In Situ Ultrasonic Monitoring of Aluminum Ion Hydrolysis in Aqueous Solutions: Instrumentation, Techniques, and Comparisons to pH-Metry (original) (raw)
Related papers
Ultrasound Assisted Method to Increase the Aluminum Dissolve Rate from Acidified Water
World Academy of Science, Engineering and Technology, International Journal of Chemical, Molecular, Nuclear, Materials and Metallurgical Engineering, 2012
Aluminum salt that is generally presents as a solid phase in the water purification sludge (WPS) can be dissolved, recovering a liquid phase, by adding strong acid to the sludge solution. According to the reaction kinetics, when reactant is in the form of small particles with a large specific surface area, or when the reaction temperature is high, the quantity of dissolved aluminum salt or reaction rate, respectively are high. Therefore, in this investigation, water purification sludge (WPS) solution was treated with ultrasonic waves to break down the sludge, and different acids (1 N HCl and 1 N H2SO4) were used to acidify it. Acid dosages that yielded the solution pH of less than two were used. The results thus obtained indicate that the quantity of dissolved aluminum in H2SO4-acidified solution exceeded that in HCl-acidified solution. Additionally, ultrasonic treatment increased the rate of dissolution of aluminum and the amount dissolved. The quantity of aluminum dissolved at 60°...
International Journal of Chemical Studies, 2016
The batch adsorption studies were conducted to remove the fluoride from aqueous solutions using aluminium hydroxide (AHG) Aluminium hydroxide mono acetate (AHGMA) and Aluminium hydroxide di acetate (AHGDA) as adsorbents. Removal of fluoride was observed to be dependent on contact time, pH and adsorbent dose. The removal of fluoride was investigated at [F] = 3ppm, pH 6.6 and contact time 5 minutes on ultra-sonic bath, using adsorbent dose 0.01 to 0.1g per litre. The ultrasonic bath assisted defluoridation takes much lesser time as compared to conventional stirring. The % fluoride removal was found maximum in the pH range 5.5-6.5. The experimental data fitted well in the Freundlich adsorption isotherm, the curves between log (x/m) against log Ce were found linear with a positive intercept on the ordinate. The value of adsorption capacity K and the intensity of adsorption n, have been reported. The uptake of fluoride was found rapid and proportionate in initial stages, decreases gradua...
Use of ultrasonic baths for analytical applications: a new approach for optimisation conditions
Journal of the Brazilian Chemical Society, 2001
Com o emprego de um método simples e rápido, são propostas algumas condições de otimização para a obtenção de máxima intensidade de cavitação em banhos de ultra-som. Os parâmetros estudados foram: volume de água dentro do banho, temperatura, concentração de detergente, posição vertical e horizontal dos tubos no banho, número de tubos dentro do banho, tempo de sonicação e substituição da água do banho. Os resultados obtidos para os banhos de ultra-som estudados (Neytech e Cole-Parmer) permitiram estabelecer as seguintes condições para máxima intensidade de cavitação: 1 L de água à temperatura ambiente; 0,2 % (v/v) de detergente; posição central e ao fundo do banho. Somente 1 tubo deve ser usado por vez dentro do banho durante a aplicação do ultra-som. A intensidade de cavitação foi linear com o tempo de sonicação até 10 minutos e a substituição de água durante a sonicação melhorou a reprodutibilidade. Esse sistema de troca contínua de água permite a sonicação de até 6 amostras consecutivamente sem mudanças no volume total de água. Optimisation conditions for obtaining maximum cavitation intensity in ultrasonic baths are proposed using a simple and fast method. Parameters such as water volume, temperature, detergent concentration, horizontal and vertical positions, number of tubes in the bath, sonication time and bath water substitution were studied. The results obtained for both baths studied (Neytech and Cole-Parmer) lead to the following conditions for maximum cavitation intensity: 1 L of water at room temperature, 0.2 % (v/v) of detergent, central position on the bottom of the tank. Only one tube at a time should be used inside the bath during the ultrasound application. The cavitation intensity was linear with the sonication time up to 10 minutes and the water substitution during the sonication improved reproducibility. This system using continuous water change makes possible the sonication of 6 consecutive samples, without changes in the water volume.
Journal of Colloid and Interface Science, 2009
The sol-gel transformation of aqueous solutions of aluminium ions into aluminium (oxy)hydroxides induced by the addition of a 'soft base'-'Tris-buffer' (pK a = 8.2) has been investigated using monotonous single-batch titrations and a combination of four complimentary techniques for monitoring pH, conductivity, viscosity and ultrasound parameters (velocity and attenuation). The multi-probe monitoring of the formation of aluminium (oxy)hydroxides enabled important stages of the sol-gel transformation process including: the structural conversion of aluminium Keggin-like polynuclear clusters into nanoparticles of aluminium (oxy)hydroxide; the aggregation of primary nuclei of aluminium (oxy)hydroxide into larger particles, and the 'arrested growth' of the aggregates with the formation of the threedimensional gel network to be followed. The effect of aluminium ion molecular speciation on the sol-gel transformation stages is discussed. The data presented show that ultrasonic spectrometry, although a novel tool for sol-gel studies, is beneficial for the non-invasive monitoring of the latter stages of aluminium (oxy)hydroxide formation and its eventual breakdown in the presence of excess base.
Ultrasonic Measurements of Temperature in Aqueous Solutions: Why and How
Physics Research International, 2011
The paper describes two different approaches to ultrasonic measurements of temperature in aqueous solutions. The first approach uses two narrowband ultrasonic transducers and support electronics that form an oscillating sensor which output frequency is related to the measured temperature. This low-cost sensor demonstrated sensitivity of about 40 Hz/K at the distance of 190 mm and the operating frequency of about 25 kHz. The second approach utilised pulse-echo mode at the centre frequency of 20 MHz. The reflector featured a cavity that was filled with deionised water. The ultrasound propagation delay in the cavity was related to the temperature in the solution. The experiments were conducted for deionised water, and solutions of sodium persulfate, sodium chloride, and acetic acid with concentrations up to 0.5 M. In the experiments (conducted within the temperature range from 15 to 30°C), we observed increases in the ultrasound velocity for increased temperatures and concentrations as...
Understanding aluminum behaviour in aqueous alkaline solution using coupled techniques
Electrochimica Acta, 2010
This work focuses on the behaviour of pure aluminum in alkaline media, by coupling both acoustic emission (AE) and direct hydrogen voltammetry to electrochemistry. We notably monitored, recorded and analyzed the acoustic emission activity generated by the aluminum electrode as a function of its polarization during a linear sweep voltammetry (from anodic to cathodic potentials) on pure aluminum in 4 M aqueous potassium hydroxide solution. Such in situ coupling of electrochemistry and acoustic emission shows a perfect correlation between the two signals. After careful analysis of the AE signal using a statistical treatment, and based on five relevant AE parameters (rise time, duration, amplitude, absolute energy, maximum frequency), we could separate various groups of AE signals occurring at the aluminum electrode. We further linked them to the different (and possibly concomitant) electrochemical phenomena, which are taking place upon polarization of the aluminum electrode in strong alkaline medium.
Ultrasonic on-line spectrophotometric system for reaction kinetic measurements
Proceedings of the Estonian Academy of Sciences, 2012
A unique ultrasonic online spectrophotometric system for kinetic measurements of homogeneous polar reactions under ultrasound was developed. The setup consists of an ultrasonic bath, an HPLC UV/Vis detector, an HPLC pump, a refrigerated heating circulator bath, and a data processing unit. An analogue-digital converter was constructed and a data processing program AD_com was written for registration of detector signal. The pH-independent hydrolysis of 4-nitrophenyl chloroacetate as a model reaction and also sonolytic degradation of 4-nitrophenol were used for the examination of the online spectrophotometric system. Preliminary kinetic studies proved that the system can be successfully applied for ultrasonic kinetic investigations of polar homogeneous reactions. This online system allows a sensitive and reproducible monitoring of various homogeneous processes, which can be detected spectrophotometrically under ultrasonic irradiation.
Journal of Mass Spectrometry, 2014
Ultrasonication has been used to accelerate chemical reactions. It would be ideal if ultrasonication-assisted chemical reactions could be monitored by suitable detection tools such as mass spectrometry in real time. It would be helpful to clarify reaction intermediates/products and to have a better understanding of reaction mechanism. In this work, we developed a system for ultrasonication-assisted spray ionization mass spectrometry (UASI-MS) with an~1.7 MHz ultrasonic transducer to monitor chemical reactions in real time. We demonstrated that simply depositing a sample solution on the MHz-based ultrasonic transducer, which was placed in front of the orifice of a mass spectrometer, the analyte signals can be readily detected by the mass spectrometer. Singly and multiply charged ions from small and large molecules, respectively, can be observed in the UASI mass spectra. Furthermore, the ultrasonic transducer used in the UASI setup accelerates the chemical reactions while being monitored via UASI-MS. The feasibility of using this approach for real-time acceleration/monitoring of chemical reactions was demonstrated. The reactions of Girard T reagent and hydroxylamine with steroids were used as the model reactions. Upon the deposition of reactant solutions on the ultrasonic transducer, the intermediate/product ions are readily generated and instantaneously monitored using MS within 1 s. Additionally, we also showed the possibility of using this reactive UASI-MS approach to assist the confirmation of trace steroids from complex urine samples by monitoring the generation of the product ions.
Ultrasonic degradation of acetaminophen in water: Effect of sonochemical parameters and water matrix
Ultrasonics Sonochemistry, 2014
This paper deals about the sonochemical water treatment of acetaminophen (ACP, N-acetyl-p-aminophenol or paracetamol), one of the most popular pharmaceutical compounds found in natural and drinking waters. Effect of ultrasonic power (20-60 W), initial ACP concentration (33-1323 lmol L À1 ) and pH (3-12) were evaluated. High ultrasonic powers and, low and natural acidic pH values favored the efficiency of the treatment. Effect of initial substrate concentration showed that the Langmuir-type kinetic model fit well the ACP sonochemical degradation. The influence of organic compounds in the water matrix, at concentrations 10-fold higher than ACP, was also evaluated. The results indicated that only organic compounds having a higher value of the Henry's law constant than the substrate decrease the efficiency of the treatment. On the other hand, ACP degradation in mineral natural water showed to be strongly dependent of the initial substrate concentration. A positive matrix effect was observed at low ACP concentrations (1.65 lmol L À1 ), which was attributed to the presence of bicarbonate ion in solution.