Quality assurance of the international computerised 24 h dietary recall method (EPIC-Soft) (original) (raw)
Related papers
Respondents’ evaluation of the 24-h dietary recall method (EPIC-Soft) in the EFCOVAL Project
European Journal of Clinical Nutrition, 2011
Background: To improve participation rate, accuracy and respondents' compliance, it is important to know the respondents' viewpoint. Objective: To evaluate respondents' preferences and perception about the EPIC-Soft (the software developed to conduct 24-h dietary recalls (24-HDRs) in the European Prospective Investigation into Cancer and Nutrition (EPIC) Study) 24-HDR interviews and to compare these preferences and perception between population groups (for example, between genders). Design: Data were collected in Belgium, Czech Republic, France, the Netherlands and Norway in 2007. Two 24-HDRs (face-toface and telephone administered) were conducted using EPIC-Soft. An evaluation questionnaire on different study aspects was completed by the respondents. Setting: Data were collected in the European Food Consumption Validation Study. Subjects: A convenience sample of 600 apparently healthy men and women, 45-65 years old and including all educational levels, were recruited (120 subjects per country). Differences among population groups were compared by means of the w 2-test. Results: A total of 585 respondents completed the evaluation questionnaire. In all, 88% experienced problems only to a low degree when answering face-to-face and telephone-administered 24-HDR using EPIC-Soft. A total of 15% would have preferred help of another person during the face-to-face interview in the study center (mainly men: Po0.001). Significantly, more subjects in the Netherlands and in Norway preferred two telephone (instead of face-to-face) interviews compared with the other countries (Po0.001). Conclusion: Most subjects only experienced problems to a low degree during the EPIC-Soft interviews. Differences in preferences and capabilities to answer the EPIC-Soft interviews were identified between population groups (for example, gender differences). Therefore, the methods and the design to be used in a survey should be adapted according to the study population, so as to optimize response rate and compliance.
Public health nutrition, 2017
The present study describes the procedure and approaches needed to adapt and harmonise the GloboDiet methodology, a computer- and interview-based 24 h dietary recall, for use in two Latin American pilot countries, Brazil and Mexico. About seventy common and country-specific databases on foods, recipes, dietary supplements, quantification methods and coefficients were customised and translated following standardised guidelines, starting from existing Spanish and Portuguese versions. Brazil and Mexico. Not applicable. New subgroups were added into the existing common food classification together with new descriptors required to better classify and describe specific Brazilian and Mexican foods. Quantification methods were critically evaluated and adapted considering types and quantities of food consumed in these two countries, using data available from previous surveys. Furthermore, the photos to be used for quantification purposes were identified for compilation in country-specific bu...
Cadernos de Saúde Pública, 2016
The objective of this study was to assess the agreement between the Brazilian Healthy Eating Index – Revised (BHEI-R), estimated by a food frequency questionnaire (FFQ) and multiple 24-hour recalls (24h-R). The Wilcoxon paired test, partial correlations (PC), intraclass correlation coefficient (ICC), and Bland-Altman method were used. The total BHEI-R scores and its components (“total fruits”, “whole fruits”, “total vegetables”, “integral cereals”, “saturated fat”, “sodium”, and “energy intake derived from solid fat, added sugar, and alcoholic beverages”) were statistically different, with the ICC and PC indicating poor concordance and correlation. The mean concordance estimated for the total BHEI-R and its components varied from 68% for “integral cereals” to 147% for “whole fruits”. The suitable concordance limits were violated for most of the components of the BHEI-R. Poor concordance was observed between the BHEI-R estimated by the FFQ and by multiple 24h-R, which indicated a str...
Advances in Nutrition: An International Review Journal
Securing accurate measurements of dietary intake across populations is challenging. Of the methods, self-reported 24-h recalls are often used in low-income countries (LICs) because they are quick, culturally sensitive, do not require high cognitive ability, and provide quantitative data on both foods and nutrients. Measuring intakes via 24-h recalls involves 1) collecting data on food intakes, 2) the appropriate use of relevant foodcomposition data for calculating nutrient intakes, and 3) statistically converting observed intakes to "usual intakes" for evaluating nutrient adequacy or relations between foods and nutrients and health outcomes. Like all dietary methods, 24-h recalls are subject to random errors that lower the precision and systematic errors that can reduce accuracy at each stage of the measurement protocol. Research has identified the potential sources of measurement errors in 24-h recall protocols and emphasized that sources of random error can be reduced by incorporating standardized quality-control procedures and collecting more than one 24-h recall per person, with the number depending on the study objective. Careful design of the initial 24-h recall protocol can take into account potential sources of systematic error, such as day of the week, season, age, etc. Other sources of systematic error (e.g., energy underreporting) can best be detected by including a reference measure (e.g., doubly labeled water to measure energy expenditure). Alternatively, 24-h recall intakes of energy can be compared with same-day weighed intakes. Nevertheless, very few studies in LICs have assessed the validity of 24-h recalls in their study settings or adopted recommended standardized protocols to mitigate random errors. Hence, efforts should be made to improve the assessment, analysis, and interpretation of selfreported 24-h recall data for population studies in LICs. Accurate and precise dietary intake data at the national level can play an essential role in informing food, nutrition, and agricultural policies; food fortification planning; and compliance to food-based dietary guidelines. Adv Nutr 2017;8:980-91.
European Journal of Clinical Nutrition, 2000
Objectives: Despite increasing interest in the concept of calibration in dietary surveys, there is still little experience in the use and standardization of a common reference dietary method, especially in international studies. In this paper, we present the general theoretical framework and the approaches developed to standardize the computer-assisted 24 h diet recall method (EPIC-SOFT) used to collect about 37 000 24-h dietary recall measurements (24-HDR) from the 10 countries participating in the European Prospective Investigation into Cancer and Nutrition (EPIC). In addition, an analysis of variance was performed to examine the level of standardization of EPIC-SOFT across the 90 interviewers involved in the study. Methods: The analysis of variance used a random effects model in which mean energy intake per interviewer was used as the dependent variable, while age, body mass index (BMI), energy requirement, week day, season, special diet, special day, physical activity and the EPIC-SOFT version were used as independent variables. The analysis was performed separately for men and women. Results: The results show no statistical difference between interviewers in all countries for men and ®ve out of eight countries for women, after adjustment for physical activity and the EPIC-SOFT program version used, and the exclusion of one interviewer in Germany (for men), and one in Denmark (for women). These results showed an interviewer effect in certain countries and a signi®cant difference between gender, suggesting an underlying respondent's effect due to the higher under-reporting among women that was consistently observed in EPIC. However, the actual difference between interviewer and country mean energy intakes is about 10%. Furthermore, no statistical differences in mean energy intakes were observed across centres from the same country, except in Italy and Germany for men, and France and Spain for women, where the populations were recruited from areas scattered throughout the countries. Conclusion: Despite these encouraging results and the efforts to standardize the 24-HDR interview method, conscious or unconscious behaviour of respondents andaor interviewer bias cannot be prevented entirely. Further evaluation of the reliability of EPIC-SOFT measurements will be conducted through validation against independent biological markers (nitrogen, potassium).
2021
Background: Latin American countries show a fast-growing rate of non-communicable diseases (NCDs) and diet is a critical risk factor that must be properly assessed. Automated dietary assessment tools to collect 24-h dietary recalls (24HR) are lacking in Argentina. Objective: This study aimed to develop an open-access automated tool (MAR24) for collecting 24HR using a multiple pass method and a database containing foods and recipes commonly consumed in Argentina. Methods: MAR24 was developed based on data from 1,285 24HR provided by male and female participants aged 18 to 68 years from the six Argentinian geographical regions. The main structure and interface of the tool were designed using Visual Basic for Applications programming language in Excel Microsoft Office 365, integrating the five steps of the United States Department of Agriculture (USDA) Automated Multiple-Pass Method (AMPM) for the application of 24HR in Spanish. The tool underwent alpha testing and expert assessment to...
Journal of Nutritional Science, 2017
Self-administered web-based 24-h dietary recalls (24 hR) may save a lot of time and money as compared with interviewer-administered telephone-based 24 hR interviews and may therefore be useful in large-scale studies. Within the Nutrition Questionnaires plus (NQplus) study, the web-based 24 hR tool Compl-eat™ was developed to assess Dutch participants’ dietary intake. The aim of the present study was to evaluate the performance of this tool against the interviewer-administered telephone-based 24 hR method. A subgroup of participants of the NQplus study (20–70 years, n 514) completed three self-administered web-based 24 hR and three telephone 24 hR interviews administered by a dietitian over a 1-year period. Compl-eat™ as well as the dietitians guided the participants to report all foods consumed the previous day. Compl-eat™ on average underestimated the intake of energy by 8 %, of macronutrients by 10 % and of micronutrients by 13 % as compared with telephone recalls. The agreement b...