Shear Wave Speed Measurement Using an Unfocused Ultrasound Beam (original) (raw)

Shear Wave Speed Measurement Using an Unfocused Ultrasound Beam

Ultrasound in Medicine & Biology, 2012

Tissue elasticity is related to pathology and therefore has important medical applications. Radiation force from a focused ultrasound beam has been used to produce shear waves in tissues for shear wave speed and tissue elasticity measurements. The feasibility of shear wave speed measurement using radiation force for an unfocused ultrasound beam is demonstrated in this study with a linear and a curved array transducer. Consistent measurement of shear wave speed was achieved over a relatively long axial extent (z = 10-40 mm for the linear array, and z = 15-60 mm for the curved array) in 3 calibrated phantoms with different shear moduli. In vivo measurements on the biceps of a healthy volunteer show consistent increase of shear wave speed for the biceps under 0, 1, 2, and 3 kg loading. Advantages and limitations of unfocused push are discussed.

Bias Observed in Time-of-Flight Shear Wave Speed Measurements Using Radiation Force of a Focused Ultrasound Beam

Ultrasound in Medicine & Biology, 2011

Measurement of shear wave propagation speed has important clinical applications because it is related to tissue stiffness and health state. Shear waves can be generated in tissues by the radiation force of a focused ultrasound beam (push beam). Shear wave speed can be measured by tracking its propagation laterally from the push beam focus using the time-of-flight principle. This study shows that shear wave speed measurements with such methods can be transducer, depth and lateral tracking range dependent. Three homogeneous phantoms with different stiffness were studied using curvilinear and linear array transducer. Shear wave speed measurements were made at different depths, using different aperture sizes for push and at different lateral distance ranges from the push beam. The curvilinear transducer shows a relatively large measurement bias that is depth dependent. The possible causes of the bias and options for correction are discussed. These bias errors must be taken into account to provide accurate and precise time-of-flight shear wave speed measurements for clinical use. (

Shear-wave generation using acoustic radiation force: in vivo and ex vivo results

Ultrasound in Medicine & Biology, 2003

Acoustic radiation force impulse (ARFI) imaging involves the mechanical excitation of tissue using localized, impulsive radiation force. This results in shear-wave propagation away from the region of excitation. Using a single diagnostic transducer on a modified commercial ultrasound (US) scanner with conventional beam-forming architecture, repeated excitations with multiple look directions facilitate imaging shear-wave propagation. Direct inversion methods are then applied to estimate the associated Young's modulus. Shear-wave images are generated in tissue-mimicking phantoms, ex vivo human breast tissue and in vivo in the human abdomen. Mean Young's modulus values of between 3.8 and 5.6 kPa, 11.7 kPa and 14.0 kPa were estimated for fat, fibroadenoma and skin, respectively. Reasonable agreement is demonstrated between structures in matched B-mode and reconstructed modulus images. Although the relatively small magnitude of the displacement data presents some challenges, the reconstructions suggest the clinical feasibility of radiation force induced shear-wave imaging. (

Assessment of shear modulus of tissue using ultrasound radiation force acting on a spherical acoustic inhomogeneity

IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 2000

An ultrasound-based method to locally assess the shear modulus of a medium is reported. The proposed approach is based on the application of an impulse acoustic radiation force to an inhomogeneity in the medium and subsequent monitoring of the spatio-temporal response. In our experimental studies, a short pulse produced by a 1.5-MHz highly focused ultrasound transducer was used to initiate the motion of a rigid sphere embedded into an elastic medium. Another 25 MHz focused ultrasound transducer operating in pulse-echo mode was used to track the displacement of the sphere. The experiments were performed in gel phantoms with varying shear modulus to demonstrate the relationship between the displacement of the sphere and shear modulus of the surrounding medium. Because the magnitude of acoustic force applied to sphere depends on the acoustic material properties and, therefore, cannot be used to assess the absolute value of shear modulus, the temporal behavior of the displacement of the sphere was analyzed. The results of this study indicate that there is a strong correlation between the shear modulus of a medium and spatio-temporal characteristics of the motion of the rigid sphere embedded in this medium.

Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics

Ultrasound in Medicine & Biology, 1998

Shear wave elasticity imaging (SWEI) is a new approach to imaging and characterizing tissue structures based on the use of shear acoustic waves remotely induced by the radiation force of a focused ultrasonic beam. SWEI provides the physician with a virtual "finger" to probe the elasticity of the internal regions of the body. In SWEI, compared to other approaches in elasticity imaging, the induced strain in the tissue can be highly localized, because the remotely induced shear waves are attenuated fully within a very limited area of tissue in the vicinity of the focal point of a focused ultrasound beam. SWEI may add a new quality to conventional ultrasonic imaging or magnetic resonance imaging. Adding shear elasticity data ("palpation information") by superimposing color-coded elasticity data over ultrasonic or magnetic resonance images may enable better differentiation of tissues and further enhance diagnosis. This article presents a physical and mathematical basis of SWEI with some experimental results of pilot studies proving feasibility of this new ultrasonic technology. A theoretical model of shear oscillations in soft biological tissue remotely induced by the radiation force of focused ultrasound is described. Experimental studies based on optical and magnetic resonance imaging detection of these shear waves are presented. Recorded spatial and temporal profiles of propagating shear waves fully confirm the results of mathematical modeling. Finally, the safety of the SWEI method is discussed, and it is shown that typical ultrasonic exposure of SWEI is significantly below the threshold of damaging effects of focused ultrasound. © 1998 World Federation for Ultrasound in Medicine & Biology.

Non-contact ultrasound shear wave generation and wave speed measurement in soft tissue

This study investigates the feasibility of non-contact ultrasound shear wave generation and detection using a line focused air-coupled transducer and miniaturized fiber optic-based Sagnac system for soft tissue mechanical characterization. This paper focused on the measuring ultrasound shear wave velocity on a phantom tissue surface. Different phantoms with different stiffness were used as samples. The group velocity and phase velocity of the generated ultrasound surface wave were measured. The results showed that the proposed system was efficient in ultrasound shear wave generation and detection. It has potential applications in non-contact and non-invasive soft tissue mechanical properties characterizations.

Acoustic Radiation Force-Induced Creep-Recovery (ARFICR): A Noninvasive Method to Characterize Tissue Viscoelasticity

IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2018

Ultrasound shear wave elastography is a promising noninvasive, low cost, and clinically viable tool for liver fibrosis staging. Current shear wave imaging technologies on clinical ultrasound scanners ignore shear wave dispersion and use a single group velocity measured over the shear wave bandwidth to estimate tissue elasticity. The center frequency and bandwidth of shear waves induced by acoustic radiation force depend on the ultrasound push beam (push duration, -number, etc.) and the viscoelasticity of the medium, and therefore are different across scanners from different vendors. As a result, scanners from different vendors may give different tissue elasticity measurements within the same patient. Various methods have been proposed to evaluate shear wave dispersion to better estimate tissue viscoelasticity. A rheological model such as the Kelvin-Voigt model is typically fitted to the shear wave dispersion to solve for the elasticity and viscosity of tissue. However, these rheolog...

Shearwave dispersion ultrasound vibrometry (SDUV) for measuring tissue elasticity and viscosity

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control, 2009

Characterization of tissue elasticity (stiffness) and viscosity has important medical applications because these properties are closely related to pathological changes. Quantitative measurement is more suitable than qualitative measurement (i.e., mapping with a relative scale) of tissue viscoelasticity for diagnosis of diffuse diseases where abnormality is not confined to a local region and there is no normal background tissue to provide contrast. Shearwave dispersion ultrasound vibrometry (SDUV) uses shear wave propagation speed measured in tissue at multiple frequencies (typically in the range of hundreds of Hertz) to solve quantitatively for both tissue elasticity and viscosity. A shear wave is stimulated within the tissue by an ultrasound push beam and monitored by a separate ultrasound detect beam. The phase difference of the shear wave between 2 locations along its propagation path is used to calculate shear wave speed within the tissue. In vitro SDUV measurements along and across bovine striated muscle fibers show results of tissue elasticity and viscosity close to literature values. An intermittent pulse sequence is developed to allow one array transducer for both push and detect function. Feasibility of this pulse sequence is demonstrated by in vivo SDUV measurements in swine liver using a dual transducer prototype simulating the operation of a single array transducer.