Paradox of the Variation of the Bulk Resistance of Potassium Ion-Selective Electrode Membranes within Nernstian Potentiometric Response Range
Konstantin N Mikhelson
Russian Journal of Electrochemistry, 2019
View PDFchevron_right
Influence of silver salts in the polymer membrane of potassium-selective electrodes
Karl Cammann
Sensors and Actuators B: Chemical, 1994
View PDFchevron_right
An experimental study of membrane materials and inner contacting layers for ion-selective K+ electrodes with a stable response and good dynamic range
charlton kusi
Analytical Chemistry, 2004
View PDFchevron_right
Reference Electrodes with Polymer-Based Membranes—Comprehensive Performance Characteristics
Andrzej Lewenstam
Membranes
View PDFchevron_right
Effect of structure and properties of membrane active substance on analytical performance of ion-selective electrodes
Cecylia Wardak
Physicochemical Problems of Mineral Processing, 2019
View PDFchevron_right
An Operationally Defined Method for Ion Selective Electrode Studies: Potassium Selectivity of Polyvinyl Chloride Membranes
Signe Kjelstrup
Zeitschrift für Physikalische Chemie, 1994
View PDFchevron_right
Influence of Nonionic Surfactants on the Potentiometric Response of Ion-Selective Polymeric Membrane Electrodes Designed for Blood Electrolyte Measurements
Elzbieta Malinowska
Analytical Chemistry, 1998
View PDFchevron_right
The fabrication of potentiometric membrane sensors and their applications
Mohammad Yousefi
2010
View PDFchevron_right
Dependence of analytical parameters of ion-selective electrodes on the membrane solvents used in the construction of membranes
Anna Garbaty
Current Issues of Pharmacy and Medical Sciences, 2012
View PDFchevron_right
Potentiometric determination of coextraction constants of potassium salts in ion-selective electrodes utilizing a nitrobenzene liquid membrane phase
Debbie Silvester
View PDFchevron_right
A double-membrane ion-selective electrode for the potentiometric determination of potassium
Juan Vidal
Microchemical Journal, 1989
View PDFchevron_right
Factors Affecting the Potentiometric Response of All-Solid-State Solvent Polymeric Membrane Calcium-Selective Electrode for Low-Level Measurements
Andrzej Lewenstam
Analytical Chemistry, 2004
View PDFchevron_right
Electrically Enhanced Sensitivity (EES) of Ion-Selective Membrane Electrodes and Membrane-Based Ion Sensors
Andrzej Lewenstam
Membranes
View PDFchevron_right
Method of Achieving Desired Potentiometric Responses of Polyacrylate-Based Ion-Selective Membranes
Krystyna Pyrzyńska
Analytical Chemistry, 2008
View PDFchevron_right
Potentiometric response and mechanism of anionic recognition of heterocalixarene-based ion selective electrodes
Tatiana Shishkanova
Analytica Chimica Acta, 2007
View PDFchevron_right
A simple way to modify selectivity of sodium sensitive electrodes by using organic conductive crystals
Katarzyna Fendrych
Ionics, 2018
View PDFchevron_right
On the origin of the Hofmeister effect in anion-selective potentiometric electrodes with tetraalkylammonium salts
Kamil Wojciechowski
Journal of Electroanalytical Chemistry, 2010
View PDFchevron_right
A polyvinylchloride-membrane based anion selective electrode for continuous registration of ΔpH (interior alkaline) with salicylate as the indicator probe
Klaas Hellingwerf
Journal of Biochemical and Biophysical Methods, 1985
View PDFchevron_right
Performance Characteristics of Cells Containing Two Potentiometric Sensors: Application to a Cell Containing Hydralazinium and Chloride Electrodes
Adel Shoukry
International Journal of Chemistry, 2010
View PDFchevron_right
Selectivity of Potentiometric Ion Sensors
Philippe Bühlmann
Analytical Chemistry, 2000
View PDFchevron_right
Peer Reviewed: Polyion-Sensitive Membrane Electrodes for Biomedical Analysis
Mark Meyerhoff
Analytical Chemistry, 1996
View PDFchevron_right
A kinetic description of the membrane-solution interface for ion-selective electrodes
Bradford Pendley
ACS Sensors, 2020
View PDFchevron_right
Effect of Surfactants on the Electrochemical Performance of Cation-Selective Membrane Electrodes
Hakhyun Nam
Bulletin of the Korean Chemical Society
View PDFchevron_right
A tutorial on the application of ion-selective electrode potentiometry: An analytical method with unique qualities, unexplored opportunities and potential pitfalls; Tutorial
Bradford Pendley
Analytica Chimica Acta, 2013
View PDFchevron_right
Effect of pressure on the potentiometric response of ion-selective electrodes and reference electrodes
Beat Müller
Analytica Chimica Acta, 1996
View PDFchevron_right
Determination of potassium ion concentration in serum using a highly selective liquid-membrane electrode
Promise Koko
Clinica Chimica Acta, 1970
View PDFchevron_right
Ionic liquid-based reference electrodes for miniaturized ion sensors: What can go wrong?
Philippe Bühlmann
Sensors and Actuators B: Chemical, 2019
View PDFchevron_right
Non-constancy of the bulk resistance of ionophore-based ion-selective electrode: A result of electrolyte co-extraction or of something else?
Konstantin N Mikhelson
Electrochimica Acta, 2018
View PDFchevron_right
Problems and prospects of solid contact ion-selective electrodes with ionophore-based membranes
Konstantin N Mikhelson
Russian Chemical Bulletin, 2012
View PDFchevron_right
Investigation of Salicylate Interference on Anion Selective Electrodes *
Magdalena Maj-Żurawska
Analytical Letters, 2001
View PDFchevron_right
Potentiometric anion selectivity of polymer-membrane electrodes based on cobalt, chromium, and aluminum salens
Ibrahim Badr
Analytica Chimica Acta, 2006
View PDFchevron_right