011 was used for CFA piles analyses by FEM. Advanced constitutive hardening soil model was used for soil layers. Comparison of load-settlement curves, ratio of pile base and pile shaft resistance and distribution of unit shaft friction are presented in the paper. The best geoengineering solution in this case is the use of new pile technology CFA (continuous flight auger), FDP (full displacement piles), DDS (drilling displacement system), that lead to increased bearing capacity.
Recent advances in the design of axially-loaded piles in sandy soils
The research performed in the last decade at Purdue University on the vertical load response and design of piles (particularly drilled shafts and pipe piles) is reviewed. Both numerical and experimental investigations were performed, and values for unit base and shaft resistance normalized with respect to cone resistance are proposed for design. The study takes into account the loading processes associated with the pile installation, and the corresponding alteration of soil properties that affect the pile response. The normalized unit resistances are provided for a relative settlement of 10%, which is widely used as a design criterion. A strong dependence of the normalized unit resistances on relative density has been observed and the suggested values account for the effect. Thus, the proposed normalized unit resistances account for the soil state and the loading processes, and can be used in design. Results with respect to IFR and PLR are provided as well, for open-ended piles.
IOP Conference Series: Earth and Environmental Science, 2021
Deep foundations are essential for the soft soil deposits that are ubiquitous in the Nordic countries. Precast driven displacement piles are commonly used, due to the ease of installation and their low cost. The stiffness and strength of the clay surrounding the piles will change during and after the pile installation process. This paper presents an effective stress based numerical framework that elaborates the pile set-up and pile ageing mechanisms observed empirically. For the trial case studied, it is demonstrated that the magnitude of the increase in axial bearing capacity over time is strongly linked to the pile installation stage. Furthermore, it is found that classic effective stress based soil mechanics concepts readily describe the observed behaviour.
Enhancement of The Behaviour of Laterally Loaded Vertical Piles Embedded in Clayey Soil
Journal of Engineering Research, 2019
One of the most important problems is the construction on a soft clay soil, which extends over many areas in Egypt, Construction on a soft clay soil requires the use of deep foundations. In most of the cases the pile lateral capacity isn't satisfied due to the upper soft clay layers. Thus, there is a need to enhance the lateral load behavior of the pile. This paper is to study the enhancement of the lateral behavior of piles by replacing the upper layers of soft clay with dense sand. A series of laboratory tests were conducted on a single pile in soft clay soil. The upper clay layer around the pile was removed and replaced with compacted dense sand and the tests were repeated. The model pile used in this study was made of smooth hollow steel pipe. The outer diameter and wall thickness were 21 and 1.8 mm, respectively. Results indicated that the improvement of laterally loaded pile behavior was found to be strongly dependent on the replaced layer depth and replaced layer extension around the pile in dense sand. Results of experimental investigations were used to extract the lateral load-lateral displacement (P-∆) curves.