Low volume, large force (> 1mN) and nanometer resolution, electrostatic microactuator for low displacement applications (original) (raw)
Related papers
Viscosity measurements of PEO solutions by AFM with long nanowires
Long, constant diameter nanowires on the end of atomic force microscope (AFM) probes are expected to provide clean force distance (F-D) measurements that are easily interpretable. For measurements of the viscosity of low molecular weight liquids this proves to be true. Comparable values are found for glycerol when the nanowire is drawn from the liquid at a constant velocity over microns in scan length and when the nanowire insertion depth changes no more than that due to thermal Brownian vibration fluctuations, as is used for the Q damping measurement method-which also matches macroscopic viscometry methods. However, for measurements of the high molecular weight random chain polymer poly(ethylene oxide) (PEO) the differences are dramatic, with the Q damping method giving values that are orders of magnitude smaller than the linear drag force measurement. Since the deflection amplitude is sub-nanometer, the unusually low viscosity might be due to displacements that are smaller than the entanglement length of the polymer. Additional preliminary investigations are reported that do show somewhat increased viscosity with 10X increased vibration amplitude. Also time dependence of the measurements appears to be related to adsorption of monolayer coatings of PEO on the needle.
Multiband Microwave Transmitter for Electromagnetic Waves Propagation Study
2013
Master’s thesis describes the design of multi-band microwave transmitters to study the propagation of electromagnetic waves in the atmosphere with the possibility of modulation of the transmitted signal. Based transmitters are synchronized phase lock loop, frequency multipliers, double balanced diode mixers
Chemicke Listy, 2013
Rukopis byl zařazen k tisku v rámci placené služby urychleného publikování. Klíčová slova: kapilární elektromigrační metody, ionizační techniky, rozhraní, hmotnostní spektrometrie Obsah 1. Úvod 2. Ionizační techniky pro spojení CE-MS 2.1. Chemická ionizace za atmosférického tlaku 2.2. Fotoionizace za atmosférického tlaku 2.3. Ionizace elektrosprejem 2.4. Desorpční ionizace elektrosprejem 2.5. Přímá analýza v reálném čase 2.6. Ionizace laserem za účasti matrice 3. Rozhraní pro spojení CE-ESI-MS 3.1. Rozhraní bez přídavné kapaliny 3.2. Kapalinový spoj 3.3. Rozhraní s přídavnou kapalinou 4. Závěr
Návrh lávek pro pěší s nosnou konstrukcí z patinujících ocelí
2011
Cílem této diplomové práce je navrhnou projekt lávky pro pěší s nosnou konstrukcí z patinující oceli. Lávka je oblouková trámová se dvěma nosnými příhradovými trámy a dolní mostovkou. Diplomová práce se zabývá návrhem nosné konstrukce, výpočtem zatížení a posouzením jednotlivých prvků nosné konstrukce a vybraných detailů. Součástí diplomové práce je i rešerše využití patinujících ocelí na konstrukce lávek. Klíčová slova: Lávka pro pěší, patinující ocel Annotation: The objective of this diploma thesis is design of footbridge made of weathering steel. Supporting structure of footbridge is made of two arch trusses and roadway below. The diploma thesis describes design of footbridge, load calculation and assessement of truss members and selected details. Part of the diploma thesis is background research of possibilities of usage of weathering steels for footbridges' constructions
Modern microsurgery as a permanent, safe and gentle solution of unruptured intracranial aneurysms
Ceska A Slovenska Neurologie A Neurochirurgie, 2019
Modern microsurgery as a permanent, safe and gentle solution of unruptured intracranial aneurysms Souhrn Cíl: Nekrvácející mozkové výdutě (unruptured intracranial aneurysms; UIA) se vzhledem ke stoupající dostupnosti a lepší kvalitě zobrazovacích metod stávají stále častější dia gnózou v neurologické a neurochirurgické praxi. Vzhledem k existenci rizika ruptury a krvácení, je na místě zvážit jejich uzávěr. Na indikaci vyřazení výdutě z cirkulace a způsob vyřazení nejsou zcela jednotné názory. Prezentujeme výsledky pacientů s UIA operovaných na našem oddělení v průběhu posledních 9 let a náš pohled na tuto problematiku. Soubor a metodika: Pacienti s UIA operovaní na našem oddělení byli zahrnuti do souboru, který jsme retrospektivně analyzovali s důrazem na hodnocení bezpečnosti výkonu a úplnosti vyřazení výdutě. Výsledky: Za 9 let bylo operováno 146 pacientů se 184 incidentálními nebo koincidentálními výdutěmi. Nejčastěji byly výdutě lokalizovány na střední mozkové tepně (40 %). Perioperační komplikace se vyskytly u 10 % pacientů a celková chirurgická morbidita/ mortalita byla 3,5/ 0 %. U 143 pacientů byla provedena kontrolní CTA, která potvrdila úplnou obliteraci výdutě v 99 %. Průměrný follow-up pacientů byl 4,5 roku. Závěr: Naše výsledky ukazují, že mikrochirurgická léčba UIA je bezpečnou, dlouhodobě účinnou léčbou, dobře tolerovanou pacienty. Zejména v případě UIA, kde hlavním smyslem léčebné intervence je trvalá eliminace rizika krvácení, by měla být vždy zvažována jako léčebná modalita.
Design of clamping device for tubular conductors
2019
This bachelor thesis is focused on design of clamping device, which is a part of welding positioners for welding of aluminum tube conductors in ABB company. In the theoretical part, there are individual requirements of clamping devices with examples of their applications. The practical part is focused on the design of individual parts that meet the requirements for tube conductors and the functionality of the clamping system for arc welding of alluminium alloys