CARACYI~ISATION DE SOLUTIONS AQUEUSES DE GLUCIDES PAR ULTRASONS HAUTES FRÉQUENCES (original) (raw)

Caractérisation De Solutions Aqueuses De Glucides Par Ultrasons Hautes Fréquences

Le Journal de Physique IV, 1992

Le but de notre travail est de déterminer l'influence de la structure et de la concentration de glucides simples (oses) et composés (diholosides) sur l'atténuation ultrasonore de solutions contenant ce type de molécules. Les expériences montrent qu'il n'existe aucune différence d'atténuation entre une solution aqueuse de glucose (al

CARACTÉRISATION DU SANG PAR ULTRASONS HAUTES FRÉQUENCES

Le Journal de Physique IV, 1992

Our interest here is in the experimental determination of ultrasonic attenuation in blood as a function of its main components (plasma and erythrocytes) in the frequency range between 50 and 400 MHz at the room tem­ perature of 20°C. The originality of this work is that, with such high frequencies, the wavelengths become very close to the scatterers' (the erythrocytes)

f- RESULTATS DE Ci]YQ ANNEES D'AUSCULTATION SUR UN GLISSIMENT DANS LES ARGILES GLACIO-LACUSTRES DU TRIEVES (Sud-Est DE LA FRÀNCE)

Glacio-lacustrine varved clays of Trièves ar-si (South of Grenoble -France) has been extensively studied both for ùeir geliechnical characaerisrics and for rhe insrability phenomenons they give way. A combined gecderic and inclinometric monitoring is underway on a site which endanger public security, allowing a better understanding of the movement as well as a -. betaer approach of the way in which the slope failure may occur. In a superlicial zone (0 -12 m), as soon as the distorsion is over l-00 Vo ,clear cut kinematic discontinuities appear. A slip circle, which is 43 m deep, involves all the slope. Below, down at least to 50 m, one mây observe a deformation gradient rather than an accurately located failure surface, which may shear up to 40 m depth of soil n4sumé : Les argiles varvées glacio-lacustres du Trièves (au Sud de Grenoble -France) ont fait l'objet de nombreuses --herchqs relatives. à leurs caractéristiques géotechniques et aux manifestations d'instabilité qu&#3...

Elimination Des Metaux Lourds en Solution Aqueuse Par Des Argiles Algeriennes

2014

Conférences à l'université de Tlemcen à qui, J'adresse ma profonde reconnaissance pour son aide et son soutien, qu'il m'a apporté en vue de concrétiser ce travail. Mes vifs remerciements s'adressent à Monsieur Benamar MAKHOUKHI, Maître de Conférences à l'Université de Tlemcen, pour l'intérêt qu'il a porté à ce travail et pour nous avoir honoré de présider le jury de cette mémoire. Ma gratitude va à Madame Malika MOKHTARI, Professeur à l'Université de Tlemcen,pour avoir acceptée de participer à ce jury et pour son aide ainsi que ses conseils apportés. De même je tiens à remercier Monsieur Omar ABDERRAHIM, Maître de Conférences à l'Université de Tlemcen, pour avoir pris part à ce jury et pour son aide ainsi que ses conseils apportés.

DE LA MODÉLISATION À LA QUANTIFICATION PAR ULTRASONS DE L’AGRÉGATION ÉRYTHROCYTAIRE

2013

Many studies have reported that an enhanced level of red blood cell aggregation is associated with the presence of hemorheological disorders. Pathological aggregation has been characterized by quantitative ultrasound based on the backscattering coefficient. In order to describe the interaction between the incident ultrasound and the interrogated biological tissues, mathematical models are used. Mathematical modeling is known to be the optimal way to describe the interaction occurring between ultrasound and tissues at the cellular level. The structure factor model (SFM), considered as the exact scattering model has been developed to predict the backscattering coefficient from blood. However, the numerical SFM cannot be applied in real time for practical measurements and does not provide aggregate size to assess the level of aggregation. Therefore, we come up with a new model based on the effective medium theory in order to tackle this difficulty. The effective medium theory combined with the structure factor model (EMTSFM) can be applied in real time and contrary to the SFM provides two indices of the aggregate state in vivo: aggregate size and compactness. Based on a 3D simulation study, the backscattering coefficients (BSCs) predicted by the effective medium theory combined with the Structure Factor Model (EMTSFM) are compared to the BSCs computed with SFM. Our aim here is to assess the accuracy of the EMTSFM against the SFM by comparing their BSC in the framework of a forward problem, i.e., the calculation of the BSC from the known acoustic and structure aggregate parameters. This was done in order to validate the proposed model. To simulate aggregates, RBCs are stacked following a hexagonal close packing scheme. The influences of the aggregate radius and compactness on the BSC are studied as well. The results showed good agreement between the SFM and the EMTSFM based on our simulated microstructure of RBC aggregates. Our work provides thus the theoretical background to assess locally the aggregation level for diagnosis purposes.

ALOA2i : OPTIMISATION D'EXTRACTION DES K- ITEMSETS FREQUENTS (POUR K ≤ 2)

2016

Dans cet article, nous proposons une nouvelle approche d'optimisation de l'algorithme de reference APRIORI (AGR 94).La demarche utilisee est basee sur des ensembles a un et deux items. Nous commencons par calculer les supports des 1-itemsets (ensembles de singletons), ensuite nous elaguons les 1-itemsets non frequents et ne conservons que ceux qui sont frequents (c'est-a-dire ceux qui ont des frequences d'apparition appelees supports dont les valeurs sont superieures ou egales a un seuil minimal fixe).Pendant la deuxieme iteration, nous trions les 1-itemsets frequents par ordre decroissant de leurs supports respectifs puis nous formons les 2-itemsets. De cette facon les regles d'association sont decouvertes plus rapidement.Experimentalement, la comparaison de notre algorithme avec APRIORI, PASCAL, CLOSE et MAX-MINER, montre son efficacite sur des donnees faiblement correlees

ETUDE PAR DIFFRACTION DES RX ET MEB DE L’EVOLUTION DES COUCHES Zn-Ni ELECTRODEPOSEES SUR DE SUBSTRAT D’UN ACIER FAIBLEMENT ALLIE

2011

L'objectif de ce travail est d'étudier l'effet de certains facteurs tels que la concentration de nickel dans l'électrolyte, la température d'électrolyte et la densité de courant afin d'améliorer les propriétés mécaniques, morphologie de la surface de l'alliage zinc - nickel a été déposé sur une substrat de l'acier doux pour le protéger contre la corrosion en utilisant un bain de chlorure , et ont étudier leur comportement dans le milieu corrosif. L'utilisation de la diffraction de rayons X et le MEB nous a donné des informations sur la structure morphologique et cristalline de l'alliage a montré que la concentration de nickel dans l'électrolyte a joué un rôle important dans l'obtention d'alliage zinc - nickel de bonnes propriétés mécaniques et une haute résistance à la corrosion, à condition que pas plus de 25% à l'intérieur du bain électrolytique