An ultrasonication-assisted extraction and derivatization protocol for GC/TOFMS-based metabolite profiling (original) (raw)
Related papers
Quantitative metabolomics based on gas chromatography mass spectrometry: status and perspectives
Metabolomics, 2010
Metabolomics involves the unbiased quantitative and qualitative analysis of the complete set of metabolites present in cells, body fluids and tissues (the metabolome). By analyzing differences between metabolomes using biostatistics (multivariate data analysis; pattern recognition), metabolites relevant to a specific phenotypic characteristic can be identified. However, the reliability of the analytical data is a prerequisite for correct biological interpretation in metabolomics analysis. In this review the challenges in quantitative metabolomics analysis with regards to analytical as well as data preprocessing steps are discussed. Recommendations are given on how to optimize and validate comprehensive silylation-based methods from sample extraction and derivatization up to data preprocessing and how to perform quality control during metabolomics studies. The current state of method validation and data preprocessing methods used in published literature are discussed and a perspective on the future research necessary to obtain accurate quantitative data from comprehensive GC-MS data is provided.
Bioanalysis, 2014
Invasive, site-specific metabolite information could be better obtained from tissues. Hence, highly sensitive mass spectrometry-based metabolomics coupled with separation techniques are increasingly in demand in clinical research for tissue metabolomics application. Applying these techniques to nontargeted tissue metabolomics provides identification of distinct metabolites. These findings could help us to understand alterations at the molecular level, which can also be applied in clinical practice as screening markers for early disease diagnosis. However, tissues as solid and heterogeneous samples pose an additional analytical challenge that should be considered in obtaining broad, reproducible and representative analytical profiles. This manuscript summarizes the state of the art in tissue (human and animal) treatment (quenching, homogenization and extraction) for nontargeted metabolomics with mass spectrometry.
Analytical Chemistry, 2009
A method for the preparation and GC-TOF-MS analysis of human serum samples has been developed and evaluated for application in long-term metabolomic studies. Serum samples were deproteinized using 3:1 methanol/ serum, dried in a vacuum concentrator, and chemically derivatized in a two-stage process. Samples were analyzed by GC-TOF-MS with a 25 min analysis time. In addition, quality control (QC) samples were used to quantify process variability. Optimization of chemical derivatization was performed. Products were found to be stable for 30 h after derivatization. An assessment of within-day repeatability and within-week reproducibility demonstrates that excellent performance is observed with our developed method. Analyses were consistent over a 5 month period. Additional method testing, using spiked serum samples, showed the ability to define metabolite differences between samples from a population and samples spiked with metabolites standards. This methodology allows the continuous acquisition and application of data acquired over many months in long-term metabolomic studies, including the HUSERMET project (http://www.husermet.org/).
Analytical and Bioanalytical Chemistry, 2013
Reproducible and quantitative gas chromatographymass spectrometry (GC-MS)-based metabolomics analysis of complex biological mixtures requires robust and broadspectrum derivatization. We have evaluated derivatization of complex metabolite mixtures using trimethylsilyl cyanide (TMSCN) and the most commonly used silylation reagent Nmethyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA). For the comparative analysis, two metabolite mixtures, a standard complex mixture of 35 metabolites covering a range of amino acids, carbohydrates, small organic acids, phenolic acids, flavonoids and triterpenoids, and a phenolic extract of blueberry fruits were used. Four different derivatization methods, (1) direct silylation using TMSCN, (2) methoximation followed by TMSCN (M-TMSCN), (3) direct silylation using MSTFA, and (4) methoximation followed by MSTFA (M-MSTFA) were compared in terms of method sensitivity, repeatability, and derivatization reaction time. The derivatization methods were observed at 13 different derivatization times, 5 min to 60 h, for both metabolite mixtures. Fully automated sample derivatization and injection enabled excellent repeatability and precise method comparisons. At the optimal silylation times, peak intensities of 34 out of 35 metabolites of the standard mixture were up to five times higher using M-TMSCN compared with M-MSTFA. For direct silylation of the complex standard mixture, the TMSCN method was up to 54 times more sensitive than MSTFA. Similarly, all the metabolites detected from the blueberry extract showed up to 8.8 times higher intensities when derivatized using TMSCN than with MSTFA. Moreover, TMSCN-based silylation showed fewer artifact peaks, robust profiles, and higher reaction speed as compared with MSTFA. A method repeatability test revealed the following robustness of the four methods: TMSCN>M-TMSCN>M-MSTFA> MSTFA.
Analytical Chemistry, 2006
The aim of metabolite profiling is to monitor all metabolites within a biological sample for applications in basic biochemical research as well as pharmacokinetic studies and biomarker discovery. Here, novel data analysis software, XCMS, was used to monitor all metabolite features detected from an array of serum extraction methods, with application to metabolite profiling using electrospray liquid chromatography/mass spectrometry (ESI-LC/MS). The XCMS software enabled the comparison of methods with regard to reproducibility, the number and type of metabolite features detected, and the similarity of these features between different extraction methods. Extraction efficiency with regard to metabolite feature hydrophobicity was examined through the generation of unique feature density distribution plots, displaying feature distribution along chromatographic time. Hierarchical clustering was performed to highlight similarities in the metabolite features observed between the extraction methods. Protein extraction efficiency was determined using the Bradford assay, and the residual proteins were identified using nano-LC/MS/MS. Additionally, the identification of four of the most intensely ionized serum metabolites using FTMS and tandem mass spectrometry was reported. The extraction methods, ranging from organic solvents and acids to heat denaturation, varied widely in both protein removal efficiency and the number of mass spectral features detected. Methanol protein precipitation followed by centrifugation was found to be the most effective, straightforward, and reproducible approach, resulting in serum extracts containing over 2000 detected metabolite features and less than 2% residual protein. Interestingly, the combination of all approaches produced over 10 000 unique metabolite features, a number that is indicative of the complexity of the human metabolome and the potential of metabolomics in biomarker discovery.
Metabolomics, 2011
Reproducible quantification of metabolites in tissue samples is of high importance for characterization of animal models and identification of metabolic changes that occur in different tissue types in specific diseases. However, the extraction of metabolites from tissue is often the most labor-intensive and error-prone step in metabolomics studies. Here, we report the development of a standardized high-throughput method for rapid and reproducible extraction of metabolites from multiple tissue samples from different organs of several species. The method involves a bead-based homogenizer in combination with a simple extraction protocol and is compatible with state-ofthe-art metabolomics kit technology for quantitative and targeted flow injection tandem mass spectrometry. We analyzed different extraction solvents for both reproducibility as well as suppression effects for a range of different animal tissue types including liver, kidney, muscle, brain, and fat tissue from mouse and bovine. In this study, we show that for most metabolites a simple methanolic extraction is best suited for reliable results. An additional extraction step with phosphate buffer can be used to improve the extraction yields for a few more polar metabolites. We provide a verified tissue extraction setup to be used with different indications. Our results demonstrate that this high-throughput procedure provides a basis for metabolomic assays with a wide spectrum of metabolites. The developed method can be used for tissue extraction setup for different indications like studies of metabolic syndrome, obesity, diabetes or cardiovascular disorders and nutrient transformation in livestock. Keywords Mass spectrometry Á Tissue extraction Á High-throughput Á Quantification Á Complex diseases Á Food quality Werner Römisch-Margl and Cornelia Prehn contributed equally to this work.
Detection of polar metabolites through the use of gas chromatography-mass spectrometry
Methods in molecular biology (Clifton, N.J.), 2013
Gas chromatography-mass spectrometry (GC-MS) is a highly reproducible and sensitive analytical technique that has had significant use in the area of metabolite profiling. GC-MS is able to detect a wide variety of metabolites, with highly differing chemistries. In general, extracted biological samples are volatilized prior to separation on a capillary column with a stationary phase suited to the analysis of the compounds of interest. Separated compounds are eluted into a mass spectrometer equipped with an electron impact ionization source, thereby generating a quantifiable mass spectral fingerprint. This chapter describes a method for the trimethylsilyl derivatization of polar metabolites, followed by detection and relative quantification using a gas chromatograph coupled to a single quadrupole mass spectrometer. Using this method will enable the profiling of the greatest range of polar metabolites.
Liquid chromatography-mass spectrometry in metabolite profiling
BioFactors, 2008
Recent advances in the use of liquid chromatography-mass spectrometry for the study of metabolomics are reviewed. Sample preparations of biofluids and practical aspects of ultra-high pressure liquid chromatography are discussed. Applicability of different kinds of mass spectrometers for metabolite profiling is described. New tools-ion mobility spectroscopy and automated chip-based nanoelectrospray system with potentials to be applied in the metabolomics analysis are described.
Analytical Chemistry, 2009
Advanced metabolomics technologies are anticipated to permit the identification and quantification of metabolites at the whole-metabolome scale. Yet, most of the metabolites either remain unknown or cannot be identified unambiguously. Moreover, the present approaches suffer from inaccuracies in relative quantification because of sample preparation and matrix effects. Here we present Dual Labeling of Metabolites for Metabolome Analysis (DLEMMA) as a valuable tool, which with analogy to DNA array assays enables the identification and relative quantification of differential metabolites in a single sample. DLEMMA was demonstrated as an efficient method for reducing the number of possible chemical structures assigned that exhibit the same elemental composition. Its strength was exemplified by the discovery of 10 novel Tryptophan derivatives. Furthermore, employing DLEM-MA by feeding two Phenylalanine-labeled precursors, we could detect differential metabolites between transgenic and control plants. The accuracy of relative quantification is also enhanced since DLEMMA provides identical matrixes for both samples, thus avoiding the effects of different complex biological matrixes on electrospray ionization. Hence, DLEMMA will complement and contribute to the advancement of metabolomics technologies and boost metabolic pathway discovery in diverse organisms.