Treatment and Prevention of Staphylococcus epidermidis Experimental Biomaterial-Associated Infection by Bactericidal Peptide 2 (original) (raw)

Polymeric Coatings and Antimicrobial Peptides as Efficient Systems for Treating Implantable Medical Devices Associated-Infections

Polymers

Many infections are associated with the use of implantable medical devices. The excessive utilization of antibiotic treatment has resulted in the development of antimicrobial resistance. Consequently, scientists have recently focused on conceiving new ways for treating infections with a longer duration of action and minimum environmental toxicity. One approach in infection control is based on the development of antimicrobial coatings based on polymers and antimicrobial peptides, also termed as “natural antibiotics”.

Staphylococcus epidermidis in Biomaterial-Associated Infections

Biomaterials Associated Infection, 2012

ABSTRACT Coagulase-negative staphylococci, mainly Staphylococcus epidermidis, are currently the most frequent cause of hospital acquired infections in the USA. Mostly, but not exclusively, S. epidermidis infections are linked to the use of implanted medical devices like central venous catheters, prosthetic joints and heart valves, pacemakers, cardiac assist devices, cerebrospinal fluid shunts, and intraocular lenses. As new molecular techniques reveal that S. epidermidis are by no means the most prominent bacteria of the skin and mucous membrane flora, the implication is that S. epidermidis has specific virulence factors, which transforms this commensal bacterial species into one of the most successful pathogens in modern medicine. A vast array of specific attachment factors for native and host protein-modified device surfaces and the ability to accumulate in adherent multilayered biofilms appear to be vital for the success of S. epidermidis as a pathogen. Biofilm formation contributes to the ability of the organism to withstand the host’s innate and acquired immune defense mechanisms and to resist antimicrobial therapy, so that device removal is a regular feature for the treatment of S. epidermidis biomaterial-associated infection. Recent developments in the understanding of S. epidermidis virulence are reviewed in this chapter.

Microscopic detection of viable Staphylococcus epidermidis in peri-implant tissue in experimental biomaterial-associated infection, identified by bromodeoxyuridine incorporation

Infection and immunity

Infection of biomedical devices is characterized by biofilm formation and colonization of surrounding tissue by the causative pathogens. To investigate whether bacteria detected microscopically in tissue surrounding infected devices were viable, we used bromodeoxyuridine (BrdU), a nucleotide analogue that is incorporated into bacterial DNA and can be detected with antibodies. Infected human tissue was obtained postmortem from patients with intravascular devices, and mouse biopsy specimens were obtained from mice with experimental biomaterial infection. In vitro experiments showed that Staphylococcus epidermidis incorporated BrdU, as judged from staining of the bacteria with anti-BrdU antibodies. After incubation of bacteria with BrdU and subsequent staining of microscopic sections with anti-BrdU antibodies, bacteria could be clearly visualized in the tissue surrounding intravascular devices of deceased patients. With this staining technique, relapse of infection could be visualized ...

Engineered Chimeric Peptides as Antimicrobial Surface Coating Agents Towards Infection-Free Implants

ACS Applied Materials & Interfaces, 2016

Prevention of bacterial colonization and consequent biofilm formation remains a major challenge in implantable medical devices. Implant-associated infections are not only a major cause of implant failures but also their conventional treatment with antibiotics brings further complications due to the escalation in multidrug resistance to a variety of bacterial species. Owing to their unique properties, antimicrobial peptides (AMPs) have gained significant attention as effective agents to combat colonization of microorganisms. These peptides have been shown to exhibit a wide spectrum of activities with specificity to a target cell while having a low tendency for developing bacterial resistance. Engineering biomaterial surfaces that feature AMP properties, therefore, offer a promising approach to prevent implant infections. Here, we engineered a chimeric peptide with bifunctionality that both forms a robust solid-surface coating while presenting antimicrobial property. The individual domains of the chimeric peptides were evaluated for their solid-binding kinetics to titanium substrate as well as for their antimicrobial properties in solution. The antimicrobial efficacy of the chimeric peptide on the implant material was evaluated in vitro against infection by a variety of bacteria, including Streptococcus mutans, Staphylococcus. epidermidis, and Escherichia coli, which are commonly found in oral and orthopedic implant related surgeries. Our results demonstrate significant improvement in reducing bacterial *

Engineered Chimeric Peptides as Antimicrobial Surface Coating Agents toward Infection-Free Implants

ACS Applied Materials & Interfaces, 2016

Prevention of bacterial colonization and consequent biofilm formation remains a major challenge in implantable medical devices. Implant-associated infections are not only a major cause of implant failures but also their conventional treatment with antibiotics brings further complications due to the escalation in multidrug resistance to a variety of bacterial species. Owing to their unique properties, antimicrobial peptides (AMPs) have gained significant attention as effective agents to combat colonization of microorganisms. These peptides have been shown to exhibit a wide spectrum of activities with specificity to a target cell while having a low tendency for developing bacterial resistance. Engineering biomaterial surfaces that feature AMP properties, therefore, offer a promising approach to prevent implant infections. Here, we engineered a chimeric peptide with bifunctionality that both forms a robust solid-surface coating while presenting antimicrobial property. The individual domains of the chimeric peptides were evaluated for their solid-binding kinetics to titanium substrate as well as for their antimicrobial properties in solution. The antimicrobial efficacy of the chimeric peptide on the implant material was evaluated in vitro against infection by a variety of bacteria, including Streptococcus mutans, Staphylococcus. epidermidis, and Escherichia coli, which are commonly found in oral and orthopedic implant related surgeries. Our results demonstrate significant improvement in reducing bacterial *

Peptides as potent antimicrobials tethered to a solid surface: Implications for medical devices

Nature Precedings

Medical devices are an integral part of therapeutic management; despite their importance, they carry a significant risk of microbial infection. Bacterial attachment to a medical device is established by a single, multiplying organism, leading to subsequent biofilm formation. To date, no preventative measures have impacted the incidence of device-related infection. We report the bidirectional covalent coupling of an engineered cationic antimicrobial peptide (eCAP), WLBU2, to various biological surfaces is accomplished. These surfaces included (i) a carbohydrate-based gel matrix, (ii) a complex polymeric plastic bead, and (iii) a silica-calcium phosphate nanocomposite associated with bone reconstruction. WLBU2-conjugated surfaces are shown to retain potent antimicrobial activity related to bacterial surface adhesion. This study provides proof of principle that covalently coating laboratory and bone-regenerating materials with eCAPs has the potential for decreasing infection rates of i...

Antibacterial Peptide-Based Gel for Prevention of Medical Implanted-Device Infection

PLOS ONE, 2015

Implanted medical devices are prone to infection. Designing new strategies to reduce infection and implant rejection are an important challenge for modern medicine. To this end, in the last few years many hydrogels have been designed as matrices for antimicrobial molecules destined to fight frequent infection found in moist environments like the oral cavity. In this study, two types of original hydrogels containing the antimicrobial peptide Cateslytin have been designed. The first hydrogel is based on alginate modified with catechol moieties (AC gel). The choice of these catechol functional groups which derive from mussel's catechol originates from their strong adhesion properties on various surfaces. The second type of gel we tested is a mixture of alginate catechol and thiol-terminated Pluronic (AC/Plu-bisSH), a polymer derived from Pluronic, a well-known biocompatible polymer. This Plu-bisSH polymer has been chosen for its capacity to enhance the cohesion of the composition. These two gels offer new clinical uses, as they can be injected and jellify in a few minutes. Moreover, we show these gels strongly adhere to implant surfaces and gingiva. Once gelled, they demonstrate a high level of rheological properties and stability. In particular, the dissipative energy of the (AC/PlubisSH) gel detachment reaches a high value on gingiva (10 J.m-2) and on titanium alloys (4 J.m-2), conferring a strong mechanical barrier. Moreover, the Cateslytin peptide in hydrogels exhibited potent antimicrobial activities against P. gingivalis, where a strong inhibition of bacterial metabolic activity and viability was observed, indicating reduced virulence. Gel biocompatibility tests indicate no signs of toxicity. In conclusion, these new hydrogels could be ideal candidates in the prevention and/or management of periimplant diseases.

Antimicrobial peptides on calcium phosphate-coated titanium for the prevention of implant-associated infections

Biomaterials, 2010

Prevention of implant-associated infections has been one of the main challenges in orthopaedic surgery. This challenge is further complicated by the concern over the development of antibiotic resistance as a result of using traditional antibiotics for infection prophylaxis. The objective of this study was to develop a technique that enables the loading and local delivery of a unique group of cationic antimicrobial peptides (AMP) through implant surfaces. A thin layer of micro-porous calcium phosphate (CaP) coating was processed by electrolytic deposition onto the surface of titanium as the drug carrier. The broad spectrum AMP Tet213 (KRWWKWWRRC) was selected and loaded onto the CaP coating. SEM, XRD and FTIR analyses confirmed the CaP coating to be micro-porous octacalcium phosphate. By using a luminescence spectrometer technique, it was demonstrated that a 7 mm thick porous CaP coating could load up to 9 mg of AMP/cm 2 using a simple soaking technique. The drug-loaded CaP coating (CaP-Tet213) was not cytotoxic for MG-63 osteoblast-like cells. The CaP-Tet213 implants had antimicrobial activity against both Gram-positive (Staphylococcus aureus) and Gram-negative (Pseudomonas aeruginosa) bacteria with 10 6 -fold reductions of both bacterial strains within 30 min as assessed by measuring colony-forming units (CFU). Repeated CFU assays on the same CaP-Tet213 specimen demonstrated retention of antimicrobial activity by the CaP-Tet213 surfaces through four test cycles. The susceptibility of bacteria to the CaP-Tet213 surfaces was also evaluated by assessing the inhibition of luminescence of P. aeruginosa containing a luxCDABE cassette at 4 h and 24 h with w92% and w77% inhibition of luminescence, respectively. It was demonstrated that CaP-Tet213 was a more efficient antimicrobial coating than CaP-MX226, CaP-hLF1-11 or CaP-tobramycin following incubation of CaP implants with equimolar concentrations of Tet213, the commercially developed antimicrobial peptide MX-226, hLF1-11 or tobramycin. A device coated with CaP-Tet213 could be a potential solution for the prevention of the periimplant infection in orthopaedics.

Membrane perturbation, altered morphology and killing of Staphylococcus epidermidis upon contact with a cytocompatible peptide-based antibacterial surface

Colloids and Surfaces B: Biointerfaces, 2021

This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

Repeatedly Applied Peptide Film Kills Bacteria on Dental Implants

JOM

The rising use of titanium dental implants has increased the prevalence of peri-implant disease that shortens their useful life. A growing view of periimplant disease suggests that plaque accumulation and microbiome dysbiogenesis trigger a host immune inflammatory response that destroys soft and hard tissues supporting the implant. The incidence of peri-implant disease is difficult to estimate, but with over 3 million implants placed in the USA alone, and the market growing by 500,000 implants/year, such extensive use demands additional interceptive approaches. We report a water-based, nonsurgical approach to address peri-implant disease using a bifunctional peptide film, which can be applied during initial implant placement and later reapplied to existing implants to reduce bacterial growth. Bifunctional peptides are based upon a titanium binding peptide (TiBP) optimally linked by a spacer peptide to an antimicrobial peptide (AMP). We show herein that dental implant surfaces covered with a bifunctional peptide film kill bacteria. Further, using a simple protocol for cleaning implant surfaces fouled by bacteria, the surface can be effectively recoated with TiBP-AMP to regain an antimicrobial state. Fouling, cleansing, and rebinding was confirmed for up to four cycles with minimal loss of binding efficacy. After fouling, rebinding with a waterbased peptide film extends control over the oral microbiome composition, providing a novel nonsurgical treatment for dental implants.