Implantable and Semi-Implantable Hearing Aids: A Review of History, Indications, and Surgery (original) (raw)
2014, International Archives of Otorhinolaryngology
AI-generated Abstract
This review paper presents an overview of implantable and semi-implantable hearing aids, highlighting their historical development, current indications, and surgical approaches. Key devices discussed include the Vibrant Soundbridge (VSB) and the Esteem system, detailing their components, mechanisms, and the audiologic criteria required for patient candidacy. Emphasis is placed on the advancements in the field and the surgical techniques necessary for implantation, along with considerations related to patient anatomy and specific types of hearing loss.
Related papers
Applied Acoustics, 2013
A non-surgical, direct driving hearing device with an actuator placed on the tympanic membrane was designed, fabricated and tested. The actuator consisted of two photodiodes, an aluminum ring, two neodymium iron permanent magnets, two opposing wound coils, a latex membrane and a Provil Novo™ membrane. The transducer coupled to the ear drum-utilizing photodiodes and permanent magnets on the motive components could eliminate the need for electrical connections to the moving components. An optic probe was designed to allow sound and light signals to enter the ear canal. By using opto-electromagnetic coupling, the developed hearing device could transmit information over a distance without using cables. The wireless actuator was achieved by two configurations: in one, two light emitting diodes were used for carrying the input signals, and in the other, the corresponding photodiodes were used for receiving the light signals and generating the currents in the actuator. The wireless actuator was designed to use light to carry energy and transmit the signals; thus, the occlusion effect created by traditional ear molds could be avoided. Finally, the wireless actuator was fabricated and tested with a laser Doppler vibrometer. The actuator showed displacements of vibration between 30-0.2 nm and from 400 Hz to 7 kHz with reduced vibration at higher frequencies. The gain of the actuator with 120 lA on the umbo displacement was approximately 3-13 dB from 400 to1500 Hz and decreased to 6 dB between 1500 Hz to 3 kHz and down to À1 to À6 dB above 3 kHz. Distortions of the umbo vibration amplitude were approximately À1 to À10 dB across frequencies. The results suggest that light can transmit the sound signal remotely and that adequate amplification can be achieved by this actuator. The reduced amplitude above 3 kHz was a consequence of the mass effect of the actuator, which should be miniaturized in the future.
The floating mass transducer at the round window: Direct transmission or bone conduction?
Hearing Research, 2010
The round window placement of a floating mass transducer (FMT) is a new approach for coupling an implantable hearing system to the cochlea. We evaluated the vibration transfer to the cochlear fluids of an FMT placed at the round window (rwFMT) with special attention to the role of bone conduction. A posterior tympanotomy was performed on eleven ears of seven human whole head specimens. Several rwFMT setups were examined using laser Doppler vibrometry measurements at the stapes and the promontory. In three ears, the vibrations of a bone anchored hearing aid (BAHA) and an FMT fixed to the promontory (pFMT) were compared to explore the role of bone conduction. Vibration transmission to the measuring point at the stapes was best when the rwFMT was perpendicularly placed in the round window and underlayed with connective tissue. Fixation of the rwFMT to the round window exhibited significantly lower vibration transmission. Although measurable, bone conduction from the pFMT was much lower than that of the BAHA. Our results suggest that the rwFMT does not act as a small bone anchored hearing aid, but instead, acts as a direct vibratory stimulator of the round window membrane.
IJERT-Sound Bite Hearing System for Hearing Impairment
International Journal of Engineering Research and Technology (IJERT), 2019
https://www.ijert.org/Sound-Bite-Hearing-System-for-Hearing-Impairment https://www.ijert.org/research/sound-bite-hearing-system-for-hearing-impairment-IJERTCONV7IS02041.pdf Human ear is an organ of hearing in which the environmental sound is channeled to auditory meatus. Any obstruction in this mechanism results in hearing impairments. This may occur at birth or by the dysfunction of auditory nerve which cannot be improved surgically. This project aims to develop a non-invasive bone conduction device for those with problems in their various parts of ear. It transfers sound at the frequency of 20HZ-20kHZ by bone vibration directly to the cochlea thus bypassing the outer or middle ear and used for some hearing losses. The "SoundBite Hearing System" is developed for people with hearing disabilities like unilateral deafness and CHL. A simulation of hearing sound has been done through the LabVIEW. Bone conduction included provide a hearing support to the patient. In addition the system has a facility for mobile communication which is focused on coherent hearing. Here the signal processing strategy is adopted for restoration of cross-channel suppression in hearing impaired listeners. The input voice from the microphone is given simultaneously to the speaker and motor. Thereupon the sound travel to input mic tool which pick up the sound, converge the waves and convert them to useful data. This data is used in a wave form generator to plot the graph with respect to amplitude and time with a frequency of 1kHZ. This project concentrates on various emotions like anger, joy etc. This device is sure to help the people to communicate effectively both in direct conversation and mobile communication.
The linear velocity transducer is based upon the Faraday and Lenz induction laws. A permanent magnet is attached to the object being measured, and it is forced to pass through a fixed geometry coil. The magnet induces a voltage, which is proportional to the relative velocity of the magnet moving through the coil. It is used to measure velocity of low range movements, because of the practical lengths of the coils.
Auris Nasus Larynx, 2009
To demonstrate the safety and efficacy of the Otologics Carina Middle Ear Transducer for treatment of mixed hearing loss through a case report. A Carina fully implantable device with the MET transducer for conductive applications was implanted in a 48-year-old woman suffering from right mixed hearing loss (mean PTA loss: 80 dB). A facial recess approach was used to access the middle ear. Sclerotic tissue obliterated the stapes footplate so the approach selected was to place the transducer directly on the round window. The mounting bracket was placed on the mastoid and the prosthesis was advanced toward the round window until the Otologics surgical software indicated contact. Effective stimulation of the cochlea was confirmed intraoperatively by ABR monitoring. Postoperative unaided PTA thresholds were unchanged after surgery. When the implant was activated, the mean PTA functional gain was 39 dB. The capability of the Carina MET Ossicular stimulator to provide appropriate gain relative to the degree of hearing loss indicates that the device offers a viable treatment option for mixed hearing loss. However, these promising initial results establish the need for future work on two fronts: (1) further studies are needed including a greater number of patients to confirm these preliminary results; (2) a long term follow-up must be carried out to detect any possible cochlear adverse effects on the cochlea, in particular on the basilar membrane.